Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Schneider Electric's CAE40B5 control relay combines 4NO contacts with a 24 V AC coil in the Easy TeSys range, rated 10 A conventional thermal current at up to 690 V. It handles AC-14/AC-15 pilot loads at standard operating rates and connects via screw clamp terminals, suited to DIN rail or screw-fixed panel mounting.
The 4NO contact set gives four make contacts for signal duplication where no break contact is required. This Easy TeSys range is certified CE, CCC, EAC and BIS but carries no UL or CSA listing, so it fits IEC-standard markets; panels that need UL 508 traceability for North America should use the TeSys K (CA2K) or TeSys Deca control relay instead. At 180 cycles/min maximum operating rate it suits standard-duty pilot switching rather than high-cycle automatic sequencing.
| Range | Easy TeSys |
|---|---|
| Range of product | Easy TeSys Control Relay |
| Product or component type | Control relay |
| Device short name | CAE |
| Contactor application | Control circuit |
| Colour | Grey (RAL 7011) |
| Utilisation category | AC-15, AC-14 |
|---|---|
| Pole contact composition | 4 NO |
| [Ue] rated operational voltage | <= 690 V AC |
| Control circuit type | AC at 50 Hz |
| [Uc] control circuit voltage | 24 V AC 50 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| [Ith] conventional free air thermal current | 10 A (at 40 °C) |
| Irms rated making capacity | 140 A at 690 V AC conforming to IEC 60947-5-1 |
| [Icw] rated short-time withstand current | 120 A - 500 ms, 140 A - 100 ms |
| Associated fuse rating | 10 A gG at 690 V conforming to IEC 60947-5-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1 |
| Mounting support | Rail, Plate |
| Connections - terminals | Screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable end, Screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end, Screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end, Screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end, Screw clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable end, Screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end |
| Recommended tightening torque | 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc at 50 Hz, Drop-out: 0.3...0.6 Uc |
| Operating time | 12...22 ms coil energisation and NO closing, 6...17 ms coil de-energisation and NO closing |
| Mechanical durability | 10 Mcycles |
| Maximum operating rate | 180 cyc/mn |
| Inrush power in VA | 70 VA 50 Hz (at 20 °C) |
| Hold-in power consumption in VA | 8 VA 50 Hz (at 20 °C) |
| Minimum switching voltage | 17 V |
| Minimum switching current | 5 mA |
| Insulation resistance | > 10 MOhm |
| Mechanical robustness | Shocks control relay open: 7 Gn for 11 ms, Shocks control relay closed: 10 Gn for 11 ms, Vibrations control relay open: 1.5 Gn, 5...300 Hz, Vibrations control relay closed: 3 Gn, 5...300 Hz |
| Height | 74 mm |
| Width | 45 mm |
| Depth | 80 mm |
| Net weight | 0.28 kg |
| Standards | EN/IEC 60947-1, EN/IEC 60947-5-1, GB/T 14048.1, GB/T 14048.5, IS/IEC 60947-1, IS/IEC 60947-5-1 |
|---|---|
| Product certifications | CB Scheme, CCC, CE, EAC, BIS |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -20…70 °C |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 3000 m without derating |
| Part number | CAE40B5 |
|---|---|
| Type designation | CAE |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| Warranty (in months) | 18 |
|---|
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 7.500 cm |
| Package 1 Length | 8.500 cm |
| Package 1 Weight | 296.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 36 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 10.951 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 576 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 60.000 cm |
| Package 3 Weight | 183.216 kg |
| Shipping weight | 0.28 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
The rated current of CAE is 10 A.
The rated operational voltage of CAE is 24 V AC.
The tariff (HS) code on file for CAE is 853650.
CAE ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.