- Part number
- XALK188E
- Model no
- XALK
Description
About the XALK
About the XALK
The Schneider Electric XALK188E is a complete Harmony XALK control station for emergency stop and emergency switching off, built around an unmarked 40 mm red mushroom-head push button with key release (key number 455), wired 1NO + 1NC. The yellow-lidded polycarbonate housing is rated IP66/IP67/IP69/IP69K for washdown-exposed emergency stop points.
Certifications & Standards
- IEC 60947-5-1
- IEC 60947-5-4
- IEC 60947-5-5
- UL 508
- CSA C22.2 No 14
- ISO 13850
- IEC 60204-1
Selection Notes
The added 1NO contact lets this key-release station feed a status signal back to a controller while the 1NC breaks the safety circuit, the same logic that separates the turn-to-release XALK178E from the base XALK178. Where only a safety 1NC is needed with key release, the XALK188 covers it.
Specification
Full specification
Main 13
| Range of product | Harmony XALK |
|---|---|
| Product or component type | Complete control station |
| Device short name | XALK |
| Product destination | For XB5 Ø 22 mm control and signalling units |
| Control station application | Emergency switching off function, Emergency stop function |
| Colour of base of enclosure | Light grey (RAL 7035) |
| Colour of cover | Yellow (RAL 1021) |
| Material | Polycarbonate |
| Operator profile | 1 mushroom head push-button |
| Operators description | Red unmarked 1 NO + 1 NC |
| Reset | Key release |
| Control station composition | 1 mushroom head Ø 40 mm push-button, red 1 NO + 1 NC unmarked marking |
| Contact operation | Slow-break |
Complementary 35
| AC control voltage 50 HZ | 120…600 V |
|---|---|
| Cable entry | 1 knock-out for cable entry 0…14 mm, 2 knock-outs for Pg 13 cable gland and ISO M20 0…12 mm |
| AC control voltage 60 HZ | 120…600 V |
| Net weight | 0.188 kg |
| DC control voltage | 125…600 V |
| Resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m |
| Number of command positions | 1 |
| Number of indicator lights | 0 |
| Key number | 455 |
| Number of push buttons | 0 |
| Positive opening | With conforming to IEC 60947-5-1 appendix K |
| Operating travel | 1.5 mm (NC changing electrical state), 2.6 mm (NO changing electrical state), 4.3 mm (total travel) |
| Operating force | 44 N NC + NO changing electrical state |
| Number of selector switches | 0 |
| Mechanical durability | 300000 cycles |
| Connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1, Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1 |
| Number of key switches | 0 |
| Tightening torque | 0.8…1.2 N.m conforming to IEC 60947-1 |
| Shape of screw head | Cross compatible with Philips no 1 screwdriver, Cross compatible with pozidriv No 1 screwdriver, Slotted compatible with flat Ø 4 mm screwdriver, Slotted compatible with flat Ø 5.5 mm screwdriver |
| Contacts material | Silver alloy (Ag/Ni) |
| Short-circuit protection | 10 A cartridge fuse type gG conforming to IEC 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A conforming to IEC 60947-5-1 |
| Number of mushroom-shaped push-buttons | 1 |
| [Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| [Ie] rated operational current | 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1, 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1, 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1, 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1, 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1, 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1 |
| Electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
| Emergency power off | No |
| Electrical reliability | Λ < 10exp(-6) at 5 V, 1 mA conforming to IEC 60947-5-4, Λ < 10exp(-8) at 17 V, 5 mA conforming to IEC 60947-5-4 |
| Number of contacts as normally closed contact | 1 |
| Number of contacts as normally open contact | 1 |
| Number of contacts as change-over contact | 0 |
| Housing material | Plastic |
| Housing colour | Yellow |
| colour of cover | Yellow |
Environment 10
| Protective treatment | TH |
|---|---|
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -40…70 °C |
| Overvoltage category | Class II conforming to IEC 60536 |
| IP degree of protection | IP66 conforming to IEC 60529, IP67, IP69, IP69K |
| NEMA degree of protection | NEMA 13, NEMA 4X |
| IK degree of protection | IK03 conforming to IEC 62262 |
| Standards | UL 508, IEC 60204-1, CSA C22.2 No 14, IEC 60947-5-1, JIS C 4520, IEC 60947-5-4, IEC 60364-5-53, ISO 13850, IEC 60947-1, IEC 60947-5-5 |
| Vibration resistance | 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27, 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
Show all 82 specifications ↓ Show less ↑24 more values in Identification, Contractual warranty, Logistics.
Identification 7
| Part number | XALK188E |
|---|---|
| Type designation | XALK |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
Contractual warranty 1
| Warranty (in months) | 18 |
|---|
Logistics 16
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.7 cm |
| Package 1 Width | 7.0 cm |
| Package 1 Length | 7.0 cm |
| Package 1 Weight | 195.0 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 8.295 kg |
| Shipping weight | 0.188 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
Documents
Documents for XALK188E
No documents are on file for this part yet.
Ask us for the datasheet
Certifications
Certifications and standards
- UL 508
- IEC 60204-1
- CSA C22.2 No 14
- IEC 60947-5-1
- JIS C 4520
- IEC 60947-5-4
- IEC 60364-5-53
- ISO 13850
- IEC 60947-1
- IEC 60947-5-5
Quick answers
Questions about the XALK
What is the HS code of XALK for customs?
The tariff (HS) code on file for XALK is 853650.
Where does XALK ship from, and how fast?
XALK ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Reviews
Customer reviews
Series
Schneider Electric Harmony XALK
- Brand
- Schneider Electric
- Series
- Harmony XALK