Siemens 3UF8011-2AB00-0 3UF8 24V Motor Controller

Rated operational voltage
24 V AC
EAN
4047621120249
Description

About the M-CP

The Siemens 3UF8011-2AB00-0 is a motor controller from the SENTRON/SIRIUS 3UF8 series. Basic device SIMOCODE M-CP MCC, Single Pair Ethernet 10BASE-T1L IEEE 802.3cg SPE, PROFINET IO, OPC UA and web server, 1 bus connection 3-pole terminal, Us: 24 V DC, 6 I/4 O freely configurable, input for thermistor, input for ground fault transformer 3UL23. Supplied by Stoklink for industrial and commercial low-voltage applications.

Certifications & Standards

  • UL2302-1
  • UL2303-1
  • UL2304-1
  • UL2305-1
  • UL2306-1
  • UL2307-1

Applications & Use Cases

The Siemens 3UF8011-2AB00-0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3UF8 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.

Specification

Full specification

224 values · Last verified 31 Oct 2026

General 9

product brand name SIMOCODE
product designation Motor management system
product type designation M-CP
manufacturer's article number: 1 of residual current transformer connectable 3UL2302-1A
manufacturer's article number: 2 of residual current transformer connectable 3UL2303-1A
manufacturer's article number: 3 of residual current transformer connectable 3UL2304-1A
manufacturer's article number: 4 of residual current transformer connectable 3UL2305-1A
manufacturer's article number: 5 of residual current transformer connectable 3UL2306-1A
manufacturer's article number: 6 of residual current transformer connectable 3UL2307-1A

General technical data 50

certificate of suitability CE / RoHS
product function: current measurement No
product function: voltage measurement No
product function: active power measurement Yes
product function: energy measurement No
product function: frequency measurement No
product function: bus communication Yes
product function: automatic start Yes
product function: data acquisition function Yes
product function: diagnostics function Yes
product function: residual current display Yes
product function: password protection Yes
product function: test function Yes
product function: maintenance function Yes
product function: MRRT redundancy procedure No
product feature protective coating on printed-circuit board No; on request
product component: input for thermistor connection Yes
product component: digital input Yes
product component: input for residual current converter Yes
product component: input for analog temperature sensors No
product component: input for ground fault detection Yes
product component: relay output Yes
product extension: temperature monitoring module No
product extension: current measuring module No
product extension: current/voltage measuring module Yes
product extension: fail-safe digital I/O module No
product extension: ground-fault monitoring module No
product extension: decoupling module No
product extension: analog I/O module No
product extension: digital I/O module with monostable outputs No
product extension: digital I/O module with bistable outputs No
product extension: control unit with display Yes
product extension: control unit No
apparent power consumption 6 V·A
consumed active power 3 W
insulation voltage with degree of pollution 3 at AC rated value 250 V
surge voltage resistance rated value 4 000 V
shock resistance: according to IEC 60068-2-27 15 g / 11 ms
shock resistance: vibration resistance 1 ... 6 Hz / 15 mm; 6 ... 500 Hz / 2 g
switching capacity current of the NO contacts of the relay outputs at AC-15: at 24 V 6 A
mechanical service life (operating cycles) typical 10 000 000
electrical endurance (operating cycles) typical 100 000
buffering time in the event of power failure 0.2 s
adjustable current response value current 1 initial value 0.03 A
adjustable current response value current 1 full-scale value 40 A
reference code according to IEC 81346-2 F
continuous current of the NO contacts of the relay outputs: at 50 °C 6 A
type of input characteristic Type 1 in accordance with EN 61131-2
Substance Prohibitance (day/month/year) 01/01/2024
SVHC substance name Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1 4,4'-isopropylidenediphenol (Bisphenol A, BPA) CAS-No. 80-05-7

Sensor 2

measurable line frequency initial value 20 Hz
measurable line frequency full-scale value 120 Hz
Show all 224 specifications ↓ Show less ↑163 more values in Identification, Electromagnetic compatibility, Inputs/ Outputs, Protective and monitoring functions, Motor control functions, Communication/ Protocol, Installation/ mounting/ dimensions, Connections/ Terminals, Ambient conditions, Short-circuit protection, Electrical Safety, ATEX, Galvanic isolation, Main circuit, Control circuit/ Control, Logistics.

Identification 10

Part number 3UF8011-2AB00-0
Type designation M-CP
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4047621120249
ETIM class EC002572
eCl@ss 27370804

Electromagnetic compatibility 10

EMC emitted interference according to IEC 60947-1 class A
EMC immunity according to IEC 60947-1 corresponds to degree of severity 3
conducted interference: due to burst according to IEC 61000-4-4 2 kV (power ports) / 1 kV (signal ports)
conducted interference: due to conductor-earth surge according to IEC 61000-4-5 2 kV
conducted interference: due to conductor-conductor surge according to IEC 61000-4-5 1 kV
conducted interference: due to high-frequency radiation according to IEC 61000-4-6 10 V
field-based interference according to IEC 61000-4-3 10 V/m
electrostatic discharge according to IEC 61000-4-2 6 kV contact discharge / 8 kV air discharge
conducted HF interference emissions according to CISPR11 corresponds to degree of severity A
field-bound HF interference emission according to CISPR11 corresponds to degree of severity A

Inputs/ Outputs 20

product function: parameterizable inputs Yes
product function: parameterizable outputs Yes
number of inputs 6
for thermistor connection 1
number of digital inputs with a common reference potential 6
digital input version: type 1 acc. to IEC 61131 Yes
digital input version: type 2 acc. to IEC 61131 No
number of analog inputs 0
number of sensor inputs for ground fault detection 1
input voltage at digital input at DC: rated value 24 V
number of outputs 4
number of semiconductor outputs 0
number of outputs as contact-affected switching element 4
number of analog outputs 0
switching behavior monostable
number of relay outputs 4
type of relay outputs Monostable
wire length for digital signals maximum 600 m
wire length between sensor and electronics evaluation device with Cu 1.5 mm2 and 150 nF/km maximum 400 m
wire length for thermistor connection: with conductor cross-section = 0.5 mm2 maximum 50 m

Protective and monitoring functions 25

product function: asymmetry detection Yes
product function: blocking current evaluation Yes
product function: power factor monitoring Yes
product function: ground fault detection Yes
product function: ground-fault monitoring Yes
product function: phase failure detection Yes
product function: phase sequence recognition Yes
product function: voltage detection Yes
product function: monitoring of number of start operations Yes
product function: overvoltage detection Yes
product function: overcurrent detection 1 phase Yes
product function: undervoltage detection Yes
product function: undercurrent detection 1 phase Yes
product function: active power monitoring Yes
type of current for monitoring AC current and pulsating DC current (type A) acc. to IEC 62020-1
response time maximum 100 ms
diagnostics function at sensor input with residual current transformer short-circuit detection Yes
relative measurement deviation of residual current transformer 2.5 %
product function: current detection Yes
product function: overload protection Yes
product function: evaluation of thermistor motor protection Yes
total cold resistance number of sensors in series maximum 1.5 kΩ
response value of thermoresistor 3 400 ... 3 800 Ω
of the short-circuit control 9Ω
release value of thermoresistor 1 500 ... 1 650 Ω

Motor control functions 12

product function: parameterizable overload relay Yes
product function: circuit breaker control Yes
product function: direct start Yes
product function: reverse starting Yes
product function: star-delta circuit Yes
product function: star-delta reversing circuit Yes
product function: Dahlander circuit Yes
product function: Dahlander reversing circuit No
product function: pole-changing switch circuit Yes
product function: pole-changing switch reversing circuit Yes
product function: slide control Yes
product function: valve control Yes

Communication/ Protocol 31

protocol is supported: PROFIBUS DP protocol No
protocol is supported: PROFINET IO protocol Yes
protocol is supported: PROFIsafe protocol No
protocol is supported: Modbus RTU No
protocol is supported: Modbus TCP Yes
protocol is supported: EtherNet/IP Yes
protocol is supported: OPC UA Server Yes
protocol is supported: LLDP Yes
protocol is supported: Address Resolution Protocol (ARP) Yes
protocol is supported: SNMP Yes
protocol is supported: HTTPS Yes
protocol is supported: NTP Yes
protocol is supported: Media Redundancy Protocol (MRP) No
product function: web server Yes
product function: shared device Yes
product function: at the Ethernet interface Autocrossover No
product function: at the Ethernet interface Autonegotiation Yes
product function: at the Ethernet interface Autosensing No
product function: Media Redundancy Protocol for Planned Duplication (MRPD) No
product function: is supported Device Level Ring (DLR) No
product function: is supported PROFINET system redundancy (S2) Yes
product function: supports PROFIenergy measured values No
product function: supports PROFIenergy shutdown No
transfer rate 10 Mbit/s
transfer rate maximum 10 Mbit/s
PROFINET conformity class B
identification & maintenance function: I&M0 - device-specific information Yes
identification & maintenance function: I&M1 - higher level designation/location designation Yes
identification & maintenance function: I&M2 - installation date Yes
identification & maintenance function: I&M3 - comment Yes
type of electrical connection of the communication interface spring-loaded terminal (push-in)

Installation/ mounting/ dimensions 9

mounting position any
fastening method screw and snap-on mounting
height 65.6 mm
width 118 mm
depth 77.5 mm
required spacing: top 10 mm
required spacing: bottom 20 mm
required spacing: left 0 mm
required spacing: right 0 mm

Connections/ Terminals 14

product component removable terminal for auxiliary and control circuit Yes
type of electrical connection: for auxiliary and control circuit spring-loaded terminals (push-in)
type of electrical connection: of the relay outputs spring-loaded terminal (push-in)
type of electrical connection: of the thermistor connection spring-loaded terminal (push-in)
type of electrical connection: of the fail-safe digital input spring-loaded terminal (push-in)
type of electrical connection: of the connection for ground fault input spring-loaded terminal (push-in)
type of electrical connection: of the 1-Wire® connection spring-loaded terminal (push-in)
type of electrical connection: of Industrial Ethernet interface spring-loaded terminal (push-in)
type of connectable conductor cross-sections: for supply voltage for AWG cables solid 1x (24 ... 12)
type of connectable conductor cross-sections: of the relay outputs solid 1x (0.2 ... 2.5 mm2)
type of connectable conductor cross-sections: of the 1-Wire® connection solid 1x (0.2 ... 1.5 mm2)
type of connectable conductor cross-sections: of the connection for ground fault input solid 1x (0.2 ... 1.5 mm2)
type of connectable conductor cross-sections: of the fail-safe digital input solid 1x (0.2 ... 1.5 mm2)
type of connectable conductor cross-sections: of the thermistor connection solid 1x (0.2 ... 1.5 mm2)

Ambient conditions 9

installation altitude at height above sea level maximum 2 000 m
ambient temperature: during operation -25 ... +60 °C
ambient temperature: during storage -40 ... +80 °C
ambient temperature: during transport -40 ... +80 °C
environmental category: during operation according to IEC 60721 3K24 (condensation occasionally, no precipitation, no water, no ice formation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3B2, 3S5 (sand must not enter the device), 3M6
environmental category: during storage according to IEC 60721 1K22 (condensation occasionally, no precipitation, no water, no ice formation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1B2, 1S10 (sand must not enter the device), 1M4
environmental category: during transport according to IEC 60721 2K12 (no condensation, no thermal shock), 2C1 (no salt mist), 2B2, 2S1, 2M2
relative humidity: during operation 5 ... 95 %
contact rating of auxiliary contacts according to UL B300 / R300

Short-circuit protection 1

design of short-circuit protection per output fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit breaker C-Char: 2 A (@1 kA) and 6 A (I_K < 500 A)

Electrical Safety 1

touch protection against electrical shock finger-safe

ATEX 3

certificate of suitability: IECEx Yes; IECEX BVS 25.0051 X
certificate of suitability: according to ATEX directive 2014/34/EU BVS 25 ATEX F001 X
explosion device group and category according to ATEX directive 2014/34/EU I (M2), II (2) G, II (2) D / I (M2), II (1/2) G, II (1G/2D)

Galvanic isolation 2

(electrically) protective separation according to IEC 60947-1 all circuits with protective separation (double clearances and creepage distances)
design of the electrical isolation Protective separation in accordance with IEC 60947-1 for all circuits

Main circuit 1

operating frequency rated value 50 ... 60 Hz

Control circuit/ Control 8

product function soft starter control Yes
type of voltage of the control supply voltage DC
relative symmetrical tolerance of the control supply voltage frequency 5%
control supply voltage at DC rated value 24 V
control supply voltage 1 at DC rated value 24 V
operating range factor control supply voltage rated value at DC: initial value 0.8
inrush current peak: at 24 V 1.7 A
duration of inrush current peak: at 24 V 7.5 ms

Logistics 7

Net weight 0.35 kg
Package dimensions 138 × 103 × 76 mm
Country of origin CZ
Shipping weight 0.85 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 31 Oct 2026

Documents

Documents for 3UF8011-2AB00-0

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • UL2302-1
  • UL2303-1
  • UL2304-1
  • UL2305-1
  • UL2306-1
  • UL2307-1
Quick answers

Questions about the M-CP

Which supply voltage is M-CP rated for?

The rated operational voltage of M-CP is 24 V AC.

What is the EAN of M-CP?

The EAN (GTIN) of M-CP is 4047621120249.

Where does M-CP ship from, and how fast?

M-CP ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for motor starters

All guides for motor starters
Reviews

Customer reviews

Series

Siemens 3UF8

Brand
Siemens
Series
3UF8
2,854.56 SR On request
Get a Quote
Quote

Get a Quote

M-CP

Genuine parts

Genuine, factory-sealed parts

Siemens · 3UF8011-2AB00-0

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart