- Part number
- XALD102
- Model no
- XALD
Description
About the XALD
About the XALD
The Schneider Electric XALD102 is a Harmony XALD complete control station with 1 green flush push button marked 'I', spring return, wired 1 NO for a start function. Its dark grey polycarbonate enclosure is rated IP66/IP67/IP69/IP69K and uses screw-clamp terminals rated 10 A.
Certifications & Standards
- IEC 60947-5-4
- IEC 60947-5-1
- JIS C8201-5-1
- UL 508
- IEC 60947-5-5
- IEC 60947-1
- CSA C22.2 No 14
- JIS C8201-1
Selection Notes
The XALD102 provides a single green 1 NO start pushbutton marked 'I' directly on the button cap; choose the XALD103 instead when the legend should read 'START', or the XALD112 for a red 1 NC stop function.
Specification
Full specification
Main 13
| Range of product | Harmony XALD |
|---|---|
| Product or component type | Complete control station |
| Device short name | XALD |
| Product destination | For XB5 Ø 22 mm control and signalling units |
| Control station application | Start function |
| Colour of base of enclosure | Light grey (RAL 7035) |
| Colour of cover | Dark grey (RAL 7016) |
| Material | Polycarbonate |
| Operator profile | 1 flush push-button |
| Operators description | Green ''I'' 1 NO |
| Control station composition | 1 flush push-button, green 1 NO I marking |
| Marking location | Marking on push-button |
| Contact operation | Slow-break |
Complementary 35
| AC control voltage 50 HZ | 120…600 V |
|---|---|
| Cable entry | 1 knock-out for cable entry, clamping capacity: 14 mm, 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm |
| AC control voltage 60 HZ | 120…600 V |
| Net weight | 0.135 kg |
| DC control voltage | 125…600 V |
| Resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m |
| Number of command positions | 1 |
| Number of indicator lights | 0 |
| Colour of marking | White marking when green, red or black caps, Black marking when white caps |
| Number of push buttons | 1 |
| Positive opening | Without |
| Operating travel | 2.6 mm (NO changing electrical state), 4.3 mm (total travel) |
| Operating force | 3.8 N NO changing electrical state |
| Mechanical durability | 10000000 cycles |
| Number of selector switches | 0 |
| Connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1, Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1 |
| Tightening torque | 0.8…1.2 N.m conforming to IEC 60947-1 |
| Number of key switches | 0 |
| Shape of screw head | Cross compatible with Philips no 1 screwdriver, Cross compatible with pozidriv No 1 screwdriver, Slotted compatible with flat Ø 4 mm screwdriver, Slotted compatible with flat Ø 5.5 mm screwdriver |
| Contacts material | Silver alloy (Ag/Ni) |
| Short-circuit protection | 10 A cartridge fuse type gG conforming to IEC 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A conforming to IEC 60947-5-1 |
| [Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to IEC 60947-1 |
| Number of mushroom-shaped push-buttons | 0 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| [Ie] rated operational current | 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1, 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1, 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1, 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1, 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1, 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1 |
| Electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
| Electrical reliability | Λ < 10exp(-6) at 5 V and 1 mA conforming to IEC 60947-5-4, Λ < 10exp(-8) at 17 V and 5 mA conforming to IEC 60947-5-4 |
| Emergency power off | No |
| Number of contacts as normally closed contact | 0 |
| Number of contacts as normally open contact | 1 |
| Number of contacts as change-over contact | 0 |
| Housing material | Plastic |
| Housing colour | Grey |
| colour of cover | Dark grey |
Environment 10
| Protective treatment | TH |
|---|---|
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -40…70 °C |
| Overvoltage category | Class II conforming to IEC 60536 |
| IP degree of protection | IP66 conforming to IEC 60529, IP67, IP69, IP69K |
| NEMA degree of protection | NEMA 13, NEMA 4X |
| IK degree of protection | IK03 conforming to IEC 62262 |
| Standards | IEC 60947-5-4, IEC 60947-5-1, JIS C8201-5-1, UL 508, IEC 60947-5-5, IEC 60947-1, CSA C22.2 No 14, JIS C8201-1 |
| Vibration resistance | 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27, 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
Show all 88 specifications ↓ Show less ↑30 more values in Identification, Contractual warranty, Logistics.
Identification 7
| Part number | XALD102 |
|---|---|
| Type designation | XALD |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
Contractual warranty 1
| Warranty (in months) | 18 |
|---|
Logistics 22
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.000 cm |
| Package 1 Width | 7.000 cm |
| Package 1 Length | 10.000 cm |
| Package 1 Weight | 137.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 5.871 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 320 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 60.000 cm |
| Package 3 Weight | 54.968 kg |
| Shipping weight | 0.135 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
Documents
Documents for XALD102
No documents are on file for this part yet.
Ask us for the datasheet
Certifications
Certifications and standards
- IEC 60947-5-4
- IEC 60947-5-1
- JIS C8201-5-1
- UL 508
- IEC 60947-5-5
- IEC 60947-1
- CSA C22.2 No 14
- JIS C8201-1
Quick answers
Questions about the XALD
What is the HS code of XALD for customs?
The tariff (HS) code on file for XALD is 853650.
Where does XALD ship from, and how fast?
XALD ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Reviews
Customer reviews
Series
Schneider Electric Harmony XALD
- Brand
- Schneider Electric
- Series
- Harmony XALD