ABB S200 vs S800: Standard vs High-Performance MCB
ABB S200 and S800 MCBs compared on current rating, breaking capacity, standards, and the point where a feeder outgrows S200 and needs S800.
The Schneider Electric EZ9F57232 Easy9 Pro is a 2-pole 32A miniature circuit breaker (MCB) rated at 6 kA breaking capacity, designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial distribution boards. Compliant with IEC EN 60898-1, the EZ9F57232 delivers dependable performance in space-constrained control panels and DIN rail installations.
| Range | Easy9 Pro |
|---|---|
| Device application | Distribution |
| Product or component type | Miniature circuit-breaker |
| Device short name | Easy9 Pro MCB |
| Poles description | 2P |
| Number of protected poles | 2 |
| [In] rated current | 32 A |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Suitability for isolation | Yes conforming to IEC/EN 60898-1 |
| Network frequency | 50/60 Hz |
|---|---|
| [Ue] rated operational voltage | 415 V AC 50/60 Hz |
| Magnetic tripping limit | 5...10 x In conforming to IEC/EN 60898-1 |
| Breaking capacity | 6000 A Icu at 415 V AC 50/60 Hz conforming to IEC/EN 60898-1 |
| [Ics] rated service breaking capacity | 6000 A 100 % conforming to IEC/EN 60898-1 - 415 V AC 50/60 Hz |
| Limitation class | 3 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to IEC/EN 60898-1 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to IEC/EN 60898-1 |
| Contact position indicator | Yes |
| Control type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top: pin type, Bottom: pin/fork type |
| 9 mm pitches | 4 |
| Height | 85 mm |
| Width | 36 mm |
| Depth | 77 mm |
| Net weight | 234 g |
| Colour | Grey (RAL 7035) |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Provision for padlocking | Yes |
| Connections - terminals | Tunnel type terminals (bottom) 1…25 mm² flexible, Tunnel type terminals (bottom) 1…35 mm² rigid |
| Tightening torque | 3.5 N.m |
| Standards | IEC/EN 60898-1 |
|---|---|
| Product certifications | TSE, CE |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC/EN 60947-2 |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Ambient air temperature for operation | -30…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Part number | EZ9F57232 |
|---|---|
| Type designation | Easy9 Pro MCB |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| Warranty (in months) | 18 |
|---|
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.500 cm |
| Package 1 Width | 3.600 cm |
| Package 1 Length | 8.500 cm |
| Package 1 Weight | 236.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 72 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 16.992 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 576 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 60.000 cm |
| Package 3 Weight | 130.848 kg |
| Shipping weight | 0.24 kg |
| Ships from | Türkiye |
| Dispatch | 16 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of Easy9 Pro MCB is 32 A.
The tariff (HS) code on file for Easy9 Pro MCB is 853620.
Easy9 Pro MCB ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
ABB S200 and S800 MCBs compared on current rating, breaking capacity, standards, and the point where a feeder outgrows S200 and needs S800.
A grounded, spec-by-spec comparison of Schneider Acti9 iC60, ABB S200 and Siemens 5SY miniature circuit breakers covering curve availability, breaking-capacity tiers, RCBO options and...