The Siemens 3UF7300-1AB00-0 is a motor controller from the SENTRON/SIRIUS 3UF7 series. Digital module, 4 inputs and 2 relay outputs, input voltage 24 V DC, relay outputs monostable, max. 2 digital modules, for SIMOCODE pro V basic unit. Supplied by Stoklink for industrial and commercial low-voltage applications.
The Siemens 3UF7300-1AB00-0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3UF7 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.
| product brand name | SIMOCODE |
|---|---|
| product designation | digital modules |
| product type designation | DM mono |
| product component: input for thermistor connection | No |
|---|---|
| product component: digital input | Yes |
| product component: input for analog temperature sensors | No |
| product component: input for ground fault detection | No |
| product component: relay output | Yes |
| consumed active power | 0.7 W |
| insulation voltage with degree of pollution 3 at AC rated value | 300 V |
| surge voltage resistance rated value | 4 000 V |
| shock resistance according to IEC 60068-2-27 | 15 g / 11 ms |
| vibration resistance according to IEC 60068-2-6 | 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2 g |
| switching capacity current of the NO contacts of the relay outputs at AC-15: at 24 V | 6 A |
| mechanical service life (operating cycles) typical | 10 000 000 |
| electrical endurance (operating cycles) typical | 100 000 |
| reference code according to IEC 81346-2 | K |
| reference code according to IEC 81346-2:2019 | K |
| continuous current of the NO contacts of the relay outputs: at 50 °C | 6 A |
| Substance Prohibitance (day/month/year) | 05/01/2012 |
| SVHC substance name | Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868- 10-5 Melamine CAS-No. 108-78-1 |
| EMC emitted interference according to IEC 60947-1 | class A |
|---|---|
| EMC immunity according to IEC 60947-1 | corresponds to degree of severity 3 |
| conducted interference: due to burst according to IEC 61000-4-4 | 1 kV |
| conducted interference: due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| conducted interference: due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| conducted interference: due to high-frequency radiation according to IEC 61000-4-6 | 10 V |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| electrostatic discharge according to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
| conducted HF interference emissions according to CISPR11 | corresponds to degree of severity A |
| field-bound HF interference emission according to CISPR11 | corresponds to degree of severity A |
| Part number | 3UF7300-1AB00-0 |
|---|---|
| Type designation | DM mono |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4011209606197 |
| ETIM class | EC002613 |
| eCl@ss | 27370805 |
| product function: parameterizable inputs | Yes |
|---|---|
| product function: parameterizable outputs | Yes |
| number of inputs | 4 |
| number of digital inputs | 4 |
| with a common reference potential | 4 |
| digital input version: type 1 acc. to IEC 61131 | No |
| digital input version: type 2 acc. to IEC 61131 | Yes |
| number of analog inputs | 0 |
| input voltage at digital input at DC rated value | 24 V |
| number of outputs | 2 |
| number of semiconductor outputs | 0 |
| number of outputs as contact-affected switching element | 2 |
| number of analog outputs | 0 |
| switching behavior | monostable |
| property of contacts of the relay outputs | Floating NO contacts (NC reaction parameterizable via internal signal conditioning), connected to common ground, can be freely assigned to the control functions (e.g. line, star (wye), delta contactor or signaling of the operating state) |
| wire length for digital signals maximum | 300 m |
| mounting position | any |
|---|---|
| fastening method | screw and snap-on mounting |
| height | 92 mm |
| width | 22.5 mm |
| depth | 124 mm |
| required spacing: top | 40 mm |
| required spacing: bottom | 40 mm |
| required spacing: left | 0 mm |
| required spacing: right | 0 mm |
| product component removable terminal for auxiliary and control circuit | Yes |
|---|---|
| type of electrical connection for auxiliary and control circuit | screw-type terminals |
| type of connectable conductor cross-sections: solid | 1x (0.5 ... 4.0mm2), 2x (0.5 ... 2.5 mm2) |
| type of connectable conductor cross-sections: finely stranded with core end processing | 1x (0.5 ... 2.5 mm2), 2x (0.5 ... 1.5 mm2) |
| type of connectable conductor cross-sections: for AWG cables solid | 1x (20 ... 14), 2x (20 ... 16) |
| tightening torque with screw-type terminals | 0.8 ... 1.2 N·m |
| tightening torque [lbf·in] with screw-type terminals | 7 ... 10.3 lbf·in |
| installation altitude at height above sea level: 1 maximum | 2 000 m |
|---|---|
| installation altitude at height above sea level: 2 maximum | 3 000 m; max. +50 °C (no protective separation) |
| installation altitude at height above sea level: 3 maximum | 4 000 m; max. +40 °C (no protective separation) |
| ambient temperature: during operation | -25 ... +60 °C |
| ambient temperature: during storage | -40 ... +80 °C |
| ambient temperature: during transport | -40 ... +80 °C |
| environmental category: during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| environmental category: during storage according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| environmental category: during transport according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| relative humidity during operation | 5 ... 95 % |
| contact rating of auxiliary contacts according to UL | B300 / R300 |
| design of short-circuit protection per output | Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit- breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A) |
|---|
| touch protection against electrical shock | finger-safe |
|---|
| certificate of suitability according to ATEX directive 2014/34/EU | BVS 06 ATEX F001 |
|---|---|
| explosion device group and category according to ATEX directive 2014/34/EU | II (2) G, II (2 ) D, I (M2) |
| (electrically) protective separation according to IEC 60947-1 | All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information) |
|---|
| type of voltage of the control supply voltage | DC |
|---|---|
| control supply voltage at DC rated value | 24 V |
| operating range factor control supply voltage rated value at DC: initial value | 0.8 |
| Net weight | 0.123 kg |
|---|---|
| Package dimensions | 110 × 30 × 150 mm |
| Country of origin | DE |
| Shipping weight | 0.623 kg |
| Ships from | Türkiye |
| Dispatch | 16 Nov |
| Stock | Low stock |
Source: manufacturer data · Last verified: 31 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of DM mono is 24 V AC.
The EAN (GTIN) of DM mono is 4011209606197.
DM mono ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.