- Part number
- XPSUDN13AP
Description
About the XPSUDN13AP
About the XPSUDN13AP
The Schneider Electric XPSUDN13AP is a Preventa XPSU universal safety relay module combining the function of six XPSUAF modules in one device, with 6 safety inputs and 3 NO + 1 NC safety outputs. Powered at 24 V AC/DC, it monitors emergency stop, guard switch, magnetic switch, proximity sensor, RFID switch or light-curtain circuits, reaching Category 4 / PLe per ISO 13849-1 and SIL 3 per IEC 61508.
Certifications & Standards
- TÜV
- cULus
- IEC 60947-5-1
- IEC 61508
- ISO 13849-1
- IEC 62061
Selection Notes
Choose the XPSUDN13AP when a machine has six independent safety circuits (E-stops, guard switches, light curtains) that would otherwise need six separate XPSUAF13AP modules — it consolidates them into one 45 mm wide device with 3 NO + 1 NC outputs covering the combined safety chain. The 24 V AC/DC supply matches the XPSUAF13AP and XPSUS12AP for consistent voltage selection across a control panel. Use the 48-240 V XPSUDN33AP instead on panels running a higher universal control voltage.
Specification
Full specification
Main 10
| Range of product | Harmony Safety Automation |
|---|---|
| Product or component type | Safety module |
| Safety module name | XPSUDN |
| Safety module application | Monitoring antivalent contacts, For emergency stop, guard and light curtain monitoring |
| Function of module | Emergency stop button with 2 NC contacts, Guard monitoring with 1 or 2 limit switches, Monitoring 2 PNP sensors, Magnetic switch monitoring, Light curtain monitoring, RFID switch, Monitoring of electro-sensitive protection equipment (ESPE), Proximity sensor monitoring |
| Safety level | Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1, Can reach SILCL 3 for normally open relay contact conforming to IEC 62061, Can reach SIL 3 for normally open relay contact conforming to IEC 61508, Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1, Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061, Can reach SIL 1 for normally closed relay contact conforming to IEC 61508 |
| Safety reliability data | MTTFd > 30 years conforming to ISO 13849-1, Dcavg >= 99 % conforming to ISO 13849-1, PFHd = 0.88E-09 conforming to ISO 13849-1, HFT = 1 conforming to IEC 62061, PFHd = 0.88E-09 conforming to IEC 62061, SFF > 99% conforming to IEC 62061, HFT = 1 conforming to IEC 61508-1, PFHd = 0.88E-09 conforming to IEC 61508-1, SFF > 99% conforming to IEC 61508-1, Type = B conforming to IEC 61508-1 |
| Electrical circuit type | NC pair, PNP pair, Antivalent pair, OSSD pair |
| Connections - terminals | Removable screw terminal block, 0.2...2.5 mm² solid or flexible, Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor, Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor, Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel, Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| [Us] rated supply voltage | 24 V AC - 15...10 %, 24 V DC - 20...20 % |
Complementary 25
| Synchronisation time between inputs | 0.5 s, 2 s, 2.2 s, 4 s |
|---|---|
| Type of start | Automatic/manual/monitored |
| Power consumption in W | 4.5 W 24 V DC |
| Power consumption in VA | 10.5 VA 24 V AC 50/60 Hz |
| Input protection type | Internal, electronic |
| safety outputs | 3 NO + 1 NC |
| safety inputs | 6 safety input 24 V DC 5 mA |
| maximum wire resistance | 500 Ohm |
| Input compatibility | Normally closed circuit conforming to ISO 14119, XC limit switch conforming to ISO 14119, Mechanical contact conforming to ISO 14119, Normally closed circuit conforming to ISO 13850, Antivalent pair conforming to ISO 14119, OSSD pair conforming to IEC 61496-1-2, 3-wire proximity sensors PNP |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact, 3 A AC-15 for normally open relay contact, 5 A DC-1 for normally open relay contact, 3 A DC-13 for normally open relay contact, 3 A AC-1 for normally closed relay contact, 1 A AC-15 for normally closed relay contact, 3 A DC-1 for normally closed relay contact, 1 A DC-13 for normally closed relay contact |
| control outputs | 7 on/off configurable pulsed output |
| Input/output type | Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related |
| [Ith] conventional free air thermal current | 16 A |
| Associated fuse rating | 10 A gG for NO relay output circuit conforming to IEC 60947-1, 4 A gG for NC relay output circuit conforming to IEC 60947-1 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 12 V for relay output |
| Maximum response time on input open | 20 ms |
| [Ui] rated insulation voltage | 250 V (pollution degree 2) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category II conforming to IEC 60947-1 |
| Local signalling | LED (green) for power ON, LED (red) for error, LED (yellow) for start, LED (yellow) for safety status, LED (yellow) for safety input S12, LED (yellow) for safety input S13, LED (yellow) for safety input S22, LED (yellow) for safety input S23, LED (yellow) for safety input S32, LED (yellow) for safety input S33, LED (yellow) for safety input S42, LED (yellow) for safety input S43, LED (yellow) for safety input S52, LED (yellow) for safety input S53, LED (yellow) for safety input S62, LED (yellow) for safety input S73 |
| Mounting support | 35 mm symmetrical DIN rail |
| Depth | 120 mm |
| Height | 100 mm |
| Width | 45 mm |
| Net weight | 0.350 kg |
Environment 6
| Standards | IEC 60947-5-1, IEC 61508-1 functional safety standard, IEC 61508-2 functional safety standard, IEC 61508-3 functional safety standard, IEC 61508-4 functional safety standard, IEC 61508-5 functional safety standard, IEC 61508-6 functional safety standard, IEC 61508-7 functional safety standard, ISO 13849-1 functional safety standard, IEC 62061 functional safety standard |
|---|---|
| Product certifications | TÜV, cULus |
| IP degree of protection | IP20 (terminals) conforming to IEC 60947-1, IP40 (housing) conforming to IEC 60947-1, IP54 (mounting area) conforming to IEC 60947-1 |
| Ambient air temperature for operation | -25…50 °C at 24 V AC, -25…55 °C at 24 V DC |
| Ambient air temperature for storage | -25…85 °C |
| Relative humidity | 5…95 % non-condensing |
Show all 64 specifications ↓ Show less ↑23 more values in Identification, Contractual warranty, Logistics.
Identification 6
| Part number | XPSUDN13AP |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
Contractual warranty 1
| Warranty (in months) | 18 |
|---|
Logistics 16
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.500 cm |
| Package 1 Width | 15.500 cm |
| Package 1 Length | 13.500 cm |
| Package 1 Weight | 416.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.217 kg |
| Shipping weight | 0.35 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
Documents
Documents for XPSUDN13AP
No documents are on file for this part yet.
Ask us for the datasheet
Certifications
Certifications and standards
- cULus
- IEC 60947-5-1
- IEC 61508-1 functional safety standard
- IEC 61508-2 functional safety standard
- IEC 61508-3 functional safety standard
- IEC 61508-4 functional safety standard
- IEC 61508-5 functional safety standard
- IEC 61508-6 functional safety standard
- IEC 61508-7 functional safety standard
- ISO 13849-1 functional safety standard
- IEC 62061 functional safety standard
Quick answers
Questions about the XPSUDN13AP
What is the rated current of XPSUDN13AP?
The rated current of XPSUDN13AP is 16 A.
Which supply voltage is XPSUDN13AP rated for?
The rated operational voltage of XPSUDN13AP is 24–DC V DC.
What is the HS code of XPSUDN13AP for customs?
The tariff (HS) code on file for XPSUDN13AP is 853641.
Where does XPSUDN13AP ship from, and how fast?
XPSUDN13AP ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Reviews
Customer reviews
Series
Schneider Electric Harmony Safety Automation
- Brand
- Schneider Electric
- Series
- Harmony Safety Automation