- Part number
- 5SD7464-1
Siemens has discontinued 5SD7464-1
We sell remaining stock while it lasts.
No replacement announced yet. Tell us the application and we will propose an alternative.
Description
About the 5SD7464-1
About the 5SD7464-1
The Siemens 5SD7464-1 is a surge protection device from the SENTRON/SIRIUS 5SD7 series. Surge arrester type, 2, requirement class C, Uc 350 V, protective modules, plug-in, 4-pole, 3+1 circuit for TN-S and TT systems, with remote display. Supplied by Stoklink for industrial and commercial low-voltage applications.
Certifications & Standards
- IEC 61643-11
- EN 61643-11
Applications & Use Cases
The Siemens 5SD7464-1 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 5SD7 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.
Specification
Full specification
General data 17
| standard | IEC 61643-11: 2011, EN 61643-11: 2012 |
|---|---|
| product designation | Surge protection device |
| SPD classification according to EN 61643-11: Test Class I, Type 1 | No |
| SPD classification according to EN 61643-11: Test Class II, Type 2 | Yes |
| SPD classification according to EN 61643-11: Test Class III, Type 3 | No |
| number of SPD ports | 1 |
| design of the product | Surge arrester |
| design of pole | 3+N/PE |
| designation of the protective paths | L-N, L-PE, N-PE |
| accessories | 3 x 5SD7468-1 + 1 x 5SD7488-0 |
| fastening method | TH35 DIN rail |
| size of surge arrester | 4 MW |
| overvoltage category according to IEC 61010-1 | III |
| protection class IP at connection all terminals | IP20 |
| relative humidity during operation | 5 ... 95 % |
| width | 71.5 mm |
| depth | 71.5 mm |
Electrical data 15
| type of distribution system | TN-S, TT |
|---|---|
| operating voltage: at AC | 230 V |
| value range of the operating frequency | 50 / 60 Hz |
| continuous operating voltage: at AC maximum | 350 V |
| discharge current at (8/20) µs | 20 kA |
| discharge current 1 phase at (8/20) µs maximum | 40 kA |
| follow current extinguishing capability: between N and PE | 100 A (260 V) |
| short-circuit rating (SCCR) at 264 V | 25 kA |
| protection level: between N and L | 1.4 kV |
| protection level: between PE and N and/or L | 1.5 kV |
| response value of the surge voltage at 6 kV at (1.2/50) µs: between N and PE | 1.5 kV |
| response value of the surge voltage at 6 kV at (1.2/50) µs: response time between L and (PE)N | 25 ns |
| adjustable response factor of tripping current | 1.6 |
| fuse protection type at V-shaped connection | 80 A AC (gG) |
| fuse protection type for T-connector | 125 A AC (gG) |
Connections/ Terminals 9
| type of electrical connection | Screw terminal |
|---|---|
| stripped length | 16 mm |
| tightening torque | 4.3 ... 4.7 N·m |
| connectable conductor cross-section: for finely stranded conductor | 1.5 ... 25 mm2 |
| connectable conductor cross-section: for rigid conductor | 1.5 ... 35 mm2 |
| connectable conductor cross-section: finely stranded | 0.5 ... 25 mm2 |
| AWG number as coded connectable conductor cross section | 15 ... 2 |
| design of the thread of the connection screw | M5 |
| signal design | Optical, remote signaling contact |
Show all 67 specifications ↓ Show less ↑26 more values in Identification, Indicator/remote signaling, NEMA/UL - Data, Logistics.
Identification 9
| Part number | 5SD7464-1 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Discontinued by the manufacturer |
| EAN | 4001869340630 |
| ETIM class | EC000941 |
| eCl@ss | 27179090 |
Indicator/remote signaling 8
| product component remote signaling contact | Yes |
|---|---|
| operating voltage of the remote signaling contacts at AC | 5 V |
| operational current of the remote signaling contacts at AC | 5 mA ... 1 A |
| connection type of remote signaling contact | M2 |
| connectable conductor cross-section for remote signaling contacts for rigid conductor | 0.14 ... 1.5 mm2 |
| AWG number as coded connectable conductor cross section for remote signaling contacts | 28 ... 16 |
| tightening torque for remote signaling contacts | 0.25 N·m |
| stripped length of the cable for remote signaling contacts | 7 mm |
NEMA/UL - Data 2
| type of distribution system | TN-S, TT |
|---|---|
| ambient temperature during operation | -40 ... +80 °C |
Logistics 7
| Net weight | 0.42 kg |
|---|---|
| Package dimensions | 77 × 95 × 82 mm |
| Country of origin | DE |
| Shipping weight | 0.92 kg |
| Ships from | Türkiye |
| Dispatch | 16 Nov |
| Stock | Low stock |
Source: manufacturer data · Last verified: 31 Oct 2026
Documents
Documents for 5SD7464-1 1
-
Datasheet
ProductDownload PDF: Product data sheet 5SD7464-1
Product data sheet 5SD7464-1
Certifications
Certifications and standards
- IEC 61643-11
- EN 61643-11
Quick answers
Questions about the 5SD7464-1
Which supply voltage is 5SD7464-1 rated for?
The rated operational voltage of 5SD7464-1 is 350 V AC.
What is the EAN of 5SD7464-1?
The EAN (GTIN) of 5SD7464-1 is 4001869340630.
Where does 5SD7464-1 ship from, and how fast?
5SD7464-1 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
Reviews
Customer reviews
Series
Siemens 5SD7
- Brand
- Siemens
- Series
- 5SD7