IEC 60947-4-1 Standards for Contactors and Motor Starters Explained
Master AC-3 rating selection under IEC 60947-4-1 for contactors and motor starters, including utilization categories and coordination types. Shop at Stoklink.
The Siemens 3UF7013-1AB00-0 is a motor controller from the SENTRON/SIRIUS 3UF7 series. Basic device SIMOCODE pro V EIP, EtherNet/IP, media redundancy, DLR (max. 20 participants) web server, transfer rate 100 Mbps, 2 x bus connection via RJ45, 4 I/3 O freely configurable, Us: 24 V DC, input for thermistor connection monostable relay outputs, expandable by expansion modules. Supplied by Stoklink for industrial and commercial low-voltage applications.
The Siemens 3UF7013-1AB00-0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3UF7 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.
| product brand name | SIMOCODE |
|---|---|
| product designation | Motor management system |
| design of the product | basic unit 3 |
| product type designation | pro V EIP |
| product function: current measurement | No |
|---|---|
| product function: voltage measurement | No |
| product function: active power measurement | Yes |
| product function: energy measurement | No |
| product function: frequency measurement | No |
| product function: bus communication | Yes |
| product function: data acquisition function | Yes |
| product function: diagnostics function | Yes |
| product function: password protection | Yes |
| product function: test function | Yes |
| product function: maintenance function | Yes |
| product function: MRRT redundancy procedure | No |
| product component: input for thermistor connection | Yes |
| product component: digital input | Yes |
| product component: input for analog temperature sensors | No |
| product component: input for ground fault detection | No |
| product component: relay output | Yes |
| product extension: temperature monitoring module | Yes |
| product extension: current measuring module | Yes |
| product extension: current/voltage measuring module | Yes |
| product extension: fail-safe digital I/O module | Yes |
| product extension: ground-fault monitoring module | Yes |
| product extension: decoupling module | Yes |
| product extension: analog I/O module | Yes |
| product extension: digital I/O module with monostable outputs | Yes |
| product extension: digital I/O module with bistable outputs | Yes |
| product extension: control unit with display | Yes |
| product extension: control unit | Yes |
| consumed active power | 3.9 W |
| insulation voltage with degree of pollution 3 at AC rated value | 300 V |
| surge voltage resistance rated value | 4 000 V |
| shock resistance: according to IEC 60068-2-27 | 15 g / 11 ms |
| shock resistance: vibration resistance | 1 ... 6 Hz / 15 mm; 6 ... 500 Hz / 2 g |
| switching capacity current of the NO contacts of the relay outputs at AC-15: at 24 V | 6 A |
| mechanical service life (operating cycles) typical | 10 000 000 |
| electrical endurance (operating cycles) typical | 100 000 |
| buffering time in the event of power failure | 0.02 s |
| reference code according to IEC 81346-2 | F |
| continuous current of the NO contacts of the relay outputs: at 50 °C | 6 A |
| type of input characteristic | Type 1 in accordance with EN 61131-2 |
| Substance Prohibitance (day/month/year) | 03/01/2017 |
| SVHC substance name | Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868- 10-5 Melamine CAS-No. 108-78-1 4,4'-isopropylidenediphenol (Bisphenol A, BPA) CAS-No. 80-05-7 |
| EMC emitted interference according to IEC 60947-1 | class A |
|---|---|
| EMC immunity according to IEC 60947-1 | corresponds to degree of severity 3 |
| conducted interference: due to burst according to IEC 61000-4-4 | 2 kV (power ports) / 1 kV (signal ports) |
| conducted interference: due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| conducted interference: due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| conducted interference: due to high-frequency radiation according to IEC 61000-4-6 | 10 V |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| electrostatic discharge according to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
| conducted HF interference emissions according to CISPR11 | corresponds to degree of severity A |
| field-bound HF interference emission according to CISPR11 | corresponds to degree of severity A |
| Part number | 3UF7013-1AB00-0 |
|---|---|
| Type designation | pro V EIP |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047621014852 |
| ETIM class | EC002572 |
| eCl@ss | 27370804 |
| product function: parameterizable inputs | Yes |
|---|---|
| product function: parameterizable outputs | Yes |
| number of inputs | 4 |
| for thermistor connection | 1 |
| number of digital inputs with a common reference potential | 4 |
| digital input version: type 1 acc. to IEC 61131 | Yes |
| input voltage at digital input at DC: rated value | 24 V |
| number of outputs | 3 |
| number of semiconductor outputs | 0 |
| number of outputs as contact-affected switching element | 3 |
| switching behavior | monostable |
| number of relay outputs | 3 |
| type of relay outputs | Monostable |
| wire length for digital signals maximum | 300 m |
| wire length for thermistor connection: with conductor cross-section = 0.5 mm2 maximum | 50 m |
| product function: asymmetry detection | Yes |
|---|---|
| product function: blocking current evaluation | Yes |
| product function: power factor monitoring | Yes |
| product function: ground fault detection | Yes |
| product function: ground-fault monitoring | No |
| product function: phase failure detection | Yes |
| product function: phase sequence recognition | Yes |
| product function: voltage detection | Yes |
| product function: monitoring of number of start operations | Yes |
| product function: overvoltage detection | Yes |
| product function: overcurrent detection 1 phase | Yes |
| product function: undervoltage detection | Yes |
| product function: undercurrent detection 1 phase | Yes |
| product function: active power monitoring | Yes |
| product function: current detection | Yes |
| product function: overload protection | Yes |
| product function: evaluation of thermistor motor protection | Yes |
| total cold resistance number of sensors in series maximum | 1.5 kΩ |
| response value of thermoresistor | 3 400 ... 3 800 Ω |
| of the short-circuit control | 9Ω |
| release value of thermoresistor | 1 500 ... 1 650 Ω |
| product function: parameterizable overload relay | Yes |
|---|---|
| product function: circuit breaker control | Yes |
| product function: direct start | Yes |
| product function: reverse starting | Yes |
| product function: star-delta circuit | Yes |
| product function: star-delta reversing circuit | Yes |
| product function: Dahlander circuit | Yes |
| product function: Dahlander reversing circuit | Yes |
| product function: pole-changing switch circuit | Yes |
| product function: pole-changing switch reversing circuit | Yes |
| product function: slide control | Yes |
| product function: valve control | Yes |
| protocol is supported: PROFIBUS DP protocol | No |
|---|---|
| protocol is supported: PROFINET IO protocol | No |
| protocol is supported: PROFIsafe protocol | No |
| protocol is supported: Modbus RTU | No |
| protocol is supported: EtherNet/IP | Yes |
| protocol is supported: OPC UA Server | No |
| protocol is supported: LLDP | Yes |
| protocol is supported: Address Resolution Protocol (ARP) | Yes |
| protocol is supported: SNMP | Yes |
| protocol is supported: HTTPS | No |
| protocol is supported: NTP | Yes |
| protocol is supported: Media Redundancy Protocol (MRP) | No |
| product function: web server | Yes |
| product function: shared device | No |
| product function: at the Ethernet interface Autocrossover | Yes |
| product function: at the Ethernet interface Autonegotiation | Yes |
| product function: at the Ethernet interface Autosensing | Yes |
| product function: is supported Device Level Ring (DLR) | Yes |
| product function: is supported PROFINET system redundancy (S2) | No |
| product function: supports PROFIenergy measured values | No |
| product function: supports PROFIenergy shutdown | No |
| transfer rate maximum | 100 Mbit/s |
| identification & maintenance function: I&M0 - device-specific information | No |
| identification & maintenance function: I&M1 - higher level designation/location designation | No |
| identification & maintenance function: I&M2 - installation date | No |
| identification & maintenance function: I&M3 - comment | No |
| type of electrical connection of the communication interface | 2x RJ45 |
| mounting position | any |
|---|---|
| fastening method | screw and snap-on mounting |
| height | 111 mm |
| width | 45 mm |
| depth | 124 mm |
| required spacing: top | 40 mm |
| required spacing: bottom | 40 mm |
| required spacing: left | 0 mm |
| required spacing: right | 0 mm |
| product component removable terminal for auxiliary and control circuit | Yes |
|---|---|
| type of electrical connection: for auxiliary and control circuit | screw-type terminals |
| type of connectable conductor cross-sections: solid | 1x (0.5 ... 4.0mm2), 2x (0.5 ... 2.5 mm2) |
| type of connectable conductor cross-sections: finely stranded with core end processing | 1x (0.5 ... 2.5 mm2), 2x (0.5 ... 1.5 mm2) |
| type of connectable conductor cross-sections: for AWG cables solid | 1x (20 ... 12), 2x (20 ... 14) |
| tightening torque with screw-type terminals | 0.8 ... 1.2 N·m |
| tightening torque [lbf·in] with screw-type terminals | 7 ... 10.3 lbf·in |
| installation altitude at height above sea level maximum | 2 000 m |
|---|---|
| ambient temperature: during operation | -25 ... +60 °C |
| ambient temperature: during storage | -40 ... +80 °C |
| ambient temperature: during transport | -40 ... +80 °C |
| environmental category: during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| environmental category: during storage according to IEC 60721 | 1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4 |
| environmental category: during transport according to IEC 60721 | 2K2, 2C1, 2S1, 2M2 |
| relative humidity: during operation | 5 ... 95 % |
| contact rating of auxiliary contacts according to UL | B300 / R300 |
| design of short-circuit protection per output | Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit- breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A) |
|---|
| touch protection against electrical shock | finger-safe |
|---|
| certificate of suitability: IECEx | Yes; IECEx BVS 20.0020 / IECEx PTB 18.0004X |
|---|---|
| certificate of suitability: according to ATEX directive 2014/34/EU | BVS 06 ATEX F001, PTB 18 ATEX 5003 X |
| certificate of suitability: acc. to Equipment and Protective System Intended for Use in Potentially Explosive Atmospheres Regulations 2016 (S.I. 2016 No.1107) | ITS21UKEX0464, ITS21UKEX0455X |
| certificate of suitability: according to UKCA | ITS21UKEX0464, ITS21UKEX0455X |
| explosion device group and category according to ATEX directive 2014/34/EU | I (M2), II (2) G, II (2) D / I (M2), II (1/2) G, II (1G/2D) |
| (electrically) protective separation according to IEC 60947-1 | All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information) |
|---|---|
| design of the electrical isolation | Protective separation in accordance with IEC 60947-1 for all circuits |
| product function soft starter control | Yes |
|---|---|
| type of voltage of the control supply voltage | DC |
| control supply voltage at DC rated value | 24 V |
| control supply voltage 1 at DC rated value | 24 V |
| operating range factor control supply voltage rated value at DC: initial value | 0.85 |
| inrush current peak: at 24 V | 17 A |
| duration of inrush current peak: at 24 V | 1.1 ms |
| Net weight | 0.292 kg |
|---|---|
| Package dimensions | 133 × 131 × 55 mm |
| Country of origin | DE |
| Shipping weight | 0.792 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 31 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of pro V EIP is 24 V AC.
The EAN (GTIN) of pro V EIP is 4047621014852.
pro V EIP ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Master AC-3 rating selection under IEC 60947-4-1 for contactors and motor starters, including utilization categories and coordination types. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Size a contactor for a 3-phase motor using IEC 60947-4-1 methodology, AC-3 vs AC-4 categories, NEMA equivalents, and Type 2 coordination. Shop at Stoklink.