The Schneider Electric PAS600 EcoStruxure Panel Server is a universal gateway that connects wired Modbus devices and wireless PowerTag sensors to edge software or cloud applications. It bridges up to 32 Modbus RTU and 128 Modbus TCP/IP devices, plus up to 85 wireless IEEE 802.15.4 devices, over dual Ethernet, RS485 and Wi-Fi/Bluetooth, powered from a 110-277 V AC/DC supply.
The PAS600 is the entry-level Panel Server: a Modbus/wireless gateway with real-time monitoring web pages but no onboard long-term data logger, which keeps it suited to switchboards where measurements only need to reach a PME, BMS or SCADA system rather than be stored locally. Its 110-277 V AC/DC supply fits standard auxiliary circuits; the PAS600L variant is the same gateway built for a 24 V DC control bus instead. Step up to the PAS800 when three years of onboard historical trending and dashboarding is needed on the device itself.
| Range | EcoStruxure |
|---|---|
| Product name | Panel Server Universal |
| Product or Component Type | Gateway |
| Device short name | PAS600 |
| Device Application | Gateway |
| [Us] rated supply voltage | 110...277 V AC 50/60 Hz, 110...277 V DC |
| Communication gateway | Ethernet TCP/IP to wireless devices, Ethernet/serial |
| Product Compatibility | Wireless access point |
|---|---|
| Maximum power consumption in W | HW V2: 3.5 W 110...277 V, HW V1: 3 W 110...277 V |
| Maximum power consumption in VA | HW V2: 12 VA at 110...277 V, HW V1: 10 VA at 110...277 V |
| Communication network type | HW V2: Wi-Fi infrastructure5 GHz, HW V2: Wi-Fi infrastructure2.4 GHz, HW V1: Wi-Fi infrastructure 10/100BASE-T2.4 GHz, Ethernet 10/100BASE-T2.4 GHz, Wi-Fi access point IEEE 802.15.42.4 GHz, Wireless IEEE 802.15.4 even/odd or none parity 1.2...115.2 kbit/s, Modbus RTU Modbus RTU client even/odd or none parity 1.2...115.2 kbit/s |
| Communication port protocol | Modbus TCP, DHCP, HTTPS, NTP/SNTP, IPv4, IPv6, TCP/IP |
| Communication port support | 2 RJ45 ETHERNET, Screw terminal block RS485 |
| Number of server device(s) | 32 Modbus RTU product(s), 128 Modbus TCP/IP product(s), 40 wireless (IEEE 802.15.4) product(s) - mixed, 85 wireless (IEEE 802.15.4) product(s) - depending on configuration |
| Number of devices | 64 Modbus TCP/IP |
| Memory capacity | HW V2: 32 GB eMMC, HW V1: 512 MB NAND |
| Number of inputs | 0 |
| Connections - terminals | Power supply screw terminal block top) 0.002…0.004 in² (1.5…2.5 mm²), Communication screw terminal block bottom) 0.0002…0.002 in² (0.14…1.5 mm²) |
| Tightening torque | Power supply: 5.3 lbf.in (0.6 N.m), Communication: 2.21 lbf.in (0.25 N.m) |
| Wire stripping length | Power supply: 0.3 in (7 mm), Communication: 0.3 in (7 mm) |
| Number of connectors | HW V2: 2 screw connector for Wi-Fi and IEEE 802.15.4, HW V1: 1 screw connector for Wi-Fi |
| Connector type | HW V2: connector(s)1 x RP-SMA Wi-Fi for antenna bottom, HW V2: connector(s)1 x RP-SMA IEEE 802.15.4 for antenna top, HW V1: connector(s)1 x RP-SMA Wi-Fi for antenna bottom |
| Mounting Mode | Clip-on |
| Mounting Support | DIN rail |
| Product Certifications | CE, cULus, CB, RCM, UKCA, FCC, IC, DNV Marine, ANSI RF, IACS E10 |
| Standards | IEC 61010, IEC 61010-1, IEC 61010-2-201, UL 61010, UL 61010-1, UL 61010-2-201, EN 61010-1, EN 61010-2-201, CAN/CSA C22.2 No. 61010-1-12, CAN/CSA C22.2 No. 61010-2-201, IEC 62974-1, IEC 61326-1, EN 61326-1, ETSI EN 301 489-1, ETSI EN 301 489-17, EN 301-893, EN 55032, CISPR 11, ETSI EN 300 328, IEEE 802.15.4, IEEE 802.11a/b/g/n, IEEE 802.3 af/at, FCC CFR 47 part 15 class A, EN 62311, IEC 62311, ANSI C63.10, IEC 60945, EN 62974-1, DNVGL-GC-0339 |
| Depth | 2.8 in (70.2 mm) |
| Height | 3.7 in (93 mm) |
| Width | 2.8 in (72 mm) |
| Net Weight | 7.09 oz (201 g) |
| Data recording | Real time data monitoring |
| Data buffer for data publication (cloud, SFTP, HTTPS) depending on network | 1 month(s) |
| Function Available | Embedded web page for configuration and upgrade, Diagnosis capabilities, Diagnostic report, Diagnostics on communication, Energy management, With integrated web server, Firmware update, Backup/restore configuration, Configurable event |
| Product Specific Application | Wireless Schneider Electric devices ecosystem |
| Topology | Separated Ethernet network, Switched Ethernet network |
| Web services | HTTPS server, SFTP publication (CSV / JSON), HTTPS publication (CSV / JSON) |
| Communication Service | Device Profile for Web Services (DPWS), Modbus TCP client, Modbus TCP server, SNTP client, DHCP client, RSTP |
| Commissioning interface | EcoStruxure Power Commission desktop, EcoStruxure Power Commission Mobile (through Wi-Fi Access point), EcoStruxure Power Commission web (for third party device integration), Web page |
| Realtime clock | With RTC-battery set, With user calibration |
| Time synchronisation protocol | NTP, SNTP |
| Range compatibility | EcoStruxure Facility Expert, EcoStruxure Building Operation, EcoStruxure Power Operation, EcoStruxure Power Monitoring Expert, EcoStruxure Asset Advisor, EcoStruxure Energy Hub, EcoStruxure Resource Advisor, Third party SCADA |
| Communication iinterface | Modbus and wireless (IEEE802.15.4) product |
| Relative humidity | 5…95 % |
|---|---|
| IP degree of protection | IP40 front face), IP20 casing) |
| Ambient air temperature for operation | -13…158 °F (-25…70 °C) |
| Ambient Air Temperature for Storage | -40…185 °F (-40…85 °C) |
| Pollution degree | 2 |
| Operating altitude | < 6561.68 ft (2000 m) |
| Part number | PAS600 |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606481014344 |
| Warranty (in months) | 18 |
|---|
| Country of origin | IN |
|---|---|
| Shipping weight | 0.201 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of PAS600 is 110–277–DC V DC.
The tariff (HS) code on file for PAS600 is 851762.
The EAN (GTIN) of PAS600 is 3606481014344.
PAS600 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.