About the DM-FL

The Siemens 3UF7320-1AB00-0 is a motor controller from the SENTRON/SIRIUS 3UF7 series. Fail-safe digital module DM-F local, for fail-safe shutdown via hardware signal Us: 24 V DC 2 relay enabling circuits, 2 relay outputs, safety function can be set via DIP switch, maximum achievable SIL IEC 61508: 3, maximum achievable PL ISO 13849-1: E. Supplied by Stoklink for industrial and commercial low-voltage applications.

Certifications & Standards

  • IEC 61508
  • EN 61131-2
  • IEC 60947-1

Applications & Use Cases

The Siemens 3UF7320-1AB00-0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3UF7 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.

Specification

Full specification

164 values · Last verified 31 Oct 2026

General 4

product brand name SIMOCODE
product designation Fail-safe digital module
design of the product for emergency off and safety doors
product type designation DM-FL

General technical data 40

product function: EMERGENCY OFF function Yes
product function: automatic start Yes
product function: light barrier monitoring Yes
product function: light array monitoring Yes
product function: protective door monitoring Yes
product function: magnetically operated switch monitoring NC-NO Yes
product function: pressure-sensitive mat monitoring Yes
product function: monitored start-up Yes
product component: input for thermistor connection No
product component: digital input Yes
product component: input for analog temperature sensors No
product component: input for ground fault detection No
product component: relay output Yes
consumed active power 3 W
insulation voltage with degree of pollution 3 at AC rated value 300 V
surge voltage resistance rated value 4 000 V
shock resistance according to IEC 60068-2-27 15 g / 11 ms
vibration resistance according to IEC 60068-2-6 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2 g
operating frequency maximum 360 1/y
switching capacity current of the NO contacts of the relay outputs at AC-15: at 24 V 3 A
switching capacity current of relay enabling circuits at AC-15: at 24 V 3 A
switching capacity current of relay enabling circuits at DC-13: at 24 V 4 A
mechanical service life (operating cycles) typical 10 000 000
electrical endurance (operating cycles) typical 100 000
buffering time in the event of power failure 60 ms
recovery time: after power failure typical 8 s
recovery time: after opening of the safety circuits typical 250 ms
make time with automatic start: typical 50 ms
make time with automatic start: maximum 100 ms
make time with automatic start: at DC maximum 100 ms
make time with automatic start: after power failure typical 8 000 ms
make time with automatic start: after power failure maximum 8 200 ms
backslide delay time after opening of the safety circuits typical 50 ms
backslide delay time in the event of power failure: typical 40 ms
backslide delay time in the event of power failure: maximum 80 ms
reference code according to IEC 81346-2 F
reference code according to IEC 81346-2:2019 F
type of input characteristic Type 2 in accordance with EN 61131-2
Substance Prohibitance (day/month/year) 05/01/2012
SVHC substance name Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868- 10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1

Electromagnetic compatibility 10

EMC emitted interference according to IEC 60947-1 class A
EMC immunity according to IEC 60947-1 corresponds to degree of severity 3
conducted interference: due to burst according to IEC 61000-4-4 2 kV network connection / 1 kV control connection
conducted interference: due to conductor-earth surge according to IEC 61000-4-5 1 kV
conducted interference: due to conductor-conductor surge according to IEC 61000-4-5 0.5 kV
conducted interference: due to high-frequency radiation according to IEC 61000-4-6 10 V
field-based interference according to IEC 61000-4-3 10 V/m
electrostatic discharge according to IEC 61000-4-2 6 kV contact discharge / 8 kV air discharge
conducted HF interference emissions according to CISPR11 corresponds to degree of severity A
field-bound HF interference emission according to CISPR11 corresponds to degree of severity A
Show all 164 specifications ↓ Show less ↑110 more values in Identification, Inputs/ Outputs, Product Function, Installation/ mounting/ dimensions, Connections/ Terminals, Ambient conditions, Short-circuit protection, Safety related data, (λdd), IEC 62061, ISO 13849, IEC 61508, Electrical Safety, ATEX, Galvanic isolation, Control circuit/ Control, Logistics.

Identification 10

Part number 3UF7320-1AB00-0
Type designation DM-FL
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4011209780828
ETIM class EC002613
eCl@ss 27370805

Inputs/ Outputs 24

product function: parameterizable inputs Yes
product function: parameterizable outputs Yes
number of inputs 5
design of input: cascading input/functional switching Yes
design of input: feedback input Yes
design of input: start input Yes
pulse duration: of the sensor input minimum 30 ms
pulse duration: of the ON pushbutton input minimum 0.2 s
pulse duration: of the cascading input minimum 0.2 s
number of digital inputs 0
with a common reference potential 4
digital input version: type 1 acc. to IEC 61131 No
digital input version: type 2 acc. to IEC 61131 Yes
number of analog inputs 0
number of sensor inputs: 1-channel or 2-channel 1
number of sensor inputs: 2-channel 1
number of outputs 2
number of semiconductor outputs 0
number of outputs as contact-affected switching element: ● 2
number of outputs as contact-affected switching element: as NO contact safety-related instantaneous contact 2
number of analog outputs 0
switching behavior monostable
property of contacts of the relay outputs Fail-safe NO contacts
wire length for digital signals maximum 1 500 m

Product Function 8

suitability for use: position switch monitoring Yes
suitability for use: EMERGENCY-OFF circuit monitoring Yes
suitability for use: valve monitoring No
suitability for use: opto-electronic protection device monitoring Yes
suitability for use: tactile sensor monitoring No
suitability for use: magnetically operated switch monitoring Yes
suitability for use: proximity switch monitoring No
suitability for use: safety-related circuits Yes

Installation/ mounting/ dimensions 9

mounting position any
fastening method screw and snap-on mounting
height 106 mm
width 45 mm
depth 124 mm
required spacing: top 40 mm
required spacing: bottom 40 mm
required spacing: left 0 mm
required spacing: right 0 mm

Connections/ Terminals 7

product component removable terminal for auxiliary and control circuit Yes
type of electrical connection for auxiliary and control circuit screw-type terminals
type of connectable conductor cross-sections: solid 1x (0.5 ... 4.0mm2), 2x (0.5 ... 2.5 mm2)
type of connectable conductor cross-sections: finely stranded with core end processing 1x (0.5 ... 2.5 mm2), 2x (0.5 ... 1.5 mm2)
type of connectable conductor cross-sections: for AWG cables solid 1x (20 ... 12), 2x (20 ... 14)
tightening torque with screw-type terminals 0.8 ... 1.2 N·m
tightening torque [lbf·in] with screw-type terminals 7 ... 10.3 lbf·in

Ambient conditions 11

installation altitude at height above sea level: 1 maximum 2 000 m
installation altitude at height above sea level: 2 maximum 3 000 m; max. +50 °C (no protective separation)
installation altitude at height above sea level: 3 maximum 4 000 m; max. +40 °C (no protective separation)
ambient temperature: during operation -25 ... +60 °C
ambient temperature: during storage -40 ... +80 °C
ambient temperature: during transport -40 ... +80 °C
environmental category: during operation according to IEC 60721 3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
environmental category: during storage according to IEC 60721 1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4
environmental category: during transport according to IEC 60721 2K2, 2C1, 2S1, 2M2
relative humidity during operation 5 ... 95 %
contact rating of auxiliary contacts according to UL B300 / R300

Short-circuit protection 1

design of the fuse link for short-circuit protection of relay enabling circuits required gL/gG: 4 A

(λdd) 3

failure rate [FIT] at rate of non-recognizable hazardous failures (λdu) 7 FIT
average diagnostic coverage level (DCavg): at single-channel evaluation 90 %
average diagnostic coverage level (DCavg): at 2-channel evaluation 99 %

IEC 62061 2

Safety Integrity Level (SIL): at single-channel evaluation according to IEC 62061 1
Safety Integrity Level (SIL): at 2-channel evaluation according to IEC 62061 3

ISO 13849 4

performance level (PL): at single-channel evaluation according to ISO 13849-1 d
performance level (PL): at 2-channel evaluation according to ISO 13849-1 e
category: at single-channel evaluation according to ISO 13849-1 2
category: at 2-channel evaluation according to ISO 13849-1 4

IEC 61508 9

Safety Integrity Level (SIL): at single-channel evaluation according to IEC 61508 1
Safety Integrity Level (SIL): at 2-channel evaluation according to IEC 61508 3
safety device type according to IEC 61508-2 Type B
PFDavg with low demand rate: at single-channel evaluation according to IEC 61508 0.00065
PFDavg with low demand rate: at 2-channel evaluation according to IEC 61508 2E-5
Safe failure fraction (SFF) 99 %
hardware fault tolerance: at single-channel evaluation according to IEC 61508 0
hardware fault tolerance: at 2-channel evaluation according to IEC 61508 1
T1 value for proof test interval or service life according to IEC 61508 20 a

Electrical Safety 1

touch protection against electrical shock finger-safe

ATEX 2

certificate of suitability according to ATEX directive 2014/34/EU BVS 06 ATEX F001
explosion device group and category according to ATEX directive 2014/34/EU II (2) G, II (2 ) D, I (M2)

Galvanic isolation 2

(electrically) protective separation according to IEC 60947-1 All circuits in SIMOCODE pro are with protective separation, i.e. they are designed with doubled creepage paths and clearances. NOTICE: The information in the "Protective Separation" test report, No. 2668, must be observed.
design of the electrical isolation Protective separation in accordance with IEC 60947-1 for all circuits, up to installation altitude of 2000 m

Control circuit/ Control 5

type of voltage of the control supply voltage DC
control supply voltage at DC rated value 24 V
operating range factor control supply voltage rated value at DC: initial value 0.8
inrush current peak: at 24 V 8.3 A
duration of inrush current peak: at 24 V 1 ms

Logistics 7

Net weight 0.319 kg
Package dimensions 136 × 115 × 65 mm
Country of origin DE
Shipping weight 0.819 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 31 Oct 2026

Documents

Documents for 3UF7320-1AB00-0

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • IEC 61508
  • EN 61131-2
  • IEC 60947-1
Quick answers

Questions about the DM-FL

Which supply voltage is DM-FL rated for?

The rated operational voltage of DM-FL is 24 V AC.

What is the EAN of DM-FL?

The EAN (GTIN) of DM-FL is 4011209780828.

Where does DM-FL ship from, and how fast?

DM-FL ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for motor starters

All guides for motor starters
Reviews

Customer reviews

Series

Siemens 3UF7

Brand
Siemens
Series
3UF7
1,666.06 SR On request
Get a Quote
Quote

Get a Quote

DM-FL

Genuine parts

Genuine, factory-sealed parts

Siemens · 3UF7320-1AB00-0

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart