The Schneider Electric LC1E400M7 is a TeSys E series 3-pole AC contactor rated at 400A and 440V, engineered for heavy-duty motor control and industrial power switching applications. Designed for demanding environments, the LC1E400M7 delivers reliable performance in AC-3 and AC-1 utilization categories, making it a trusted choice for motor starter panels, distribution boards, and large-load switching circuits.
| Range | Easy TeSys |
|---|---|
| Range of product | Easy TeSys Control |
| Product or component type | Contactor |
| Device short name | LC1E |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-3 AC-3e AC-1 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
| [Ie] rated operational current | 400 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 330 A (at <55 °C) at <= 440 V AC AC-3e for power circuit 500 A (at <40 °C) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| Motor power kW | 110 kW at 220/230 V AC 50/60 Hz 200 kW at 380/400 V AC 220 kW at 415 V AC 250 kW at 440 V AC 257 kW at 500 V AC 280 kW at 660/690 V AC |
|---|---|
| Pole contact composition | 3 NO |
| [Ith] conventional free air thermal current | 500 A (at 40 °C) for power circuit |
| Irms rated making capacity | 4000 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
| Rated breaking capacity | 3200 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 3600 A 40 °C - 10 s for power circuit |
| Associated fuse rating | 630 A gG at <= 690 V coordination type 1 for power circuit |
| Average impedance | 0.26 mOhm - Ith 500 A 50 Hz for power circuit |
| Power dissipation per pole | 42 W AC-3 65 W AC-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV coil not connected to the power circuit conforming to IEC 60947 |
| Mechanical durability | 4000000 cycles |
| Electrical durability | 250000 cycles AC-1 600000 cycles AC-3 |
| Control circuit type | AC at 50/60 Hz |
| Control circuit voltage limits | 0.85...1.1 Uc (-5...55 °C):operational 50/60 Hz 0.35...0.5 Uc (-5...55 °C):drop-out 50/60 Hz |
| Inrush power in VA | 1075 VA 50 Hz cos phi 0.9 (at 20 °C) 1075 VA 60 Hz cos phi 0.9 (at 20 °C) |
| Hold-in power consumption in VA | 15 VA 50 Hz cos phi 0.9 (at 20 °C) 15 VA 60 Hz cos phi 0.9 (at 20 °C) |
| Heat dissipation | 14 W for control circuit |
| Operating time | 100...170 ms on opening 40...75 ms on closing |
| Maximum operating rate | 2400 cyc/h 55 °C |
| Connections - terminals | Power circuit: cable with lug 2 1...4 mm2 - external diameter: 150 mm - cable stiffness: flexible without cable end Power circuit: bars 2 1...4 mm2 - cable stiffness: flexible without cable end - busbar cross section: 30 x 5 mm Control circuit: screw clamp terminals 1 1...4 mm2 - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm2 - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...2.5 mm2 - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...2.5 mm2 - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm2 - external diameter: 150 mm - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1...4 mm2 - cable stiffness: solid without cable end - busbar cross section: 30 x 5 mm |
| Tightening torque | Control circuit: 1.2 N.m Power circuit: 35 N.m |
| Auxiliary contact composition | Without |
| Mounting support | Plate |
| Standards | EN/IEC 60947-1 EN/IEC 60947-4-1 GB/T 14048.1 GB/T 14048.4 |
|---|---|
| Product certifications | CB Scheme CCC CE EAC |
| IP degree of protection | IP00 conforming to IEC 60529 |
| Permissible ambient air temperature around the device | -20...70 °C at Uc -60...80 °C storage -5...55 °C operation |
| Operating altitude | 3000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contactor open (1.5 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Vibrations contactor closed (5 Gn, 5...300 Hz) Shocks contactor closed (15 Gn for 11 ms) |
| Height | 375 mm |
| Width | 213 mm |
| Depth | 219 mm |
| Net weight | 9.1 kg |
| Part number | LC1E400M7 |
|---|---|
| Type designation | LC1E |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| Warranty (in months) | 18 |
|---|
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 26.000 cm |
| Package 1 Width | 24.000 cm |
| Package 1 Length | 32.000 cm |
| Package 1 Weight | 9.329 kg |
| Unit Type of Package 2 | S06 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 75.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 106.290 kg |
| Shipping weight | 0.98 kg |
| Ships from | Türkiye |
| Dispatch | 16 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 29 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of LC1E is 400 A.
The rated operational voltage of LC1E is 440 V AC.
The tariff (HS) code on file for LC1E is 85365080.
LC1E ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.