SIMATIC S7-400

Siemens 6ES7414-5HM06-0AB0 SIMATIC S7-400H CPU 414-5H PN/DP 4MB Fault-Tolerant PLC

SIMATIC S7-400H fault-tolerant CPU 414-5H PN/DP, 4MB work memory, 5 interfaces, 2 rack slots.

Communication
MPI/DP, DP, PROFINET, 2x sync module
EAN
4019169234719
Description

About the CPU 414-5H PN/DP

The Siemens CPU 414-5H PN/DP (6ES7414-5HM06-0AB0) is a fault-tolerant central processing unit for SIMATIC S7-400H and S7-400F/FH systems, with 4 MB of work memory split 2 MB program and 2 MB data. Five interfaces cover MPI/DP, a dedicated DP port, PROFINET, and two synchronization module ports for redundant CPU pairing.

Selection Notes

Against the 412-5H, this CPU quadruples work memory to 4 MB and doubles the connectable-OP count to 63, while keeping the same five-interface layout, MPI/DP, DP, PROFINET, and two synchronization ports for redundant pairing. Pick it when a fault-tolerant S7-400H station, or a safety program on S7-400F/FH, needs more than the 412-5H's 1 MB and 47-OP ceiling. Processing time also drops to 18.75 ns typical from 31.25 ns, cutting scan time on identical logic.

Specification

Full specification

349 values · Last verified 01 Nov 2026

General information 5

Product type designation CPU 414-5H PN/DP
HW functional status 1
Firmware version V6.0
Product function: Isochronous mode No
Engineering with: Programming package As of STEP 7 V5.5 SP2 with HF1

CiR - Configuration in RUN 2

CiR synchronization time, basic load 100 ms
CiR synchronization time, time per I/O byte 0 µs

Supply voltage 1

Rated value (DC) Power supply via system power supply
Show all 349 specifications ↓ Show less ↑341 more values in Identification, Input current, Power loss, Storage, Battery, CPU processing times, CPU-blocks, Counters, timers and their retentivity, Data areas and their retentivity, Address area, Hardware configuration, Time of day, Interfaces, 1. Interface, 2. Interface, 3. Interface, 4. Interface, 5. Interface, Protocols, Isochronous mode, Communication functions, S7 message functions, Test commissioning functions, EMC, Configuration, Dimensions, Weights, General Product Approval For use in hazardous locations, Logistics.

Identification 10

Part number 6ES7414-5HM06-0AB0
Type designation CPU 414-5H PN/DP
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Phase-out announced by the manufacturer
EAN 4019169234719
ETIM class EC000236
eCl@ss 27242207

Input current 4

from backplane bus 5 V DC, typ. 1.6 A
from backplane bus 5 V DC, max. 1.9 A
from backplane bus 24 V DC, max. 150 mA; 150 mA per DP interface
from interface 5 V DC, max. 90 mA; At each DP interface

Power loss 1

Power loss, typ. 7.5 W

Storage 13

Type of memory other
Work memory: integrated 4 Mbyte
Work memory: integrated (for program) 2 Mbyte
Work memory: integrated (for data) 2 Mbyte
Work memory: expandable No
Load memory: expandable FEPROM Yes; with Memory Card (FLASH)
Load memory: expandable FEPROM, max. 64 Mbyte
Load memory: integrated RAM, max. 512 kbyte
Load memory: expandable RAM Yes
Load memory: expandable RAM, max. 64 Mbyte
Backup: present Yes
Backup: with battery Yes; all data
Backup: without battery No

Battery 4

Backup battery: Backup current, typ. 180 µA; Valid up to 40°C
Backup battery: Backup current, max. 1 000 µA
Backup battery: Backup time, max. Dealt with in the module data manual with the secondary conditions and the factors of influence
Backup battery: Feeding of external backup voltage to CPU 5 V DC to 15 V DC

CPU processing times 4

for bit operations, typ. 18.75 ns
for word operations, typ. 18.75 ns
for fixed point arithmetic, typ. 18.75 ns
for floating point arithmetic, typ. 37.5 ns

CPU-blocks 19

DB: Number, max. 6 000; Number range: 1 to 16000
DB: Size, max. 64 kbyte
FB: Number, max. 3 000; Number range: 0 to 7999
FB: Size, max. 64 kbyte
FC: Number, max. 3 000; Number range: 0 to 7999
FC: Size, max. 64 kbyte
OB: Number, max. see instruction list
OB: Size, max. 64 kbyte
OB: Number of free cycle OBs 1; OB 1
OB: Number of time alarm OBs 4; OB 10-13
OB: Number of delay alarm OBs 4; OB 20-23
OB: Number of cyclic interrupt OBs 4; OB 32-35
OB: Number of process alarm OBs 4; OB 40-43
OB: Number of DPV1 alarm OBs 3; OB 55-57
OB: Number of startup OBs 2; OB 100, 102
OB: Number of asynchronous error OBs 9; OB 80-88
OB: Number of synchronous error OBs 2; OB 121, 122
Nesting depth: per priority class 24
Nesting depth: additional within an error OB 1

Counters, timers and their retentivity 16

S7 counter: Number Retentivity 2 048
S7 counter: adjustable Yes
S7 counter: preset Counting range Z 0 to Z 7
S7 counter: lower limit 0
S7 counter: upper limit 999
IEC counter: present Yes
IEC counter: Type SFB
IEC counter: Number Unlimited (limited only by RAM capacity)
S7 timer: Number Retentivity 2 048
S7 timer: adjustable Yes
S7 timer: preset Time range No times retentive
S7 timer: lower limit 10 ms
S7 timer: upper limit 9 990 s
IEC timer: present Yes
IEC timer: Type SFB
IEC timer: Number Unlimited (limited only by RAM capacity)

Data areas and their retentivity 7

Retentive data area (incl. timers, counters, flags), max. Total working and load memory (with backup battery)
Flag: Size, max. 8 192 byte
Flag: Retentivity available Yes
Flag: Retentivity preset MB 0 to MB 15
Flag: Number of clock memories 8; in 1 memory byte
Local data: adjustable, max. 16 kbyte
Local data: preset 8 kbyte

Address area 15

I/O address area: Inputs 8 kbyte
I/O address area: Outputs 8 kbyte
Process image: Inputs, adjustable 8 kbyte
Process image: Outputs, adjustable 8 kbyte
Process image: Inputs, default 256 byte
Process image: Outputs, default 256 byte
Process image: consistent data, max. 244 byte
Process image: Access to consistent data in process image Yes
Subprocess images: Number of subprocess images, max. 15
Digital channels: Inputs 65 536
Digital channels: of which central 65 536
Digital channels: Outputs 65 536
Analog channels: Inputs 4 096
Analog channels: of which central 4 096
Analog channels: Outputs 4 096

Hardware configuration 16

Number of expansion units, max. 21
connectable OPs 63
Multicomputing No
Interface modules: Number of connectable IMs (total), max. 6
Interface modules: Number of connectable IM 460s, max. 6
Interface modules: Number of connectable IM 463s, max. 4; Single mode only
Number of DP masters: integrated 2
Number of DP masters: via CP 10; CP 443-5 Extended
Number of DP masters: Mixed mode IM + CP permitted No
Number of DP masters: via interface module 0
Number of IO Controllers: Integrated 1
Number of IO Controllers: Via CP 0
Number of operable FMs and CPs (recommended): FM See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections
Number of operable FMs and CPs (recommended): CP, PtP See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections
Number of operable FMs and CPs (recommended): PROFIBUS and Ethernet CPs 14; Of which max. 10 CP as DP master
Slots: required slots 2

Time of day 20

Clock: Hardware clock (real-time) Yes
Clock: retentive and synchronizable Yes
Clock: Resolution 1 ms
Clock: Deviation per day (buffered), max. 1.7 s; Power off
Clock: Deviation per day (unbuffered), max. 8.6 s; Power on
Operating hours counter: Number 16
Operating hours counter: Number/Number range 0 to 15
Operating hours counter: Range of values SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
Operating hours counter: Granularity 1 h
Operating hours counter: retentive Yes
Clock synchronization: supported Yes
Clock synchronization: to MPI, master Yes
Clock synchronization: on MPI, device Yes
Clock synchronization: to DP, master Yes
Clock synchronization: on DP, device Yes
Clock synchronization: in AS, master Yes
Clock synchronization: in AS, device Yes
Clock synchronization: on Ethernet via NTP Yes; As client
Time difference in system when synchronizing via: Ethernet, max. 10 ms; Via NTP
Time difference in system when synchronizing via: MPI, max. 200 ms

Interfaces 3

Number of RS 485 interfaces 2
Number of other interfaces 2; Fiber-optic interface
Optical interface No

1. Interface 39

Interface type MPI/PROFIBUS DP
Isolated Yes
Interface types: RS 485 Yes
Interface types: Output current of the interface, max. 150 mA
Protocols: MPI Yes
Protocols: PROFIBUS DP master Yes
Protocols: PROFIBUS DP device No
MPI: Number of connections 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
MPI: Transmission rate, max. Services 12 Mbit/s
MPI: PG/OP communication Yes
MPI: Routing Yes
MPI: Global data communication No
MPI: S7 basic communication No
MPI: S7 communication Yes
MPI: S7 communication, as client Yes
MPI: S7 communication, as server Yes
PROFIBUS DP master: Number of connections, max. 16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
PROFIBUS DP master: Transmission rate, max. 12 Mbit/s
PROFIBUS DP master: max. number of DP devices Services 32
PROFIBUS DP master: PG/OP communication Yes
PROFIBUS DP master: Routing Yes
PROFIBUS DP master: Global data communication No
PROFIBUS DP master: S7 basic communication No
PROFIBUS DP master: S7 communication Yes
PROFIBUS DP master: S7 communication, as client Yes
PROFIBUS DP master: S7 communication, as server Yes
PROFIBUS DP master: Equidistance No
PROFIBUS DP master: Isochronous mode No
PROFIBUS DP master: SYNC/FREEZE No
PROFIBUS DP master: activation/deactivation of DP devices No
PROFIBUS DP master: Direct data exchange (slave-to-slave communication) No
PROFIBUS DP master: DPV1 Address area Yes
PROFIBUS DP master: Inputs, max. 2 kbyte
PROFIBUS DP master: Outputs, max. User data per DP device 2 kbyte
PROFIBUS DP master: user data per DP device, max. 244 byte
PROFIBUS DP master: Outputs, max. 244 byte
PROFIBUS DP master: Slots, max. 244
PROFIBUS DP master: per slot, max. 128 byte
PROFIBUS DP device: Number of connections No configuration of CPU as DP slave

2. Interface 38

Interface type PROFINET
Isolated Yes
automatic detection of transmission rate Yes; Autosensing
Autonegotiation Yes
Autocrossing Yes
Change of IP address at runtime, supported No
Interface types: RJ 45 (Ethernet) Yes
Interface types: Number of ports 2
Interface types: integrated switch Yes
Protocols: PROFINET IO Controller Yes
Protocols: PROFINET IO Device No
Protocols: PROFINET CBA No
Protocols: PROFIBUS DP master No
Protocols: PROFIBUS DP device No
Protocols: Open IE communication Yes
Protocols: Web server No
Protocols: Point-to-point connection No
Protocols: Media redundancy Yes
PROFINET IO Controller: Transmission rate, max. Services 100 Mbit/s
PROFINET IO Controller: PG/OP communication Yes
PROFINET IO Controller: S7 communication Yes
PROFINET IO Controller: Isochronous mode No
PROFINET IO Controller: Shared device Yes; Single mode only
PROFINET IO Controller: Prioritized startup No
PROFINET IO Controller: Number of connectable IO Devices, max. 256; In redundant mode via both interfaces
PROFINET IO Controller: Number of connectable IO Devices for RT, max. 256
PROFINET IO Controller: of which in line, max. 256
PROFINET IO Controller: Activation/deactivation of IO Devices No
PROFINET IO Controller: IO Devices changing during operation (partner ports), supported No
PROFINET IO Controller: Device replacement without swap medium Yes
PROFINET IO Controller: Send cycles 250 µs, 500 µs, 1 ms, 2 ms, 4 ms
PROFINET IO Controller: Updating time Address area 250 µs to 512 ms, minimum value depends on the number of configured user data and the configured single or redundant mode
PROFINET IO Controller: Inputs, max. 8 kbyte
PROFINET IO Controller: Outputs, max. 8 kbyte
PROFINET IO Controller: User data consistency, max. 1 024 byte
Open IE communication: Number of connections, max. 62
Open IE communication: Local port numbers used at the system end 0, 20, 21, 25, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535
Open IE communication: Keep-alive function, supported Yes

3. Interface 28

Interface type PROFIBUS DP
Interface types: RS 485 Yes
Interface types: Output current of the interface, max. 150 mA
Protocols: PROFIBUS DP master Yes
Protocols: PROFIBUS DP device No
PROFIBUS DP master: Number of connections, max. 16
PROFIBUS DP master: Transmission rate, max. 12 Mbit/s
PROFIBUS DP master: max. number of DP devices Services 96
PROFIBUS DP master: PG/OP communication Yes
PROFIBUS DP master: Routing Yes
PROFIBUS DP master: Global data communication No
PROFIBUS DP master: S7 basic communication No
PROFIBUS DP master: S7 communication Yes
PROFIBUS DP master: S7 communication, as client Yes
PROFIBUS DP master: S7 communication, as server Yes
PROFIBUS DP master: Equidistance No
PROFIBUS DP master: Isochronous mode No
PROFIBUS DP master: SYNC/FREEZE No
PROFIBUS DP master: activation/deactivation of DP devices No
PROFIBUS DP master: Direct data exchange (slave-to-slave communication) No
PROFIBUS DP master: DPV0 Yes
PROFIBUS DP master: DPV1 Address area Yes
PROFIBUS DP master: Inputs, max. 6 kbyte
PROFIBUS DP master: Outputs, max. User data per DP device 6 kbyte
PROFIBUS DP master: user data per DP device, max. 244 byte
PROFIBUS DP master: Outputs, max. 244 byte
PROFIBUS DP master: Slots, max. 244
PROFIBUS DP master: per slot, max. 128 byte

4. Interface 2

Interface type Pluggable synchronization submodule (FO)
Plug-in interface modules Synchronization modules 6ES7960-1AA06-0XA0 or 6ES7960-1AB06-0XA0

5. Interface 2

Interface type Pluggable synchronization submodule (FO)
Plug-in interface modules Synchronization modules 6ES7960-1AA06-0XA0 or 6ES7960-1AB06-0XA0

Protocols 10

Redundancy mode Media redundancy: Switchover time on line break, typ. 200 ms
Redundancy mode Media redundancy: Number of stations in the ring, max. 50
SIMATIC communication: S7 routing Yes
Open IE communication: TCP/IP Yes; via integrated PROFINET interface and loadable FBs
Open IE communication: Number of connections, max. 62
Open IE communication: Data length, max. 32 kbyte
Open IE communication: several passive connections per port, supported Yes
Open IE communication: ISO-on-TCP (RFC1006) Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs
Open IE communication: UDP Yes; via integrated PROFINET interface and loadable FBs
Web server: supported No

Isochronous mode 1

Equidistance No

Communication functions 27

PG/OP communication Yes
Number of connectable OPs with message processing 63; When using Alarm_S/SQ and Alarm_D/DQ
Number of connectable OPs without message processing 63
Data record routing Yes
Global data communication: supported No
S7 basic communication: supported No
S7 communication: supported Yes
S7 communication: as server Yes
S7 communication: as client Yes
S7 communication: User data per job, max. 64 kbyte
S7 communication: User data per job (of which consistent), max. 462 byte; 1 variable
S5 compatible communication: supported Yes; (via CP max. 10 and FC AG_SEND and FC AG_RECV)
S5 compatible communication: User data per job, max. 8 kbyte
S5 compatible communication: User data per job (of which consistent), max. 240 byte
S5 compatible communication: Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. 64/64
Standard communication (FMS): supported Yes; Via CP and loadable FB
Number of connections: overall 64
usable for PG communication: reserved for PG communication 1
usable for PG communication: adjustable for PG communication, max. 0
usable for OP communication: reserved for OP communication 1
usable for OP communication: adjustable for OP communication, max. 0
usable for S7 basic communication: reserved for S7 basic communication 0
usable for S7 basic communication: adjustable for S7 basic communication, max. 0
usable for S7 communication: reserved for S7 communication 0
usable for S7 communication: adjustable for S7 communication, max. 0
usable for routing: reserved for routing 0
usable for routing: adjustable for routing, max. 0

S7 message functions 11

Number of login stations for message functions, max. 63; Max. 63 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
Symbol-related messages No
SCAN procedure No
Program alarms Yes
Process diagnostic messages Yes
simultaneously active Alarm_S blocks, max. 400; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
Alarm 8-blocks Yes
Number of instances for alarm 8 and S7 communication blocks, max. 2 500
preset, max. 900
Process control messages Yes
Number of archives that can log on simultaneously (SFB 37 16

Test commissioning functions 14

Status block Yes
Single step Yes
Number of breakpoints 16
Status/control: Status/control variable Yes; Up to 16 variable tables
Status/control: Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Status/control: Number of variables, max. 70
Forcing: Forcing Yes
Forcing: Forcing, variables Inputs/outputs, bit memories, distributed I/Os
Forcing: Number of variables, max. 256
Diagnostic buffer: present Yes
Diagnostic buffer: Number of entries, max. 3 200
Diagnostic buffer: can be set Yes
Diagnostic buffer: preset 120
Service data: Can be read out Yes

EMC 1

Emission of radio interference acc. to EN 55 011: Limit class A, for use in industrial areas Yes

Configuration 25

Configuration software: STEP 7 Yes
Programming: Command set see instruction list
Programming: Nesting levels 7
Programming: Access to consistent data in process image Yes
Programming: System functions (SFC) see instruction list
Programming: System function blocks (SFB) Programming language see instruction list
Programming: LAD Yes
Programming: FBD Yes
Programming: STL Yes
Programming: SCL Yes
Programming: CFC Yes
Programming: GRAPH Yes
Programming: HiGraph® Number of simultaneously active SFCs Yes
Programming: RD_REC 8
Programming: WR_REC 8
Programming: WR_PARM 8
Programming: PARM_MOD 1
Programming: WR_DPARM 2
Programming: DPNRM_DG 8
Programming: RDSYSST 8
Programming: DP_TOPOL Number of simultaneously active SFBs 1
Programming: RDREC 8
Programming: WRREC 8
Know-how protection: User program protection/password protection Yes
Know-how protection: Block encryption Yes; With S7 block Privacy

Dimensions 3

Width 50 mm
Height 290 mm
Depth 219 mm

Weights 1

Weight, approx. 995 g

General Product Approval For use in hazardous locations 1

China RoHS Miscellaneous Manufacturer Declara- tion

Logistics 6

Net weight 1.32 kg
Country of origin DE
Shipping weight 1.82 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 01 Nov 2026

Documents

Documents for 6ES7414-5HM06-0AB0

No documents are on file for this part yet.

Ask us for the datasheet
Quick answers

Questions about the CPU 414-5H PN/DP

What is the HS code of CPU 414-5H PN/DP for customs?

The tariff (HS) code on file for CPU 414-5H PN/DP is 85371091.

What is the EAN of CPU 414-5H PN/DP?

The EAN (GTIN) of CPU 414-5H PN/DP is 4019169234719.

Where does CPU 414-5H PN/DP ship from, and how fast?

CPU 414-5H PN/DP ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

Series

Siemens SIMATIC S7-400

Brand
Siemens
Series
SIMATIC S7-400
43,420.85 SR On request
Get a Quote
Quote

Get a Quote

CPU 414-5H PN/DP

Genuine parts

Genuine, factory-sealed parts

Siemens · 6ES7414-5HM06-0AB0

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart