Part number
LC1K0610E7
Model no
LC1K
65.60 SR On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric LC1K0610E7 TeSys K Contactor 3P 3NO AC-3 6 A 1NO Aux 48 V AC Coil Contactor

TeSys K contactor, 3P 3NO, 6 A AC-3, 48 V AC AC coil, 1NO aux.

Rated current
6 A
Rated operational voltage
48 V AC
Motor power
2.2 kW
Poles
3P
EAN
3389110374742
Description

About the LC1K

The Schneider Electric LC1K0610E7 is a compact 3-pole TeSys K contactor rated 6 A AC-3, switching motors up to 2.2 kW at 400 V. It carries a 48 V AC AC coil and a built-in 1NO auxiliary contact, in a 45 mm-wide DIN-rail housing sized for simple motor-control and machine-building panels.

Certifications & Standards

  • CE
  • UKCA
  • UL
  • CSA
  • CCC
  • EN/IEC 60947-4-1

Selection Notes

Where the LC1K0601E7's 1 NC contact is wired for interlocking, the LC1K0610E7's 1 NO contact closes on pickup — the configuration needed for running-indication lamps, a sealing-in (hold) circuit, or feeding a PLC input that confirms the contactor has actually closed. Current rating and coil voltage are unchanged from the 1 NC version: 6 A AC-3 (2.2 kW at 400 V) on a 48 V AC coil.

Specification

Full specification

68 values · Last verified 29 Oct 2026

Main 5

Range TeSys
Product or Component Type Contactor
Device short name LC1K
Device Application Control
Contactor application Motor control

Complementary 42

Utilisation category AC-3 AC-3e AC-4
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit <= 690 V AC <= 400 Hz Signalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
Control circuit type AC 50/60 Hz
[Uc] control circuit voltage 48 V AC 50/60 Hz
Motor power kW 1.5 kW 220...230 V AC 50/60 Hz AC-3 2.2 kW 380...415 V AC 50/60 Hz AC-3 3 kW 440/690 V AC 50/60 Hz AC-3 1.5 kW 220...230 V AC 50/60 Hz AC-3e 2.2 kW 380...415 V AC 50/60 Hz AC-3e 3 kW 440/690 V AC 50/60 Hz AC-3e 1.5 kW 220...230 V AC 50/60 Hz AC-4 2.2 kW 380...415 V AC 50/60 Hz AC-4 3 kW 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition 1 NO
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 140 °F (60 °C)) for power circuit 10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current 90 A 122 °F (50 °C) - 1 s for power circuit 85 A 122 °F (50 °C) - 5 s for power circuit 80 A 122 °F (50 °C) - 10 s for power circuit 60 A 122 °F (50 °C) - 30 s for power circuit 45 A 122 °F (50 °C) - 1 min for power circuit 40 A 122 °F (50 °C) - 3 min for power circuit 20 A 122 °F (50 °C) - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14
Insulation resistance > 10 MOhm for signalling circuit
Inrush power in VA 30 VA (at 68 °F (20 °C))
Hold-in power consumption in VA 4.5 VA (at 68 °F (20 °C))
Heat dissipation 1.3 W
Control circuit voltage limits Operational: 0.8...1.15 Uc (at = 0.20 Uc (at <122 °F (50 °C))
Connections - terminals Screw clamp terminals 1 0.002...0.006 in2 (1.5...4 mm2)solid screw clamp terminals 1 0.001...0.006 in2 (0.75...4 mm2)flexible without cable end screw clamp terminals 1 0.0005...0.004 in2 (0.34...2.5 mm2)flexible with cable end screw clamp terminals 2 0.002...0.006 in2 (1.5...4 mm2)solid screw clamp terminals 2 0.001...0.006 in2 (0.75...4 mm2)flexible without cable end screw clamp terminals 2 0.0005...0.002 in2 (0.34...1.5 mm2)flexible with cable end
Maximum operating rate 3600 cyc/h
Coil technology Without built-in suppressor module
Auxiliary contacts type Instantaneous 1 NO
Signalling circuit frequency <= 400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Mounting Support Rail Plate
Tightening torque 7.08...11.5 lbf.in (0.8...1.3 N.m) screw clamp terminals Philips No 2 7.08...11.5 lbf.in (0.8...1.3 N.m) screw clamp terminals flat Ø 6 mm 7.08...11.5 lbf.in (0.8...1.3 N.m) screw clamp terminals pozidriv No 2
Operating time 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Non overlap distance 0.02 in (0.5 mm)
Mechanical durability 10 Mcycles
Electrical durability 1.3 Mcycles 6 A AC-3 <= 440 V 1.3 Mcycles 6 A AC-3e <= 440 V 0.05 Mcycles 36 A AC-4 <= 440 V
Mechanical robustness Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Height 2.3 in (58 mm)
Width 1.8 in (45 mm)
Depth 2.2 in (57 mm)
Net Weight 0.40 lb(US) (0.18 kg)

Environment 7

Standards EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ
Product Certifications CB Scheme CCC UL CSA EAC CE UKCA
IP degree of protection IP2X VDE 0106
Protective treatment TC IEC 60068 TC DIN 50016
Ambient Air Temperature for Storage -58...176 °F (-50...80 °C)
Operating altitude 6561.68 ft (2000 m) without derating
Flame retardance V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
Show all 68 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number LC1K0610E7
Type designation LC1K
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3389110374742

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin ID
Shipping weight 0.18 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 29 Oct 2026

Documents

Documents for LC1K0610E7

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • UL
  • CSA
  • CE
  • UKCA
  • CCC
  • EAC
  • CB Scheme
Quick answers

Questions about the LC1K

What is the rated current of LC1K?

The rated current of LC1K is 6 A.

Which supply voltage is LC1K rated for?

The rated operational voltage of LC1K is 48 V AC.

What motor power is LC1K rated for?

The rated motor power of LC1K is 2.2 kW.

What is the HS code of LC1K for customs?

The tariff (HS) code on file for LC1K is 85365080.

What is the EAN of LC1K?

The EAN (GTIN) of LC1K is 3389110374742.

Where does LC1K ship from, and how fast?

LC1K ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Schneider Electric Schneider TeSys K

Brand
Schneider Electric
Series
Schneider TeSys K
Series page →
Series

Other series in Contactors

65.60 SR On request
Get a Quote
Quote

Get a Quote

LC1K

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LC1K0610E7

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart