Siemens 3UF7013-1AB00-0 3UF7 24V Motor Controller

Rated operational voltage
24 V AC
EAN
4047621014852
Description

About the pro V EIP

The Siemens 3UF7013-1AB00-0 is a motor controller from the SENTRON/SIRIUS 3UF7 series. Basic device SIMOCODE pro V EIP, EtherNet/IP, media redundancy, DLR (max. 20 participants) web server, transfer rate 100 Mbps, 2 x bus connection via RJ45, 4 I/3 O freely configurable, Us: 24 V DC, input for thermistor connection monostable relay outputs, expandable by expansion modules. Supplied by Stoklink for industrial and commercial low-voltage applications.

Certifications & Standards

  • EN 61131-2
  • IEC 60947-5
  • IEC 60947-1

Applications & Use Cases

The Siemens 3UF7013-1AB00-0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3UF7 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.

Specification

Full specification

189 values · Last verified 31 Oct 2026

General 4

product brand name SIMOCODE
product designation Motor management system
design of the product basic unit 3
product type designation pro V EIP

General technical data 42

product function: current measurement No
product function: voltage measurement No
product function: active power measurement Yes
product function: energy measurement No
product function: frequency measurement No
product function: bus communication Yes
product function: data acquisition function Yes
product function: diagnostics function Yes
product function: password protection Yes
product function: test function Yes
product function: maintenance function Yes
product function: MRRT redundancy procedure No
product component: input for thermistor connection Yes
product component: digital input Yes
product component: input for analog temperature sensors No
product component: input for ground fault detection No
product component: relay output Yes
product extension: temperature monitoring module Yes
product extension: current measuring module Yes
product extension: current/voltage measuring module Yes
product extension: fail-safe digital I/O module Yes
product extension: ground-fault monitoring module Yes
product extension: decoupling module Yes
product extension: analog I/O module Yes
product extension: digital I/O module with monostable outputs Yes
product extension: digital I/O module with bistable outputs Yes
product extension: control unit with display Yes
product extension: control unit Yes
consumed active power 3.9 W
insulation voltage with degree of pollution 3 at AC rated value 300 V
surge voltage resistance rated value 4 000 V
shock resistance: according to IEC 60068-2-27 15 g / 11 ms
shock resistance: vibration resistance 1 ... 6 Hz / 15 mm; 6 ... 500 Hz / 2 g
switching capacity current of the NO contacts of the relay outputs at AC-15: at 24 V 6 A
mechanical service life (operating cycles) typical 10 000 000
electrical endurance (operating cycles) typical 100 000
buffering time in the event of power failure 0.02 s
reference code according to IEC 81346-2 F
continuous current of the NO contacts of the relay outputs: at 50 °C 6 A
type of input characteristic Type 1 in accordance with EN 61131-2
Substance Prohibitance (day/month/year) 03/01/2017
SVHC substance name Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868- 10-5 Melamine CAS-No. 108-78-1 4,4'-isopropylidenediphenol (Bisphenol A, BPA) CAS-No. 80-05-7

Electromagnetic compatibility 10

EMC emitted interference according to IEC 60947-1 class A
EMC immunity according to IEC 60947-1 corresponds to degree of severity 3
conducted interference: due to burst according to IEC 61000-4-4 2 kV (power ports) / 1 kV (signal ports)
conducted interference: due to conductor-earth surge according to IEC 61000-4-5 2 kV
conducted interference: due to conductor-conductor surge according to IEC 61000-4-5 1 kV
conducted interference: due to high-frequency radiation according to IEC 61000-4-6 10 V
field-based interference according to IEC 61000-4-3 10 V/m
electrostatic discharge according to IEC 61000-4-2 6 kV contact discharge / 8 kV air discharge
conducted HF interference emissions according to CISPR11 corresponds to degree of severity A
field-bound HF interference emission according to CISPR11 corresponds to degree of severity A
Show all 189 specifications ↓ Show less ↑133 more values in Identification, Inputs/ Outputs, Protective and monitoring functions, Motor control functions, Communication/ Protocol, Installation/ mounting/ dimensions, Connections/ Terminals, Ambient conditions, Short-circuit protection, Electrical Safety, ATEX, Galvanic isolation, Control circuit/ Control, Logistics.

Identification 10

Part number 3UF7013-1AB00-0
Type designation pro V EIP
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4047621014852
ETIM class EC002572
eCl@ss 27370804

Inputs/ Outputs 15

product function: parameterizable inputs Yes
product function: parameterizable outputs Yes
number of inputs 4
for thermistor connection 1
number of digital inputs with a common reference potential 4
digital input version: type 1 acc. to IEC 61131 Yes
input voltage at digital input at DC: rated value 24 V
number of outputs 3
number of semiconductor outputs 0
number of outputs as contact-affected switching element 3
switching behavior monostable
number of relay outputs 3
type of relay outputs Monostable
wire length for digital signals maximum 300 m
wire length for thermistor connection: with conductor cross-section = 0.5 mm2 maximum 50 m

Protective and monitoring functions 21

product function: asymmetry detection Yes
product function: blocking current evaluation Yes
product function: power factor monitoring Yes
product function: ground fault detection Yes
product function: ground-fault monitoring No
product function: phase failure detection Yes
product function: phase sequence recognition Yes
product function: voltage detection Yes
product function: monitoring of number of start operations Yes
product function: overvoltage detection Yes
product function: overcurrent detection 1 phase Yes
product function: undervoltage detection Yes
product function: undercurrent detection 1 phase Yes
product function: active power monitoring Yes
product function: current detection Yes
product function: overload protection Yes
product function: evaluation of thermistor motor protection Yes
total cold resistance number of sensors in series maximum 1.5 kΩ
response value of thermoresistor 3 400 ... 3 800 Ω
of the short-circuit control 9Ω
release value of thermoresistor 1 500 ... 1 650 Ω

