The Schneider Electric XPSMCMCO0000CO is a Modicon MCM non-safe communication module that adds one CANopen port, via a male Sub-D 9 connector, to an XPSMCM safety controller for remote diagnostics. It connects over the backplane expansion connector and cannot operate stand-alone, reporting controller status to a CANopen network at rates from 10 kbit/s to 1 Mbit/s without an additional gateway.
The XPSMCMCO0000CO is a non-safe diagnostic module: it reports the connected XPSMCM safety controller's status over CANopen for remote monitoring but carries none of the safety function itself, so it expands an existing Modicon MCM safety controller CPU and cannot run stand-alone. Choose it over the EtherCAT, EtherNet/IP or Modbus TCP/IP diagnostic variants when the plant's existing fieldbus is CANopen, or choose the RS485 safe communication module instead when the link needs to carry safe communication rather than non-safe diagnostics.
The XPSMCMCO0000CO fits cells where a plant-wide CANopen SCADA or PLC network already polls other field devices, letting the same network pick up the safety controller's run/error status alongside drive and I/O diagnostics instead of running a separate monitoring cable back to the control room. The module relays status only and plays no part in the controller's own safety decision.
| Range of Product | Modicon MCM |
|---|---|
| Product or Component Type | Non-safe communication module |
| Device short name | XPSMCM |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Power dissipation in W | 3 W |
|---|---|
| Quality labels | CE |
| Range Compatibility | Preventa XPSMCM |
| Connector type | male SUB-D 9 |
| Number of port | 1 |
| Method of access | Server |
| Transmission rate | 10 kbit/s, 20 kbit/s, 50 kbit/s, 100 kbit/s, 125 kbit/s, 250 kbit/s, 500 kbit/s, 800 kbit/s, 1 Mbit/s, Autodetected |
| Communication Port Protocol | CANopen |
| Current Consumption | 0.125 mA |
| Maximum cable distance between devices | 8202.10 ft (2500 m), 3280.8 ft (1000 m), 2460.6 ft (750 m), 1640.4 ft (500 m), 820.2 ft (250 m), 328.08 ft (100 m), 164.04 ft (50 m), 82.02 ft (25 m) |
| Local signalling | LED green PWR power ON, LED green RUN operating, LED red E IN internal error, LED red E EX external error, LED green/red OP operating, LED green/red ERR communication error |
| Connections - terminals | 2 captive screw clamp terminals, removable terminal block |
| Cable cross section | 0.0003…0.002 in² (0.2…1.5 mm²) - 24 AWG...16 AWG flexible without cable end, 0.0003…0.004 in² (0.2…2.5 mm²) - 24 AWG...14 AWG flexible without cable end, 0.0004…0.002 in² (0.25…1 mm²) - 23 AWG...18 AWG flexible with cable end, without bezel, 0.0004…0.004 in² (0.25…2.5 mm²) - 23 AWG...14 AWG flexible with cable end, with bezel, 0.0004…0.004 in² (0.25…2.5 mm²) - 23 AWG...14 AWG flexible with cable end, without bezel, 0.0008…0.002 in² (0.5…1.5 mm²) - 20 AWG...16 AWG flexible with cable end, with double bezel, 0.0003…0.002 in² (0.2…1 mm²) - 24 AWG...18 AWG solid without cable end, 0.0003…0.004 in² (0.2…2.5 mm²) - 24 AWG...14 AWG solid without cable end |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Width | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Depth | 4.5 in (114.5 mm) |
| Net Weight | 0.7 lb(US) (0.3 kg) |
| Product Certifications | cULus, RCM, TÜV |
|---|---|
| IP Degree of Protection | IP20 |
| Ambient Air Temperature for Operation | 14…131 °F (-10…55 °C) |
| Ambient Air Temperature for Storage | -4…185 °F (-20…85 °C) |
| Relative humidity | 10…95 % |
| Pollution degree | 2 |
| Insulation | 250 V AC between power supply and housing IEC 61800-5-1 |
| Overvoltage category | II |
| Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2, Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2, Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3, Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3 |
| Vibration resistance | +/-0.35 mm (f= 10…55 Hz) conforming to IEC 61496-1 |
| Shock resistance | 10 gn 16 ms) 1000 shocks on each axis IEC 61496-1 |
| Operating altitude | 6561.68 ft (2000 m) |
| Service Life | 20 year(s) |
| Part number | XPSMCMCO0000CO |
|---|---|
| Type designation | XPSMCM |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606480748349 |
| Warranty (in months) | 18 |
|---|
| Country of origin | IT |
|---|---|
| Shipping weight | 0.3 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of XPSMCM is 24 V DC.
The tariff (HS) code on file for XPSMCM is 853710.
The EAN (GTIN) of XPSMCM is 3606480748349.
XPSMCM ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.