Part number
CA3KN22BD
Model no
CA3K
88.96 SR On request Dispatch — · From TürkiyeGet a Quote
Schneider TeSys K

Schneider Electric CA3KN22BD TeSys K Control Relay 2NO 2NC 24 V DC Coil Screw Clamp Auxiliary Contactor

TeSys K control relay, 2NO+2NC, 10 A Ith, 24 V DC coil, screw clamp terminals, DIN rail or panel mount.

Rated current
10 A
Rated operational voltage
24 V DC
Poles
3P
EAN
3389110500172
Description

About the CA3K

The Schneider Electric CA3KN22BD is a TeSys K control relay with 2NO+2NC contact composition and a 24 V DC coil, rated 10 A conventional thermal current (Ith) at up to 690 V. It switches AC-15 and DC-13 electromagnetic loads for pilot-circuit control, interlocking and signal duplication, with screw clamp terminals for DIN rail or panel mounting.

Certifications & Standards

  • CE
  • UKCA
  • UL
  • CSA
  • CCC
  • EAC
  • IEC 60947-5-1

Selection Notes

The 2NO+2NC contact composition gives an equal number of make and break signals, useful for interlocking circuits that must mirror a command and its complement. Pick the 24 V DC coil when the control circuit already runs at that voltage; using a coil voltage matching the existing control transformer tap avoids an extra step-down winding. The DC coil has no inrush surge and a longer 30–40 ms closing time than the AC-coil CA2Kseries, which electronic surge suppression trades for lower steady-state power draw — relevant when the relay is driven from a PLC transistor output or a current-limited 24 V DC rail.

Specification

Full specification

56 values · Last verified 30 Oct 2026

Main 10

Range TeSys
Product name TeSys CAK
Product or Component Type Control relay
Device short name CA3K
Contactor application Control circuit
Utilisation category AC-15, DC-13
Pole contact composition 2 NO + 2 NC
[Ue] rated operational voltage <= 690 V <= 400 Hz
Control circuit type DC standard
[Uc] control circuit voltage 24 V DC

Complementary 23

[Ith] conventional free air thermal current 10 A (at 122 °F (50 °C))
Irms rated making capacity 110 A IEC 60947
Associated fuse rating 10 A gG conforming to IEC 60947, 10 A gG conforming to VDE 0660
[Ui] rated insulation voltage 690 V IEC 60947, 750 V VDE 0110 group C, 690 V BS 5424, 600 V CSA C22.2 No 14
Mounting Support Rail, Plate
Connections - terminals screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid, screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid, screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible with cable end, screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end, screw clamp terminals 1 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end, screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible without cable end
Tightening torque 11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm, 11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 0.2 in (6 mm)
Control circuit voltage limits Operational: 0.8...1.15 Uc (at <122 °F (50 °C)), Drop-out: 0.1...0.75 Uc (at <122 °F (50 °C))
Operating time 10 ms coil de-energisation and NO opening, 30...40 ms coil energisation and NO closing, 15 ms coil de-energisation and NC closing, 25...35 ms coil energisation and NC opening
Mechanical durability 20 Mcycles
Maximum operating rate 10000 cyc/h
Immunity to microbreaks 2 ms
Inrush power in W 3 W 68 °F (20 °C))
Hold-in power consumption in W 3 W 68 °F (20 °C)
Heat dissipation 3 W
Minimum switching voltage 17 V
Minimum switching current 5 mA
Non overlap distance 0.02 in (0.5 mm)
Insulation resistance > 10 MOhm
Height 2.3 in (58 mm)
Width 1.8 in (45 mm)
Depth 2.2 in (57 mm)
Net Weight 0.496 lb(US) (0.225 kg)

Environment 9

Standards EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1, CSA C22.2 No 60947-5-1, JIS C8201-5-1
Product Certifications CB Scheme, CCC, UL, CSA, EAC, CE, UKCA
IP degree of protection IP2X
Protective treatment TC IEC 60068
Ambient Air Temperature for Operation -13…122 °F (-25…50 °C)
Ambient Air Temperature for Storage -58…176 °F (-50…80 °C)
Operating altitude 6561.68 ft (2000 m) without derating
Flame retardance V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
Mechanical robustness Vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6, Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, Shocks contactor open10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed15 Gn for 11 ms IEC 60068-2-27
Show all 56 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number CA3KN22BD
Type designation CA3K
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3389110500172

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin ID
Shipping weight 0.225 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for CA3KN22BD

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • UL
  • CSA
  • CE
  • UKCA
  • CCC
  • EAC
  • CB Scheme
  • EN/IEC 60947-5-1
  • GB/T 14048.5
  • UL 60947-5-1
  • CSA C22.2 No 60947-5-1
  • JIS C8201-5-1
Quick answers

Questions about the CA3K

What is the rated current of CA3K?

The rated current of CA3K is 10 A.

Which supply voltage is CA3K rated for?

The rated operational voltage of CA3K is 24 V DC.

What is the HS code of CA3K for customs?

The tariff (HS) code on file for CA3K is 853650.

What is the EAN of CA3K?

The EAN (GTIN) of CA3K is 3389110500172.

Where does CA3K ship from, and how fast?

CA3K ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Schneider Electric Schneider TeSys K

Brand
Schneider Electric
Series
Schneider TeSys K
Series

Other series in Contactors

88.96 SR On request
Get a Quote
Quote

Get a Quote

CA3K

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · CA3KN22BD

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.