Motor control functions 12

product function: parameterizable overload relay Yes
product function: circuit breaker control Yes
product function: direct start Yes
product function: reverse starting Yes
product function: star-delta circuit Yes
product function: star-delta reversing circuit Yes
product function: Dahlander circuit Yes
product function: Dahlander reversing circuit Yes
product function: pole-changing switch circuit Yes
product function: pole-changing switch reversing circuit Yes
product function: slide control Yes
product function: valve control Yes

Communication/ Protocol 27

protocol is supported: PROFIBUS DP protocol No
protocol is supported: PROFINET IO protocol No
protocol is supported: PROFIsafe protocol No
protocol is supported: Modbus RTU No
protocol is supported: EtherNet/IP Yes
protocol is supported: OPC UA Server No
protocol is supported: LLDP Yes
protocol is supported: Address Resolution Protocol (ARP) Yes
protocol is supported: SNMP Yes
protocol is supported: HTTPS No
protocol is supported: NTP Yes
protocol is supported: Media Redundancy Protocol (MRP) No
product function: web server Yes
product function: shared device No
product function: at the Ethernet interface Autocrossover Yes
product function: at the Ethernet interface Autonegotiation Yes
product function: at the Ethernet interface Autosensing Yes
product function: is supported Device Level Ring (DLR) Yes
product function: is supported PROFINET system redundancy (S2) No
product function: supports PROFIenergy measured values No
product function: supports PROFIenergy shutdown No
transfer rate maximum 100 Mbit/s
identification & maintenance function: I&M0 - device-specific information No
identification & maintenance function: I&M1 - higher level designation/location designation No
identification & maintenance function: I&M2 - installation date No
identification & maintenance function: I&M3 - comment No
type of electrical connection of the communication interface 2x RJ45

Installation/ mounting/ dimensions 9

mounting position any
fastening method screw and snap-on mounting
height 111 mm
width 45 mm
depth 124 mm
required spacing: top 40 mm
required spacing: bottom 40 mm
required spacing: left 0 mm
required spacing: right 0 mm

Connections/ Terminals 7

product component removable terminal for auxiliary and control circuit Yes
type of electrical connection: for auxiliary and control circuit screw-type terminals
type of connectable conductor cross-sections: solid 1x (0.5 ... 4.0mm2), 2x (0.5 ... 2.5 mm2)
type of connectable conductor cross-sections: finely stranded with core end processing 1x (0.5 ... 2.5 mm2), 2x (0.5 ... 1.5 mm2)
type of connectable conductor cross-sections: for AWG cables solid 1x (20 ... 12), 2x (20 ... 14)
tightening torque with screw-type terminals 0.8 ... 1.2 N·m
tightening torque [lbf·in] with screw-type terminals 7 ... 10.3 lbf·in

Ambient conditions 9

installation altitude at height above sea level maximum 2 000 m
ambient temperature: during operation -25 ... +60 °C
ambient temperature: during storage -40 ... +80 °C
ambient temperature: during transport -40 ... +80 °C
environmental category: during operation according to IEC 60721 3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
environmental category: during storage according to IEC 60721 1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4
environmental category: during transport according to IEC 60721 2K2, 2C1, 2S1, 2M2
relative humidity: during operation 5 ... 95 %
contact rating of auxiliary contacts according to UL B300 / R300

Short-circuit protection 1

design of short-circuit protection per output Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit- breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A)

Electrical Safety 1

touch protection against electrical shock finger-safe

ATEX 5

certificate of suitability: IECEx Yes; IECEx BVS 20.0020 / IECEx PTB 18.0004X
certificate of suitability: according to ATEX directive 2014/34/EU BVS 06 ATEX F001, PTB 18 ATEX 5003 X
certificate of suitability: acc. to Equipment and Protective System Intended for Use in Potentially Explosive Atmospheres Regulations 2016 (S.I. 2016 No.1107) ITS21UKEX0464, ITS21UKEX0455X
certificate of suitability: according to UKCA ITS21UKEX0464, ITS21UKEX0455X
explosion device group and category according to ATEX directive 2014/34/EU I (M2), II (2) G, II (2) D / I (M2), II (1/2) G, II (1G/2D)

Galvanic isolation 2

(electrically) protective separation according to IEC 60947-1 All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information)
design of the electrical isolation Protective separation in accordance with IEC 60947-1 for all circuits

Control circuit/ Control 7

product function soft starter control Yes
type of voltage of the control supply voltage DC
control supply voltage at DC rated value 24 V
control supply voltage 1 at DC rated value 24 V
operating range factor control supply voltage rated value at DC: initial value 0.85
inrush current peak: at 24 V 17 A
duration of inrush current peak: at 24 V 1.1 ms

Logistics 7

Net weight 0.292 kg
Package dimensions 133 × 131 × 55 mm
Country of origin DE
Shipping weight 0.792 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 31 Oct 2026

Documents

Documents for 3UF7013-1AB00-0

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • EN 61131-2
  • IEC 60947-5
  • IEC 60947-1
Quick answers

Questions about the pro V EIP

Which supply voltage is pro V EIP rated for?

The rated operational voltage of pro V EIP is 24 V AC.

What is the EAN of pro V EIP?

The EAN (GTIN) of pro V EIP is 4047621014852.

Where does pro V EIP ship from, and how fast?

pro V EIP ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for motor starters

All guides for motor starters
Reviews

Customer reviews

Series

Siemens 3UF7

Brand
Siemens
Series
3UF7
3,321.15 SR On request
Get a Quote
Quote

Get a Quote

pro V EIP

Genuine parts

Genuine, factory-sealed parts

Siemens · 3UF7013-1AB00-0

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart