IEC 60947-4-1 Standards for Contactors and Motor Starters Explained
Master AC-3 rating selection under IEC 60947-4-1 for contactors and motor starters, including utilization categories and coordination types. Shop at Stoklink.
The Schneider Electric TPRAN2X1 is a TeSys Island analog IO module with 2 configurable analog inputs and 1 configurable analog output, supplied with 24 V DC from the bus coupler. It connects to a TPRBC bus coupler to enable advanced control functions (TeSys avatars) within a TeSys island configuration.
Add the TPRAN2X1 to a TeSys island configuration when the application needs analog measurement or control beyond the motor-starter modules themselves, such as process temperature or 4-20 mA sensor inputs; it is only operational when connected to a TPRBC bus coupler.
| Range | TeSys |
|---|---|
| Product name | TeSys island |
| Device short name | TPRAN |
| Product or Component Type | Analog IO module |
| Device presentation | IO module providing 2 analog inputs and 1 analog output, Enabling advanced control functions in a TeSys island system, Operational only when connected to a bus coupler TPRBC |
| Function of module | Measurement of voltage, current or temperature on 2 configurable analog inputs, Driving voltage or current source on 1 configurable analog output |
| Product compatibility | TPRBC bus coupler |
| Analogue input number | 2 isolated with common point |
| Analogue input type | Current 4...20 mA, Current 0...20 mA, Voltage 0...10 V, Voltage - 10...10 V, Temperature probe - 60...180 °C Ni 100, Temperature probe - 60...180 °C Ni 1000, Temperature probe -200...+850 °C Pt 100, Temperature probe - 200...600 °C Pt 1000, Thermocouple - 200...1000 °C thermocouple J, Thermocouple - 200...1300 °C thermocouple K, Thermocouple 0...1760 °C thermocouple R, Thermocouple 0...1760 °C thermocouple S, Thermocouple 0...1820 °C thermocouple B, Thermocouple - 200...400 °C thermocouple T, Thermocouple - 200...1300 °C thermocouple N, Thermocouple - 200...800 °C thermocouple E, Thermocouple 0...2315 °C thermocouple C |
| Measurement accuracy | +/- 0.1 % of full scale voltage 77 °F (25 °C), +/- 0.1 % of full scale current 77 °F (25 °C), +/- 0.1 % of full scale temperature probe 77 °F (25 °C), +/- 0.1 % of full scale in positive temperature range thermocouple 77 °F (25 °C), +/- 0.4 % of full scale in negative temperature range thermocouple 77 °F (25 °C) |
| Analogue input resolution | 15 bits + sign full scale |
| Input impedance | <= 50 Ohm current, >= 1 MOhm voltage, >= 1 MOhm thermocouple, >= 1 MOhm temperature probe |
| Analogue output number | 1 isolated |
| Analogue output type | Current 4...20 mA, Current 0...20 mA, Voltage 0...10 V, Voltage - 10...10 V |
| Analogue output resolution | 12 bits, 4...20 mA full scale, 12 bits, 0...20 mA full scale, 12 bits, 0...10 V full scale, 11 bits + sign, - 10...10 V full scale |
| Type of cable | Twisted shielded pairs cable <98.4 ft (30 m) input/output |
| Local signalling | 1 LED (green/red) for DS (device status) |
| [Us] rated supply voltage | 24 V DC supplied by the bus coupler |
|---|---|
| Current consumption | 160 mA |
| Power dissipation in W | 0.5 W maximum |
| [Uimp] rated impulse withstand voltage | 0.5 kV IEC 61010-1 |
| Standards | IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201 |
| Product certifications | CSA, UL, EAC (pending) |
| Mounting mode | Horizontal and vertical 35 mm symmetrical rail) |
| Connections - terminals | Input/output circuit removable spring terminal block 8 0.0003…0.004 in² (0.2…2.5 mm²) 24 AWG...14 AWG)rigid, Input/output circuit removable spring terminal block 8 0.0003…0.004 in² (0.2…2.5 mm²) 24 AWG...14 AWG)flexible without cable end, Input/output circuit removable spring terminal block 8 0.0004…0.004 in² (0.25…2.5 mm²) 22 AWG...14 AWG)flexible with cable end |
| Width | 1.0 in (25 mm) |
| Height | 4.6 in (118 mm) |
| Depth | 4.5 in (114 mm) |
| Net Weight | 0.379 lb(US) (0.172 kg) |
| Ambient air temperature for storage | -13…158 °F (-25…70 °C) |
|---|---|
| Ambient Air Temperature for Operation | 14…140 °F (-10…60 °C) |
| Relative Humidity | 5…95 % |
| Operating altitude | 0...6561.68 ft (0...2000 m) without derating |
| IP degree of protection | IP20 |
| Pollution degree | 2 |
| Protective treatment | TC |
| Fire resistance | 1760 °F (960 °C) UL 94 |
| Shock resistance | 15 gn 11 ms) IEC 60068-2-27 |
| Vibration resistance | 1.5 mm peak to peak 3…13 Hz) IEC 60068-2-6, 1 gn 13…200 Hz) IEC 60068-2-6 |
| Electromagnetic compatibility | Electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2, Radiated RF fields, level 3, 10 V/m, conforming to EN/IEC 61000-4-3, Fast transients immunity test, level 3, 2 kV, conforming to EN/IEC 61000-4-4, Surge immunity test (common mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 |
| Part number | TPRAN2X1 |
|---|---|
| Type designation | TPRAN |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606489832902 |
| Warranty (in months) | 18 |
|---|
| Country of origin | ID |
|---|---|
| Shipping weight | 0.172 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for TPRAN is 853650.
The EAN (GTIN) of TPRAN is 3606489832902.
TPRAN ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Master AC-3 rating selection under IEC 60947-4-1 for contactors and motor starters, including utilization categories and coordination types. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Size a contactor for a 3-phase motor using IEC 60947-4-1 methodology, AC-3 vs AC-4 categories, NEMA equivalents, and Type 2 coordination. Shop at Stoklink.