Contactors
973 parts 4 sub-families 7 series
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
4 sub-families of Contactors
-
665 parts
Power Contactors (AC-3)
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. AFTeSys Deca3RT2 -
77 parts
Contactor Relays & Auxiliary Contactors
Contactor relays and auxiliary contactors from ABB and Schneider Electric switch control circuits in panels. -
14 parts
Installation Contactors
Installation contactors from ABB switch lighting, heating and other building loads from a distribution board. -
204 parts
Contactor Accessories (Coils, Aux Blocks)
Contactor accessories from ABB and Schneider Electric extend or repair contactors with coils, auxiliary contact blocks and mounting parts.
3RT2944-5AP01 3RT2 Siemens
Siemens · 3RT2 230V Contactor Siemens3RT2946-6A 3RT2 Siemens
Siemens · 3RT2 Contactor Siemens3TY7403-0AB0 3TY7 Siemens
Siemens · 3TY7 24V Contactor Siemens3TY7403-0AF0 3TY7 Siemens
Siemens · 3TY7 110V Contactor Siemens5TT5802-0 5TT5 Siemens
Siemens · 5TT5 20A 230V Contactor Siemens5TT5831-0 5TT5 Siemens
Siemens · 5TT5 25A 230V Contactor Siemens5TT5842-0 5TT5 Siemens
Siemens · 5TT5 40A 230V Contactor Siemens5TT5843-0 5TT5 Siemens
Siemens · 5TT5 40A 230V Contactor Siemens5TT5852-0 5TT5 Siemens
Siemens · 5TT5 63A 230V Contactor SiemensLC1D25E7 LC1D Schneider Electric
Schneider Electric · TeSys Deca 3-Pole 25A 480V AC Coil 15HP Power Contactor Schneider ElectricLAD8N11 Schneider Electric
Schneider Electric · TeSys Deca Side Mount Auxiliary Contact Block Schneider Electric3RT1466-6AP36 3RT1 Siemens
Siemens · 3RT1 400A 3P 690V Contactor Siemens3RT2018-1AP02 3RT2 Siemens
Siemens · 3RT2 16A 3P 400V Contactor Siemens3RT2025-1AP00 3RT2 Siemens
Siemens · 3RT2 17A 3P 400V Contactor Siemens3RT2028-2BB40 3RT2 Siemens
Siemens · 3RT2 38A 3P 400V Contactor Siemens3RT2626-1AP05 3RT2 Siemens
Siemens · 3RT2 29A 3P 400V Contactor Siemens5TT5851-0 5TT5 Siemens
Siemens · 5TT5 63A 230V Contactor Siemens5TT5853-0 5TT5 Siemens
Siemens · 5TT5 63A 230V Contactor Siemens8US1261-5FP08 8US1 Siemens
Siemens · 8US1 56A Contactor SiemensLR9G630 LR9G Schneider Electric
Schneider Electric · TeSys Giga electronic overload relay, 160-630 A, class 5E-30E, ground-fault and phase-imbalance protection. Schneider ElectricLR9G500 LR9G Schneider Electric
Schneider Electric · TeSys Giga electronic overload relay, 125-500 A, class 5E-30E, ground-fault and phase-imbalance protection. Schneider ElectricLP1K1201FD LP1K Schneider Electric
Schneider Electric · TeSys K contactor, 3P, 12 A AC-3, 1NC auxiliary contact, 110 V DC coil. Schneider ElectricLP1K0910FD LP1K Schneider Electric
Schneider Electric · TeSys K contactor, 3P, 9 A AC-3, 1NO auxiliary contact, 110 V DC coil. Schneider ElectricLP1K0901ED LP1K Schneider Electric
Schneider Electric · TeSys K contactor, 3P, 9 A AC-3, 1NC auxiliary contact, 48 V DC coil. Schneider ElectricLP1K0610ED LP1K Schneider Electric
Schneider Electric · TeSys K contactor, 3P, 6 A AC-3, 1NO auxiliary contact, 48 V DC coil. Schneider ElectricLP1K0601ED LP1K Schneider Electric
