Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
The Schneider Electric CAD50AM7 is a TeSys Deca control relay with a 5 NO contact composition, rated 10 A Ith at up to 690 V AC, and a 220 V AC 50/60 Hz control circuit. It switches electromagnetic loads in AC-15 and DC-13 duty and wires into the control circuit of a motor starter or automation panel through snap-in terminals.
Pick the CAD50AM7 where the panel needs 5 NO switching in one block — the 50/60 Hz AC coil matches a standard control transformer secondary already present in most panels. The snap-in wiring style is the other variant axis in this family: snap-in terminals wire without tools, which speeds up panel assembly on repeat builds. At 10 A Ith and a 100 A / 1 s short-time withstand, the CAD50AM7 is sized for auxiliary and interlock duty alongside a main contactor, not as the load-switching device itself.
| Range | TeSys |
|---|---|
| Product name | TeSys CAD |
| Product or component type | Control relay |
| Device short name | CAD |
| Contactor application | Control circuit |
| Utilisation category | AC-15, AC-14, DC-13 |
|---|---|
| Pole contact composition | 5 NO |
| [Ue] rated operational voltage | <= 690 V AC 25...400 Hz |
| Control circuit type | AC 50/60 Hz |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Irms rated making capacity | 140 A AC, 250 A DC |
| [Icw] rated short-time withstand current | 100 A - 1 s, 120 A - 500 ms, 140 A - 100 ms |
| Associated fuse rating | 10 A gG conforming to IEC 60947-5-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1 |
| Mounting support | Rail, Plate |
| Connections - terminals | Snap-in terminal 1 cable(s) 0.5…4 mm²flexible without cable end, Snap-in terminal 2 cable(s) 0.5…4 mm²flexible without cable end, Snap-in terminal 1 cable(s) 0.5…2.5 mm²flexible with cable end, Snap-in terminal 2 cable(s) 0.5…2.5 mm²flexible with cable end |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz, 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Operating time | 4...19 ms coil energisation and NC opening, 12...22 ms coil energisation and NO closing, 4...12 ms coil de-energisation and NO opening, 6...17 ms coil de-energisation and NC closing |
| Mechanical durability | 30 Mcycles |
| Maximum operating rate | 180 cyc/mn |
| Inrush power in VA | 70 VA 50 Hz (at 20 °C) |
| Hold-in power consumption in VA | 8 VA 50 Hz (at 20 °C) |
| Minimum switching voltage | 17 V |
| Minimum switching current | 5 mA |
| Non-overlap time | 1.5 ms on energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Mechanical robustness | Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27, Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27, Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6, Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Height | 107 mm |
| Width | 45 mm |
| Depth | 93 mm |
| Net weight | 387 g |
| Standards | EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, JIS C8201-5-1 |
|---|---|
| Product certifications | CB Scheme, CCC, cULus, CE, UKCA, EU-RO-MR by DNV |
| IP degree of protection | IP2X front face conforming to VDE 0106 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -40…60 °C, 60…70 °C with derating |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 0...3000 m |
| Part number | CAD50AM7 |
|---|---|
| Type designation | CAD |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| Warranty (in months) | 18 |
|---|
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5 cm |
| Package 1 Width | 10.5 cm |
| Package 1 Length | 11.5 cm |
| Package 1 Weight | 407 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 15 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 6.42 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 240 |
| Package 3 Height | 75 cm |
| Package 3 Width | 60 cm |
| Package 3 Length | 80 cm |
| Package 3 Weight | 111.22 kg |
| Shipping weight | 0.387 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of CAD is 10 A.
The rated operational voltage of CAD is 220 V AC.
The tariff (HS) code on file for CAD is 853650.
CAD ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.