RCCB (Residual Current Circuit Breakers)
178 parts
Residual current circuit breakers (RCCB) from ABB, Siemens and Schneider Electric protect people and installations against earth leakage on DIN-rail panels. The range includes F200, FH200, 5SV3, 5SV5, Acti 9 iID and Easy9 Pro in 2-pole, 4-pole and 1+N versions, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes.
178 parts
Showing 1–48A9R61440 iIDSchneider Electric · Acti9 iID · iID 4P 40A Residual Current Circuit Breaker (RCCB) Acti9
2CSF204001R1630 F204 AC-63/0.03ABB · F200 · F204 AC-63/0.03 4P 63A 30mA Type AC Residual Current Circuit Breaker
2CSF202201R3630 F202 A S-63/0.3ABB · F200 · F202 A S-63/0.3 2P 63A 300mA Type A Residual Current Circuit Breaker
2CSF202201R3400 F202 A S-40/0.3ABB · F200 · F202 A S-40/0.3 2P 40A 300mA DIN-Rail Residual Current Circuit Breaker (RCCB)
2CSF204001R3950 F204 AC-125/0.3ABB · F200 · F204 AC-125/0.3 4P 125A 300mA 10kA Residual Current Circuit Breaker
2CSF204001R3800 F204 AC-80/0.3ABB · F200 · F204 AC-80/0.3 4P 80A Residual Current Circuit Breaker (RCCB) DIN Rail
5SV5646-6 5SV5Siemens · 5SV5 63A 4P 400V Residual Current Device
5SV5644-6 5SV5Siemens · 5SV5 40A 4P 400V Residual Current Device
5SV5642-6 5SV5Siemens · 5SV5 25A 4P 400V Residual Current Device
5SV5616-6 5SV5Siemens · 5SV5 63A 2P 230V Residual Current Device
5SV5614-6 5SV5Siemens · 5SV5 40A 2P 230V Residual Current Device
5SV5612-6 5SV5Siemens · 5SV5 25A 2P 230V Residual Current Device
5SV5346-6 5SV5Siemens · 5SV5 63A 4P 400V Residual Current Device
5SV5344-6 5SV5Siemens · 5SV5 40A 4P 400V Residual Current Device
5SV5342-6 5SV5Siemens · 5SV5 25A 4P 400V Residual Current Device
5SV5316-6 5SV5Siemens · 5SV5 63A 2P 230V Residual Current Device
5SV5314-6 5SV5Siemens · 5SV5 40A 2P 230V Residual Current Device
5SV5312-6 5SV5Siemens · 5SV5 25A 2P 230V Residual Current Device
5SV3648-6 5SV3Siemens · 5SV3 100A 4P 400V Residual Current Device
5SV3647-8 5SV3Siemens · 5SV3 80A 4P 400V Residual Current Device
5SV3647-6 5SV3Siemens · 5SV3 80A 4P 400V Residual Current Device
5SV3647-4 5SV3Siemens · 5SV3 80A 4P 400V Residual Current Device
5SV3646-8 5SV3Siemens · 5SV3 63A 4P 400V Residual Current Device
5SV3646-6 5SV3Siemens · 5SV3 63A 4P 400V Residual Current Device
5SV3646-4 5SV3Siemens · 5SV3 63A 4P 400V Residual Current Device
5SV3645-6 5SV3Siemens · 5SV3 125A 4P 400V Residual Current Device
5SV3644-8 5SV3Siemens · 5SV3 40A 4P 400V Residual Current Device
5SV3644-6 5SV3Siemens · 5SV3 40A 4P 400V Residual Current Device
5SV3644-4 5SV3Siemens · 5SV3 40A 4P 400V Residual Current Device
5SV3642-8 5SV3Siemens · 5SV3 25A 4P 400V Residual Current Device
5SV3642-6 5SV3Siemens · 5SV3 25A 4P 400V Residual Current Device
5SV3642-4 5SV3Siemens · 5SV3 25A 4P 400V Residual Current Device
5SV3626-4 5SV3Siemens · 5SV3 63A 2P 230V Residual Current Device
5SV3624-4 5SV3Siemens · 5SV3 40A 2P 230V Residual Current Device
5SV3622-4 5SV3Siemens · 5SV3 25A 2P 230V Residual Current Device
5SV3621-4 5SV3Siemens · 5SV3 16A 2P 230V Residual Current Device
5SV3617-8 5SV3Siemens · 5SV3 80A 2P 230V Residual Current Device
5SV3617-6 5SV3Siemens · 5SV3 80A 2P 230V Residual Current Device
5SV3616-8 5SV3Siemens · 5SV3 63A 2P 230V Residual Current Device
5SV3616-6 5SV3Siemens · 5SV3 63A 2P 230V Residual Current Device
5SV3614-8 5SV3Siemens · 5SV3 40A 2P 230V Residual Current Device
5SV3614-6 5SV3Siemens · 5SV3 40A 2P 230V Residual Current Device
5SV3612-8 5SV3Siemens · 5SV3 25A 2P 230V Residual Current Device
5SV3612-6 5SV3Siemens · 5SV3 25A 2P 230V Residual Current Device
5SV3348-6 5SV3Siemens · 5SV3 100A 4P 400V Residual Current Device
5SV3347-6 5SV3Siemens · 5SV3 80A 4P 400V Residual Current Device
5SV3347-4 5SV3Siemens · 5SV3 80A 4P 400V Residual Current Device
Can't find the part you need?
Send the part numbers or the specs you need. We reply with price, stock and dispatch time per line.
RCCB (Residual Current Circuit Breakers) buying guide
What's in this range
- ABB F200 and FH200 series in Type AC, A and B, including high-current versions up to 125 A.
- Siemens SENTRON 5SV3 and 5SV5 devices in 2P and 4P, 230 V and 400 V.
- Schneider Electric Acti 9 iID and Easy9 RCCBs.
- Type B devices for drive circuits.
How to choose
- Rated current: at least the total load current of the downstream circuits.
- Sensitivity: 30 mA for personal protection, 300 mA for fire protection or as a selective upstream device.
- Type: AC for resistive loads, A for electronics, B for drives and inverters.
- Short-circuit protection: an RCCB has none. Pair it with an upstream MCB or fuse.
- Poles: 2P for single-phase, 4P for three-phase with neutral.
RCCB (Residual Current Circuit Breakers) questions
Can an RCCB replace an MCB?
No. An RCCB does not trip on overload or short circuit. It must be protected by an upstream MCB or fuse.
What does Type A mean on an RCCB?
Type A detects sinusoidal AC and pulsating DC residual currents. Type AC detects sinusoidal AC only.
Can I order RCCBs for a project in bulk?
Yes. Request a quote with the part numbers and quantities. Stoklink ships from Turkey, EXW.