Schneider Electric · TeSys K contactor, 3P, 6 A AC-3, 1NC auxiliary contact, 48 V DC coil. Schneider ElectricLC1K1610Q7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 16 A AC-3 (7.5 kW at 400 V), 1NO aux, 380-400 V AC 50/60 Hz coil. Schneider ElectricLC1K1601F7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 16 A AC-3 (7.5 kW at 400 V), 1NC aux, 110 V AC 50/60 Hz coil. Schneider ElectricLC1K1210F7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 12 A AC-3 (5.5 kW at 400 V), 1NO aux, 110 V AC 50/60 Hz coil. Schneider ElectricLC1K1210E7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 12 A AC-3 (5.5 kW at 400 V), 1NO aux, 48 V AC 50/60 Hz coil. Schneider ElectricLC1K1201F7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 12 A AC-3 (5.5 kW at 400 V), 1NC aux, 110 V AC 50/60 Hz coil. Schneider ElectricLC1K0910Q7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 9 A AC-3 (4 kW at 400 V), 1NO aux, 380-400 V AC 50/60 Hz coil. Schneider ElectricLC1K0910F7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 9 A AC-3 (4 kW at 400 V), 1NO aux, 110 V AC 50/60 Hz coil. Schneider ElectricLC1K0910E7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 9 A AC-3 (4 kW at 400 V), 1NO aux, 48 V AC 50/60 Hz coil. Schneider ElectricLC1K0901E7 LC1K Schneider Electric
Schneider Electric · TeSys K contactor, 3P 3NO, 9 A AC-3, 48 V AC AC coil, 1NC aux. Schneider ElectricLC1K0610Q7 LC1K Schneider Electric
Schneider Electric · TeSys K contactor, 3P 3NO, 6 A AC-3, 380-400 V AC AC coil, 1NO aux. Schneider ElectricLC1K0610F7 LC1K Schneider Electric
Schneider Electric · TeSys K contactor, 3P 3NO, 6 A AC-3, 110 V AC AC coil, 1NO aux. Schneider ElectricLC1K0610E7 LC1K Schneider Electric
Schneider Electric · TeSys K contactor, 3P 3NO, 6 A AC-3, 48 V AC AC coil, 1NO aux. Schneider ElectricLC1K0601F7 LC1K Schneider Electric
Schneider Electric · TeSys K contactor, 3P 3NO, 6 A AC-3, 110 V AC AC coil, 1NC aux. Schneider ElectricLC1K0601E7 LC1K Schneider Electric
Schneider Electric · TeSys K contactor, 3P 3NO, 6 A AC-3, 48 V AC AC coil, 1NC aux. Schneider ElectricLA2KT2U Schneider Electric
Schneider Electric · Schneider Electric LA2KT2U TeSys K time delay auxiliary contact block, 1 C/O, on-delay 1-30 s, 110-240 V AC coil. Schneider ElectricLA2KT2E Schneider Electric
Schneider Electric · Schneider Electric LA2KT2E TeSys K time delay auxiliary contact block, 1 C/O, on-delay 1-30 s, 24-48 V AC/DC coil. Schneider ElectricLZ8H6X5BD LZ8H Schneider Electric
Schneider Electric · TeSys Hybrid ultra-compact reversing starter with Safe Torque Off, 1.5-9 A, 3 kW, 24 V DC coil. Schneider ElectricLZ8H2X4BD LZ8H Schneider Electric
Schneider Electric · TeSys Hybrid ultra-compact reversing starter with Safe Torque Off, 0.18-2.4 A, 0.75 kW, 24 V DC coil. Schneider ElectricLZ7H2X4BD LZ7H Schneider Electric
Schneider Electric · TeSys Hybrid ultra-compact starter with Safe Torque Off, 0.18-2.4 A, 0.75 kW at 400 V, 24 V DC coil. Schneider ElectricLZ2H6X5BD LZ2H Schneider Electric
Schneider Electric · TeSys Hybrid ultra-compact reversing starter, 1.5-9 A, 3 kW at 400 V, 24 V DC coil. Schneider ElectricLZ2H2X4FU LZ2H Schneider Electric
Schneider Electric · TeSys Hybrid ultra-compact reversing starter, 0.18-2.4 A, 0.75 kW at 400 V, 110-230 V AC coil. Schneider ElectricCan't find the part you need?
Send the part numbers or the specs you need. We reply with price, stock and dispatch time per line.
Contactors buying guide
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
Contactors questions
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.