Schneider Electric VPL12N VarPlus Logic Power Factor Controller 12 Steps Modbus Power Factor Controller

VarPlus Logic power factor controller, 12 steps, 90-550 V AC, Modbus RS485, backlit LCD.

Rated operational voltage
90–550 V AC
EAN
3606480800115
Description

About the VPL12

The Schneider Electric VPL12N is a VarPlus Logic power factor controller with 12 step output contacts for automatic power factor correction equipment. It measures voltage and current to regulate capacitor banks across a 90-550 V AC supply range, communicates over Modbus RS485, and displays readings on a backlit LCD. Automatic step detection and manual or automatic operating modes let one controller manage a twelve-stage capacitor bank.

Certifications & Standards

  • EAC
  • NRTL
  • cNRTL
  • CE
  • IEC 61000-6-2
  • EN 61010-1
  • IEC 61000-6-4
  • IEC 61326-1
  • UL 61010-1

Selection Notes

Twelve step output contacts give finer correction resolution than the 6-step controller in the same VarPlus Logic family, so pick this version when the capacitor bank has more than six switchable stages; a 6-step controller on a larger bank would force coarser steps and raise the risk of overcompensation. Both controllers share the same 90-550 V AC measurement range, Modbus RS485 port, and automatic step-size detection, so the choice comes down to the number of physical steps in the bank, not the electrical rating.

Specification

Full specification

60 values · Last verified 30 Oct 2026

Main 4

Range PowerLogic
Product name PowerLogic PFC Controller
Product or Component Type Power factor controller
Device short name VPL12

Complementary 36

Number of step output contacts 12
[Us] rated supply voltage 90...550 V AC, <= 999 kV AC with external VT
Measurement current 0…5 A
Measurement voltage 90…550 V AC 50/60 Hz
Operating Mode Manual or automatic
Number of quadrant operation for generator application 4
Device connection Communication Modbus RS485
Input function Switch 1 x dry contact
Colour code Front dark grey RAL 7016
Display Type Backlit LCD
Display size 56 x 25 mm
Function Available Manual programming, Automatic initialisation, Automatic detection, Advanced programming (expert), Any step sequence
Metering type Power factor and displacement PF (signed, four quadrant), Total current harmonic distortion THD (I), Power factor average over lifetime, Temperature maximum, Phase current I1, I2, I3 RMS on load, Active power P, P1, P2, P3 on load, Reactive power Q, Q1, Q2, Q3 on load, Apparent power S, S1, S2, S3 on load, Voltage U21, U32, U13, V1, V2, V3 on load
Type of Measurement Capacitor current overload Irms/I1, Individual voltage harmonic, Power factor, Operating time, Cos φ, Ambient temperature inside the cubicle, Tan φ
Information Displayed Number of switching cycles per step, Individual step size in kVAr, Remaining step capacity in %
Type of alarms Step power loss < 75 %)message and alarm contact + step blocked, Step faultymessage and alarm contact + step blocked, High current > 6 A CT)message and alarm contact, Hunting (unstable regulation)message and alarm contact + step blocked, Low current < 15 mA CT)message and alarm contact, Overcompensationmessage and alarm contact, Capacitor current overload (Irms/I1) > 130 % I1)message and alarm contact + step switched off, Over Temperature 50 °C)message and alarm contact + step switched off, Over Temperature 30 °C)fan switch, Over Voltage +/- 10 %)message and alarm contact + control stopped, Total harmonic distortion > 7 %)message and alarm contact + step switched off
Data recording 5 alarms
Operational Hours alarm 100000 h without maintenance
Operational counter alarm 65000 cycles without maintenance
Input type Phase to phase, Phase to neutral, Insensitive to CT polarity, Insensitive to phase rotation polarity, Current input CT...X/5 A and X/1 A
Output type Control relay 0.2 A 110 V DC, Control relay 1 A 48 V DC, Control relay 2 A 400 V AC 50/60 Hz, Control relay 1 A 24 V DC, Control relay 5 A 250 V AC 50/60 Hz, Control relay 5 A 120 V AC 50/60 Hz, Fan 5 A 250 V AC 50/60 Hz, Fan 1 A 48 V DC, Alarm relay 5 A 250 V AC 50/60 Hz, Alarm relay 1 A 48 V DC
Maximum at the common terminal 10 A
Settings operating mode Automatic, Manual
Type of setting Choice of stepping programs auto, Choice of stepping programs LIFO, Choice of stepping programs linear, Delay between 2 successive switch on the same step 5...1200 s, Step configuration programming auto, Step configuration programming off, Step configuration programming fixed, Target cos phi 0.7 inductive...0.7 capacitive, Target cos phi dual cos φ
Measurement accuracy Voltage +/- 1 %, Current +/- 1 %, Frequency +/- 1 %, Energy (P,Q,S) +/- 2 %, Cos φ +/- 2 %, Total voltage harmonic distortion THD (U) +/- 2 %, Individual voltage harmonic +/- 3 %, Temperature +/- 3 °C
Time delay range 1...6500 s on reconnection), 1...6500 s on response)
Provided Equipment User Manual
Mounting Mode Flush-mounted
Mounting support Panel 0.04…0.1 in (1…3 mm)
Mounting Location In cabinet
Cut-out dimensions 138 x 138 mm
Height 5.7 in (144 mm)
Width 5.7 in (144 mm)
Depth 2.3 in (58 mm)
Net Weight 1.3 lb(US) (0.6 kg)
Compatibility code VPL 12

Environment 6

Standards IEC 61000-6-4, UL 61010-1, EN 61010-1, IEC 61000-6-2, IEC 61326-1
Product Certifications EAC, NRTL, cNRTL, CE
IP degree of protection Front face IP41, Rear face IP20
Operating altitude <= 6561.68 ft (2000 m)
Ambient Air Temperature for Operation -4…140 °F (-20…60 °C)
Ambient Air Temperature for Storage -40…185 °F (-40…85 °C)
Show all 60 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number VPL12N
Type designation VPL12
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3606480800115

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin DE
Shipping weight 0.6 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for VPL12N

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CE
  • EAC
  • IEC 61000-6-4
  • UL 61010-1
  • EN 61010-1
  • IEC 61000-6-2
  • IEC 61326-1
Quick answers

Questions about the VPL12

Which supply voltage is VPL12 rated for?

The rated operational voltage of VPL12 is 90–550 V AC.

What is the HS code of VPL12 for customs?

The tariff (HS) code on file for VPL12 is 853710.

What is the EAN of VPL12?

The EAN (GTIN) of VPL12 is 3606480800115.

Where does VPL12 ship from, and how fast?

VPL12 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for power factor correction

All guides for power factor correction
Reviews

Customer reviews

1,127.28 SR On request
Get a Quote
Quote

Get a Quote

VPL12

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · VPL12N

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart