VFD for Compressors: Selection Guide
How to select and size a VFD for screw, reciprocating and centrifugal compressors, covering overload rating, turndown limits and energy savings.
The Siemens 6SL3210-1PH22-3UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 15.00 kW at high overload and 18.50 kW at low overload in the FSD frame. The module integrates a braking chopper, has no input filter, and ships without a control unit or operator panel; it runs from CU firmware V4.7 HF8. It weighs 17.4 kg with IP20 protection in the 472 x 200 x 237 mm FSD frame.
This is the top of the mid-range FSD lineup in this batch before stepping up to the FSE frame at 37.00 kW low-overload; pick it over the 11.00 kW / 15.00 kW module when the driven load's continuous current draw is closer to 23.00 A than to 19.00 A. Max. output current of 38.00 A gives headroom for the 200% / 3 s overload window on high-overload duty, which matters for machines with high breakaway torque, such as positive-displacement pumps. Since the module ships unfiltered, plan for an external EMC filter if conducted-emission limits apply to the installation.
| Input: Number of phases | 3 AC |
|---|---|
| Input: Line voltage | 500 ... 690 V ±10 % |
| Input: Line frequency | 47 ... 63 Hz |
| Input: Rated current (LO) | 22.00 A |
| Input: Rated current (HO) | 20.00 A |
| Output: Number of phases | 3 AC |
| Output: Rated voltage | 1) |
| Output: Rated power (LO) | 18.50 kW / 20.00 hp |
| Output: Rated power (HO) | 15.00 kW / 15.00 hp |
| Output: Rated current (LO) | 23.00 A |
| Output: Rated current (HO) | 19.00 A |
| Output: Max. output current | 38.00 A |
| Output: Pulse frequency | 2 kHz |
| Output: Output frequency for vector control | 0 ... 200 Hz |
| Output: Output frequency for V/f control | 0 ... 550 Hz |
| Low Overload (LO) | 1.1 x rated output current (i.e. 110 % overload) for 57 s with a cycle time of |
| High Overload (HO) | 1.5 × output current rating (i.e., 150 % overload) for 57 s with a cycle time of |
| Power factor λ | 0.90 |
|---|---|
| Offset factor cos φ | 0.99 |
| Efficiency η | 0.98 |
| Sound pressure level (1m) | 72 dB |
| Power loss | 0.48 kW |
| Filter class (integrated) | - |
| Cooling | Internal air cooling |
|---|---|
| Cooling air requirement | 0.055 m³/s (1.942 ft³/s) |
| Installation altitude | 1,000 m (3,280.84 ft) |
| Ambient temperature: Operation LO | -20 ... 40 °C (-4 ... 104 °F) |
| Ambient temperature: Operation HO | -20 ... 50 °C (-4 ... 122 °F) |
| Ambient temperature: Transport | -25 ... 55 °C (-13 ... 131 °F) |
| Ambient temperature: Storage | -25 ... 55 °C (-13 ... 131 °F) |
| Relative humidity: Max. operation | 95 % RH, condensation not permitted |
| Part number | 6SL3210-1PH22-3UL0 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 4042948668283 |
| Line side: Version | screw-type terminal |
|---|---|
| Motor end: Version | Screw-type terminals |
| Max. motor cable length: Shielded | 200 m (656.17 ft) |
| Max. motor cable length: Unshielded | 300 m (984.25 ft) |
| Degree of protection | IP20 / UL open type |
|---|---|
| Frame size | FSD |
| Dimensions: Width | 200 mm (7.87 in) |
| Dimensions: Height | 472 mm (18.58 in) |
| Dimensions: Depth | 237 mm (9.33 in) |
| Compliance with standards | UL, cUL, CE, C-Tick (RCM), SEMI F47 |
|---|---|
| CE marking | Low-voltage directive 2006/95/EC |
| Page 1 of 1 | Generated Sun Nov 1 01:03:03 CET 2026 |
| Net weight | 17 kg |
|---|---|
| Shipping weight | 19.4 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of 6SL3210-1PH22-3UL0 is 23.00 A.
The rated operational voltage of 6SL3210-1PH22-3UL0 is 500–690 V AC.
The rated motor power of 6SL3210-1PH22-3UL0 is 18.50 (LO) – 15.00 (HO) kW.
The tariff (HS) code on file for 6SL3210-1PH22-3UL0 is 85044095.
The EAN (GTIN) of 6SL3210-1PH22-3UL0 is 4042948668283.
6SL3210-1PH22-3UL0 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
How to select and size a VFD for screw, reciprocating and centrifugal compressors, covering overload rating, turndown limits and energy savings.
Size your VFD correctly with our complete guide covering FLA calculation, duty cycle, derating, harmonics, and brand-specific sizing tables. Shop at Stoklink.
Compare VFD types including VSI, CSI, PWM, and matrix converters with selection criteria, harmonic data, and real installation examples. Shop at Stoklink.