Part number
LC1D32BD
408.07 SR In stock · 50+ Dispatch Planned dispatch date. We aim to ship within 1 business day. Depending on warehouse workload it can take 2–3 business days. · From Türkiye

Schneider Electric LC1D32BD TeSys Deca 3-Pole 32A 480V AC 24VDC Coil 20HP Power Contactor

The Schneider Electric LC1D32BD is a 3-pole TeSys Deca Advanced contactor rated 32 A (AC-3) / 15 kW at 400 V, 20 hp at 480 V, with a 24 V DC coil and 1 NO + 1 NC auxiliary contacts.

Poles
3
AC-3 current (400 V)
32 A
Motor power (400 V)
15 kW
Motor power (480 V)
20 hp @ 460/480 V
Coil voltage
24 V DC
Auxiliary contacts
1 NO + 1 NC
EAN
3389110357257
Description

About the LC1D32BD

The Schneider Electric LC1D32BD is a TeSys Deca series 3-pole AC power contactor rated at 32A and 480V AC, delivering reliable motor switching performance for industrial applications up to 20HP. Designed for open-style panel mounting, this LC1D contactor features a 24V DC coil and an impressive 100 kA breaking capacity, making it a robust choice for demanding motor control and load-switching environments.

Applications & Use Cases

  • Motor Control Centers (MCC): Ideal for switching and controlling three-phase AC motors up to 20HP in MCC panels and industrial switchgear.
  • Pump & Fan Drives: Suitable for HVAC systems, water treatment plants, and industrial fan/pump control requiring reliable AC-3 switching duty.
  • Conveyor & Machine Tool Control: Handles repetitive on/off switching cycles in production lines, conveyor systems, and automated machinery.
  • OEM Equipment Integration: Compact open-style design makes LC1D32BD suitable for integration into OEM panels, motor starters, and custom control assemblies.
  • Building Automation & Process Control: Compatible with PLC and relay-based control systems using 24V DC control circuits, enabling seamless integration into modern automation architectures.

Applications (manufacturer): Resistive load, Motor control

Specification

Full specification

119 values · Last verified 03 Nov 2026

General 5

Series TeSys Deca Advanced
Contactor size / frame D32
Number of poles 3
Main contact configuration 3 NO
Utilisation categories AC-3 AC-3e AC-1 AC-4

Electrical 9

Rated operational current Ie, AC-3, 400 V 32 A
Rated motor power, AC-3, 400 V 15 kW
Motor power at other voltages, AC-3 7.5 kW @ 220/230 V · 15 kW @ 415/440 V · 18.5 kW @ 500 V · 18.5 kW @ 660/690 V
Rated operational current, AC-1 (60 °C) 50 A
Conventional free-air thermal current Ith 50 A
Rated motor power, AC-4, 400 V 7.5 kW
Max. rated operational voltage Ue 690 V
Rated insulation voltage Ui 690 V
Rated impulse withstand voltage Uimp 6 kV

Control circuit 4

Rated control supply voltage Uc 24 V
Coil type DC
Coil technology Built-in bidirectional peak limiting diode suppressor
Coil holding power 5.4 W | VA
Show all 54 specifications ↓ Show less ↑36 more values in Identification, Auxiliary contacts, Mechanical, Dimensions and weight, Environmental, North American ratings (UL/CSA), Certifications and standards, Logistics. 65 more as published by Schneider Electric are shown on request.

Identification 11

Part number LC1D32BD
Model code D32
Brand Schneider Electric
Series TeSys Deca Advanced
Family Contactors
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3389110357257
Catalogue number explained LC1 = 3-pole contactor; D = TeSys Deca Advanced range; 32 = 32 A AC-3 rating; BD = coil code (24 V DC)

Auxiliary contacts 4

Built-in auxiliary contacts, NO 1
Built-in auxiliary contacts, NC 1
Auxiliary contacts 1 NO + 1 NC
Mirror contact (IEC 60947-4-1 Annex F) Yes

Mechanical 2

Main circuit connection Screw terminal
Mounting 35 mm DIN rail, Panel (screw) mounting

Dimensions and weight 4

Width 45 mm
Height 85 mm
Depth 101 mm
Net weight 0.535 kg

Environmental 4

Ambient operating temperature -40 … 60 °C
Degree of protection IP20
Mechanical durability 30000000 cycles
Max. operating frequency, AC-3 3600 cycles/h

North American ratings (UL/CSA) 3

Motor rating (UL/CSA) 10 hp @ 200/208 V · 10 hp @ 230/240 V · 20 hp @ 460/480 V · 25 hp @ 575/600 V · 2 hp @ 115 V (1-ph) · 5 hp @ 230/240 V (1-ph)
Short-circuit current rating (SCCR) 100 kA
Max. operating voltage UL/CSA 600 V

Certifications and standards 2

Certifications CB Scheme, UL, CSA, CCC, UKCA, EAC, Marine
Conforming standards CSA C22.2 No 14, CSA C22.2 No 60947-4-1, EN 60947-4-1, EN 60947-5-1, IEC 60335-1, IEC 60335-2-40, IEC 60947-4-1, IEC 60947-5-1, UL 60335-2-40, UL 60947-4-1

Logistics 6

Package dimensions (L × W × H) 112 × 92 × 50 mm
Package weight 0.585 kg
Shipping weight 0.375 kg
Ships from Türkiye
Dispatch 16 Nov
Stock In stock
Additional manufacturer data 65 65 more values as published by Schneider Electric, shown on request.

Additional manufacturer data 65

Product or Component Type Contactor
Device short name LC1D
Compatibility code LC1D
Protective cover With
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 550 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 260 A 104 °F (40 °C) - 10 s for power circuit 430 A 104 °F (40 °C) - 1 s for power circuit 60 A 104 °F (40 °C) - 10 min for power circuit 138 A 104 °F (40 °C) - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2 mOhm - Ith 50 A 50 Hz for power circuit
Power dissipation per pole 2 W AC-3 5 W AC-1 2 W AC-3e
Overvoltage category III
Pollution degree 3
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Electrical durability 1.65 Mcycles 32 A AC-3 <= 440 V 1.4 Mcycles 50 A AC-1 <= 440 V 1.65 Mcycles 32 A AC-3e <= 440 V
Control circuit type DC standard
Control circuit voltage limits 0.1...0.25 Uc (-40...158 °F (-40...70 °C)):drop-out DC 0.7...1.25 Uc (-40...140 °F (-40...60 °C)):operational DC 1...1.25 Uc (140...158 °F (60...70 °C)):operational DC
Inrush power in W 5.4 W 68 °F (20 °C))
Operating time 63 ±15 % ms closing 20 ±20 % ms opening
Time constant 28 ms
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Protective treatment THIEC 60068-2-30
Climatic withstand IACS E10 exposure to damp heat IEC 60947-1 Annex Q category D exposure to damp heat
Operating altitude 0...9842.52 ft (0...3000 m)
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz) Vibrations contactor closed 4 Gn, 5...300 Hz) Shocks contactor closed 15 Gn for 11 ms) Shocks contactor open 8 Gn for 11 ms)
Category US1CTR121254
Discount Schedule CTR1
Returnability Yes
Unit Type of Package 1 PCE
Nbr. of units in pkg. 1
Unit Type of Package 2 S02
Number of Units in Package 2 15
Package 2 Height 5.906 in (15.000 cm)
Package 2 Width 11.811 in (30.000 cm)
Package 2 Length 15.748 in (40.000 cm)
Package 2 Weight 19.963 lb(US) (9.055 kg)
Unit Type of Package 3 P06
Number of Units in Package 3 240
Package 3 Height 29.528 in (75.000 cm)
Package 3 Width 23.622 in (60.000 cm)
Package 3 Length 31.496 in (80.000 cm)
Package 3 Weight 340.614 lb(US) (154.500 kg)
Total lifecycle Carbon footprint 45 kg CO2 eq.
Carbon footprint of the manufacturing phase [A1 to A3] 3 kg CO2 eq.
Carbon footprint of the distribution phase [A4] 0.2 kg CO2 eq.
Carbon footprint of the installation phase [A5] 0 kg CO2 eq.
Carbon footprint of the use phase [B2, B3, B4, B6] 40 kg CO2 eq.
Carbon footprint of the end-of-life phase [C1 to C4] 1 kg CO2 eq.
Environmental Disclosure Product Environmental Profile
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
SCIP Number 50ae7612-fd2e-41e4-a369-50d0dea6e592
California proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer and/or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
PVC free Yes
Repair No
Recyclability potential, in % 75
Circularity Profile End of Life Information
Take-back No
WEEE Label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

Source: manufacturer data · Last verified: 03 Nov 2026

Documents

Documents for LC1D32BD

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CB Scheme
  • UL
  • CSA
  • CCC
  • UKCA
  • EAC
  • Marine
  • CSA C22.2 No 14
  • CSA C22.2 No 60947-4-1
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60335-1
  • IEC 60335-2-40
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 60335-2-40
  • UL 60947-4-1
Quick answers

Questions about the LC1D32BD

What is the rated current of LC1D32BD?

The rated current of LC1D32BD is 32 A (AC-3, 400 V).

Which supply voltage is LC1D32BD rated for?

The rated operational voltage of LC1D32BD is 690 V AC.

What motor power is LC1D32BD rated for?

The rated motor power of LC1D32BD is 15 kW (AC-3, 400 V).

Which control voltage does LC1D32BD need?

The control voltage range of LC1D32BD is 24 V DC.

What is the EAN of LC1D32BD?

The EAN (GTIN) of LC1D32BD is 3389110357257.

Where does LC1D32BD ship from, and how fast?

LC1D32BD ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1 business day.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Schneider Electric TeSys Deca Advanced

Brand
Schneider Electric
Series
TeSys Deca Advanced
Series page →
Series

Other series in Contactors

408.07 SR In stock · 16 Nov
Quote

Get a Quote

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LC1D32BD

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart