Part number
LC1D95BD
Model no
LC1D
1,376.77 SR In stock · 20 Dispatch Planned dispatch date. We aim to ship within 1 business day. Depending on warehouse workload it can take 2–3 business days. · From Türkiye

Schneider Electric LC1D95BD TeSys Deca 3-Pole 95A 60HP 480VAC Coil 24VDC Power Contactor

Rated current
95 A
Rated operational voltage
480 V AC
Motor power
45 kW
Poles
3P
EAN
3389110450576
Description

About the LC1D

The Schneider Electric LC1D95BD is a TeSys Deca series 3-pole power contactor rated at 95A and 60HP for 480VAC motor control applications. Designed for industrial environments, this open-style contactor features a 24VDC coil and is built to IEC standards, making the LC1D95BD a reliable choice for motor switching, power distribution, and automation control panels requiring robust AC-3 duty performance.

Certifications & Standards

  • IEC: Designed and tested in accordance with IEC international standards for low-voltage switchgear and controlgear, ensuring safety and performance compliance for global industrial applications.
Specification

Full specification

75 values · Last verified 29 Oct 2026

Main 10

Range TeSys
Range of Product TeSys Deca Advanced
Product or Component Type Contactor
Device short name LC1D
Contactor application Resistive load Motor control
Utilisation category AC-3 AC-3e AC-1 AC-4
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current 95 A (at <140 °F (60 °C)) at <= 440 V AC-3 for power circuit 125 A (at <140 °F (60 °C)) at <= 1000 V AC-1 for power circuit 95 A (at <140 °F (60 °C)) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage 24 V DC

Complementary 37

Motor power kW 25 kW at 220/230 V AC 50/60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 25 kW at 220/230 V AC 50/60 Hz (AC-3e) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 15 kW at 400 V AC 50/60 Hz (AC-4)
Maximum Horse Power Rating 7.5 hp at 120 V AC 60 Hz for 1 phase motors 15 hp at 230/240 V AC 60 Hz for 1 phase motors 30 hp at 200/208 V AC 60 Hz for 3 phase motors 30 hp at 230/240 V AC 60 Hz for 3 phase motors 60 hp at 460/480 V AC 60 Hz for 3 phase motors 60 hp at 575/600 V AC 60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit 125 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 1100 A at 440 V AC for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1100 A 104 °F (40 °C) - 1 s for power circuit 800 A 104 °F (40 °C) - 10 s for power circuit 400 A 104 °F (40 °C) - 1 min for power circuit 135 A 104 °F (40 °C) - 10 min for power circuit 140 A - 100 ms for signalling circuit 120 A - 500 ms for signalling circuit 100 A - 1 s for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole 12.5 W AC-1 7.2 W AC-3 7.2 W AC-3e
[Ui] rated insulation voltage Power circuit 1000 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV IEC 60947
Safety reliability level B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1 B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 10 Mcycles
Electrical durability 1.2 Mcycles 95 A AC-3 1.3 Mcycles 125 A AC-1 1.2 Mcycles 95 A AC-3e
Control circuit type DC standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.1...0.3 Uc (-40...158 °F (-40...70 °C)):drop-out DC 0.85...1.1 Uc (-40...131 °F (-40...55 °C)):operational DC 1...1.1 Uc (131...158 °F (55...70 °C)):operational DC
Inrush power in W 22 W 68 °F (20 °C))
Hold-in power consumption in W 22 W 68 °F (20 °C)
Operating time 95...130 ms closing 20...35 ms opening
Time constant 75 ms
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 0.002...0.004 in2 (1...2.5 mm2) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.004 in2 (1...2.5 mm2) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in2 (1...4 mm2) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in2 (1...4 mm2) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.006 in2 (1...4 mm2) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in2 (1...4 mm2) - cable stiffness: solid without cable end Power circuit: connector 1 0.006...0.08 in2 (4...50 mm2) - cable stiffness: flexible without cable end Power circuit: connector 2 0.006...0.04 in2 (4...25 mm2) - cable stiffness: flexible without cable end Power circuit: connector 1 0.006...0.08 in2 (4...50 mm2) - cable stiffness: flexible with cable end Power circuit: connector 2 0.006...0.02 in2 (4...16 mm2) - cable stiffness: flexible with cable end Power circuit: connector 1 0.006...0.08 in2 (4...50 mm2) - cable stiffness: solid without cable end Power circuit: connector 2 0.006...0.04 in2 (4...25 mm2) - cable stiffness: solid without cable end
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Mounting Support Rail Plate

Environment 14

Standards EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ IEC 60335-1:Clause 30.2
Product Certifications IECEE CB Scheme CCC EAC LROS (Lloyds register of shipping) RINA BV DNV-GL
IP degree of protection IP20 front face IEC 60529
Protective treatment THIEC 60068-2-30
Climatic withstand IACS E10 exposure to damp heat
Permissible ambient air temperature around the device -40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating
Operating altitude 0...9842.52 ft (0...3000 m)
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz) Shocks contactor open 8 Gn for 11 ms) Vibrations contactor closed 3 Gn, 5...300 Hz) Shocks contactor closed 10 Gn for 11 ms)
Height 5 in (127 mm)
Width 3.3 in (85 mm)
Depth 7.3 in (186 mm)
Net Weight 5.75 lb(US) (2.61 kg)
Show all 75 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number LC1D95BD
Type designation LC1D
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3389110450576

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin CZ
Shipping weight 2.61 kg
Ships from Türkiye
Dispatch 16 Nov
Stock In stock

Source: manufacturer data · Last verified: 29 Oct 2026

Documents

Documents for LC1D95BD

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CCC
  • EAC
  • CB Scheme
Quick answers

Questions about the LC1D

What is the rated current of LC1D?

The rated current of LC1D is 95 A.

Which supply voltage is LC1D rated for?

The rated operational voltage of LC1D is 480 V AC.

What motor power is LC1D rated for?

The rated motor power of LC1D is 45 kW.

What is the HS code of LC1D for customs?

The tariff (HS) code on file for LC1D is 85365080.

What is the EAN of LC1D?

The EAN (GTIN) of LC1D is 3389110450576.

Where does LC1D ship from, and how fast?

LC1D ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Schneider Electric Schneider TeSys Deca

Brand
Schneider Electric
Series
Schneider TeSys Deca
Series page →
Series

Other series in Contactors

1,376.77 SR In stock · 16 Nov
Quote

Get a Quote

LC1D

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LC1D95BD

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart