Part number
TM262L20MESE8T
7,443.56 SR On request Dispatch — · From TürkiyeGet a Quote
Logic/motion controller - Modicon M262

Schneider Electric TM262L20MESE8T Modicon M262 Dual Ethernet 3ns/Instruction Programmable Logic Controller

Modicon M262 logic controller, 3ns/instruction, dual Ethernet (EtherNet/IP, Modbus TCP), 8 fast I/O, 24V DC.

Communication
Ethernet 1 (10/100BASE-T), Ethernet 2 (10/100/1000BASE-T), EtherNet/IP, Modbus TCP, RS232/RS485 serial, USB 2.0, Smart Communication Bus
EAN
3606489604196
Description

About the TM262L20MESE8T

The Schneider Electric TM262L20MESE8T is a Modicon M262 logic controller reaching 3 ns per instruction, with 8 fast digital I/O (4 inputs, 4 transistor outputs to 300 kHz) and dual Ethernet networks for EtherNet/IP and Modbus TCP. Powered by 24 V DC, it targets IIoT-ready machines needing embedded cloud connectivity, cybersecurity and an expandable TM3 I/O bus without dedicated motion control.

Certifications & Standards

  • CE
  • cULus
  • cULus HazLoc Class I Division 2
  • RCM
  • EAC
  • Achilles
  • KC
  • UL 61010-1
  • UL 61010-2-201
  • CSA C22.2 No 61010-1
  • CSA C22.2 No 61010-2-201
  • CSA C22.2 No 213
  • ANSI/ISA 12-12-01
  • IEC 61131-2

Selection Notes

Choose the TM262L20MESE8T over a 5 ns/instruction variant when scan-cycle speed is the limiting factor — its 3 ns/instruction execution and 128-device EtherNet/IP/Modbus TCP connection ceiling (versus roughly 96 on the slower variant) suit larger distributed Ethernet architectures. Like other logic-only M262 controllers it has no Sercos motion bus, so pick a motion-enabled M262 variant when synchronized axis control is required.

Specification

Full specification

88 values · Last verified 30 Oct 2026

Main 5

Range of Product Logic/motion controller - Modicon M262
Product or Component Type Logic controller
[Us] rated supply voltage 24 V DC - 15...20 %
Discrete I/O number 8
Upstream connectivity IIoT-ready machine to cloud, Connected machine to plant

Complementary 53

Supply voltage limits 20.4…28.8 V DC
PLC Power Consumption 82 W
Inrush current 40 A
Overvoltage protection With
Discrete input number 4, discrete input fast input IEC 61131-2 Type 1
Discrete input voltage 24 V
Discrete input voltage type DC
Discrete input logic Sink
Voltage state 1 guaranteed >= 15 V DC
Voltage state 0 guaranteed <= 5 V DC
Discrete input current 7.5 mA fast input
Input impedance 2.81 kOhm input
Response time <= 1 µs turn-on, I0...I3 fast input, <= 1 µs turn-off, I0...I3 fast input, <= 1 µs turn-on, Q0...Q3 fast output, <= 1 µs turn-off, Q0...Q3 fast output
Configurable filtering time 0.001 ms fast input, 0.002 ms fast input, 0.005 ms fast input, 0.01 ms fast input, 0.05 ms fast input, 0.1 ms fast input, 0.5 ms fast input, 1 ms fast input, 4 ms fast input, 12 ms fast input
Discrete output number 4 transistor fast output
Discrete output voltage 24 V DC
Discrete output current 0.5 A fast output Q0...Q3)
Discrete output type Transistor
Discrete output logic Source
Output voltage limits 30 V DC
Maximum current per output common 0.5 A Q0...Q3 fast output
Maximum output frequency 300 kHz
Accuracy +/- 0.1 % 0.02…0.1 kHz fast output, +/- 1 % 0.1…1 kHz fast output
Maximum leakage current 10 µA output
Maximum tungsten load <1.5 W
Protection type Short-circuit and overload protection with automatic reset, Reverse polarity protection, Short-circuit protection
Reset time 200 ms automatic reset fast output
Maximum number of I/O expansion module 7TM3 IO module (remote I/O-Architecture), 7TM3 IO module (local I/O-Architecture), 64TM3, TM5 or TM7 IO island (distributed I/O-Architecture)
Execution time for 1 KInstruction 0.003 ms
Memory capacity 32 MB program RAM, 32 MB OS/website RAM, 192 MB system memory RAM
Data backed up 1 GB built-in flash memory backup of user programs
Data storage equipment <= 32 GB SDHC card optional)
Backup time 1000 h 77 °F (25 °C)
Application structure 8 event tasks, 4 cyclic master tasks, 3 cyclic master tasks + 1 freewheeling task, 8 external event tasks
Realtime clock With
Clock drift <= 10 s/month 77 °F (25 °C)
Cycle time 0.5 ms
Positioning functions Libraries axes coordinated
Integrated connection type Ethernet 1 RJ45 10/100BASE-T, Ethernet 2 2 RJ45 100/1000BASE-T, Serial link RJ45 RS232/RS485, Smart Communication Bus, TM3 IO bus, USB type mini B
Transmission rate 115 kbit/s 49.2 ft (15 m) RS485, 115 kbit/s 9.8 ft (3 m) RS232, 480 Mbit/s 9.8 ft (3 m) USB, 10/100 Mbit/s Ethernet1, 10/100/1000 Mbit/s Ethernet2
Communication port protocol EtherNet/IP adapter, EtherNet/IP scanner, Modbus TCP client/server, Modbus TCP IO scanner, Modbus TCP NVL, Ethernet RSTP, Modbus SL client/server, Modbus SL IO scanner, Modbus SL modem management, Machine Expert, ASCII manager, ASCII modem management
Maximum Number of Connected Devices EtherNet/IP: 64, Modbus TCP: 64, Modbus TCP/EtherNet/IP: 128
Communication Service MQTTs, OPC UA server (Encrypt), OPC UA client (Encrypt), HTTPs Methods (API), Web server, Web visu, TLS 1.2, TLS 1.3, SNTP, NTP client/server, FTP client/server, FTPs server, SQL client (remote access), DHCP client, DHCP server, DNS client, POP3s client, SMTP client, SNMP client/server
Local signalling 1 LED (green/red) for PWR, 1 LED (green/red) for RUN, 1 LED (green/red) for ERROR (fault), 1 LED (green/red) for stop forced, 1 LED (green/red) for I/O error (I/O), 1 LED (green/orange) for SD card activity, 1 LED (green/orange) for SL activity, 1 LED (green/red) for ETH1 state, 1 LED (green/red) for ETH2 state, 1 LED (green/red) for EIP MS, 1 LED (green/red) for EIP NS
Electrical connection removable spring terminal block for inputs and outputs, removable spring terminal block for connecting the 24 V DC power supply
Maximum cable distance between devices Shielded cable <9.8 ft (3 m) fast input, Shielded cable <9.8 ft (3 m) fast output, Unshielded cable <164.04 ft (50 m) input, Unshielded cable <164.04 ft (50 m) output, Shielded cable <98.4 ft (30 m) RS485 link, Shielded cable <49.2 ft (15 m) RS232
Insulation Between fast input and internal logic 550 V AC, Non-insulated between inputs, Between output and internal logic 550 V AC, Non-insulated between outputs, Between input and output 550 V AC, Between supply and internal logic 550 V AC, Non-insulated between supply and ground
Surge withstand 1 kV power lines (DC) common mode IEC 61000-4-5, 1 kV shielded cable common mode IEC 61000-4-5, 0.5 kV relay output differential mode IEC 61000-4-5, 1 kV input common mode IEC 61000-4-5, 1 kV transistor output common mode IEC 61000-4-5
Mounting support Top hat type TH35-15 rail IEC 60715, Top hat type TH35-7.5 rail IEC 60715, plate or panel with fixing kit
Height 3.9 in (100 mm)
Depth 3.5 in (90 mm)
Width 4.9 in (125 mm)
Net Weight 1.444 lb(US) (0.655 kg)

Environment 17

Standards UL 61010-1, UL 61010-2-201, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, CSA C22.2 No 213, ANSI/ISA 12-12-01, IEC 61131-2
Product Certifications CE, cULus, cULus HazLoc Class I Division 2 CSA 22-2 No 213, RCM, EAC, Achilles, KC
Resistance to electrostatic discharge 4 kV on contact IEC 61000-4-2, 8 kV on air IEC 61000-4-2
Resistance to electromagnetic fields 9.1 V/m (10 V/m) 80 MHz...1 GHz IEC 61000-4-3, 2.7 V/m (3 V/m) 1.4 GHz...2 GHz IEC 61000-4-3, 0.9 V/m (1 V/m) 2 GHz...3 GHz IEC 61000-4-3
Resistance to fast transients 2 kV IEC 61000-4-4 power lines), 1 kV IEC 61000-4-4 Ethernet line), 1 kV IEC 61000-4-4 serial link), 1 kV IEC 61000-4-4 input), 1 kV IEC 61000-4-4 transistor output)
Resistance to conducted disturbances 10 V 0.15...80 MHz IEC 61000-4-4, 3 V 0.1...80 MHz, 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)
Electromagnetic emission Conducted emissions 120...69 dBµV/m QP power lines)10…150 kHz IEC 55011, Conducted emissions 63 dBμV/m QP power lines)1.5…30 MHz IEC 55011, Radiated emissions 40 dBµV/m30…230 kHz IEC 55011, Conducted emissions 79...63 dBμV/m QP power lines)150…1500 kHz IEC 55011, Radiated emissions230…1000 MHz IEC 55011
Immunity to microbreaks 0.01 ms
Ambient air temperature for operation -4…140 °F (-20…60 °C) horizontal installation), -4…122 °F (-20…50 °C) vertical installation), -4…113 °F (-20…45 °C) flat mounting)
Ambient Air Temperature for Storage -40…185 °F (-40…85 °C)
Relative humidity 10…95 %, without condensation in operation), 10…95 %, without condensation in storage)
IP degree of protection IP20
Pollution degree 2
Operating altitude 0...6561.68 ft (0...2000 m)
Storage altitude 0…9842.5 ft (0…3000 m)
Vibration resistance 3.5 mm 2…8.4 Hz symmetrical rail, 1 gn 8.4…200 Hz symmetrical rail, 3.5 mm 2…8.4 Hz panel mounting, 1 gn 8.4…200 Hz panel mounting
Shock resistance 15 gn 11 ms
Show all 88 specifications ↓ Show less ↑13 more values in Identification, Contractual warranty, Logistics.

Identification 7

Part number TM262L20MESE8T
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3606489604196

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin ID
Shipping weight 0.655 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for TM262L20MESE8T

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • cULus
  • CSA
  • CE
  • EAC
  • UL 61010-1
  • UL 61010-2-201
  • CSA C22.2 No 61010-1
  • CSA C22.2 No 61010-2-201
  • CSA C22.2 No 213
  • ANSI/ISA 12-12-01
  • IEC 61131-2
Quick answers

Questions about the TM262L20MESE8T

What is the HS code of TM262L20MESE8T for customs?

The tariff (HS) code on file for TM262L20MESE8T is 853710.

What is the EAN of TM262L20MESE8T?

The EAN (GTIN) of TM262L20MESE8T is 3606489604196.

Where does TM262L20MESE8T ship from, and how fast?

TM262L20MESE8T ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

Series

Schneider Electric Logic/motion controller - Modicon M262

Brand
Schneider Electric
Series
Logic/motion controller - Modicon M262
7,443.56 SR On request
Get a Quote
Quote

Get a Quote

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · TM262L20MESE8T

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart