Part number
TM241CE24R
2,266.11 SR On request Dispatch — · From TürkiyeGet a Quote
Modicon M241

Schneider Electric TM241CE24R Modicon M241 24 I/O 14DI 6DO Relay Ethernet Programmable Logic Controller

Modicon M241 logic controller, 24 I/O (6 relay + 4 transistor DO), Ethernet, 100-240 V AC.

Rated operational voltage
100–240 V AC
Communication
Ethernet (RJ45, Modbus TCP, EtherNet/IP, FTP, OPC UA server), USB, Serial 1 RS232/RS485, Serial 2 RS485
EAN
3606480648830
Description

About the TM241CE24R

The Schneider Electric TM241CE24R is a Modicon M241 logic controller with 24 discrete I/O - 14 inputs (8 fast) and 6 relay outputs plus 4 transistor outputs (4 fast) - running from a 100-240 V AC supply. It adds an embedded Ethernet port for Modbus TCP and EtherNet/IP alongside USB and dual RS232/RS485 serial ports.

Certifications & Standards

  • CE
  • RCM
  • cULus
  • UKCA
  • DNV-GL
  • ABS
  • LR
  • ANSI/ISA 12-12-01
  • CSA C22.2 No 142
  • CSA C22.2 No 213
  • IEC 61131-2:2007
  • Marine specification (LR, ABS, DNV, GL)
  • UL 508

Selection Notes

The TM241CE24R's embedded Ethernet port adds Modbus TCP, EtherNet/IP, FTP, and OPC UA server connectivity that transistor-only, non-Ethernet M241 base units lack, making it the base unit of choice where the controller needs to sit on a plant network rather than communicate over serial links alone. Its 6 relay outputs (2 A, up to 250 V AC) switch contactor coils and pilot loads directly without an interposing relay, while the 4 transistor outputs (4 fast, 100 kHz PLS) still support basic pulse-train positioning where the relay outputs cannot. The 100-240 V AC supply removes the need for a separate 24 V DC power supply in panels already running on line voltage.

Applications

Compact-machine automation needing plant-network connectivity - packaging, material handling, and machine-control panels running Modbus TCP or EtherNet/IP alongside relay-driven contactor and pilot-device switching.

Specification

Full specification

91 values · Last verified 30 Oct 2026

Main 8

Range of Product Modicon M241
Product or Component Type Logic controller
[Us] rated supply voltage 100...240 V AC
Discrete input number 14, discrete input 8 fast input IEC 61131-2 Type 1
Discrete output type Relay, Transistor
Discrete output number 6 relay, 4 transistor 4 fast output
Discrete output voltage 5...125 V DC relay output, 5...250 V AC relay output, 24 V DC transistor output
Discrete output current 2 A relay output Q4...Q9), 0.1 A fast output (PTO mode) TR0...TR3), 0.5 A transistor output TR0...TR3)

Complementary 53

Discrete I/O number 24
Maximum number of I/O expansion module 7 (local I/O-Architecture), 14 (remote I/O-Architecture)
Supply voltage limits 85…264 V
Network Frequency 50/60 Hz
Discrete input logic Sink or source
Discrete input voltage 24 V
Discrete input voltage type DC
Voltage state 1 guaranteed >= 15 V input
Voltage state 0 guaranteed <= 5 V input
Discrete input current 5 mA input
Input impedance 4.7 kOhm input
Response time 50 µs turn-on, I0...I13 input
Configurable filtering time 1 s fast input
Discrete output logic Positive logic (source)
Output voltage limits 125 V DC relay output, 30 V DC transistor output, 277 V AC relay output
Maximum output frequency 1 kHz transistor output, 20 kHz fast output (PWM mode), 100 kHz fast output (PLS mode)
Accuracy +/- 0.1 % 0.02…0.1 kHz fast output, +/- 1 % 0.1…1 kHz fast output
Protection type Short-circuit protection transistor output, Short-circuit and overload protection with automatic reset transistor output, Reverse polarity protection transistor output, Without protection relay output
Reset time 10 ms automatic reset output, 12 s automatic reset fast output
Memory capacity 64 MB system memory RAM
Data backed up 128 MB built-in flash memory backup of user programs
Data storage equipment <= 16 GB SD card optional)
Battery type BR2032 lithium non-rechargeable 4 year(s)
Backup time 2 years 77 °F (25 °C)
Execution time for 1 KInstruction 0.3 ms event and periodic task, 0.7 ms other instruction
Application structure 8 external event tasks, 3 cyclic master tasks + 1 freewheeling task, 8 event tasks, 4 cyclic master tasks
Realtime clock With
Clock drift <= 60 s/month 77 °F (25 °C)
Positioning functions PTO 4 100 kHz)
Counting input number 4 fast input (HSC mode) 200 kHz, 14 standard input 1 kHz
Control signal type A/B 100 kHz fast input (HSC mode), Pulse/direction 200 kHz fast input (HSC mode), Single phase 200 kHz fast input (HSC mode)
Integrated connection type Non isolated serial link serial 1 RJ45 RS232/RS485, Non isolated serial link serial 2 removable screw terminal block RS485, USB port mini B USB 2.0, Ethernet RJ45
Supply Serial 1)serial link supply 5 V, <200 mA
Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) 49.2 ft (15 m) RS485, 1.2...115.2 kbit/s (115.2 kbit/s by default) 9.8 ft (3 m) RS232, 480 Mbit/s 9.8 ft (3 m) USB, 10/100 Mbit/s Ethernet
Communication port protocol Non isolated serial link Modbus master/slave
Port Ethernet 10BASE-T/100BASE-TX - 1 copper cable
ethernet services FDR, DHCP server via TM4 Ethernet switch network module, DHCP client embedded Ethernet port, SMS notifications, Updating firmware, SNMP client/server, Programming, NGVL, Monitoring, IEC VAR ACCESS, FTP client/server, Downloading, SQL client, Modbus TCP client I/O scanner, Ethernet/IP originator I/O scanner embedded Ethernet port, Ethernet/IP target, Modbus TCP server and Modbus TCP slave, Send and receive email from the controller based on TCP/UDP library, Web server (WebVisu & XWeb system), OPC UA server, DNS client
Local signalling 1 LED (green) for PWR, 1 LED (green) for RUN, 1 LED (red) for module error (ERR), 1 LED (red) for I/O error (I/O), 1 LED (green) for SD card access (SD), 1 LED (red) for BAT, 1 LED (green) for SL1, 1 LED (green) for SL2, 1 LED (red) for bus fault on TM4 (TM4), 1 LED per channel (green) for I/O state, 1 LED (green) for Ethernet port activity
Electrical connection removable screw terminal block for inputs and outputs pitch 5.08 mm), removable screw terminal block for connecting the 24 V DC power supply pitch 5.08 mm)
Maximum cable distance between devices Unshielded cable <164.04 ft (50 m) input, Shielded cable <32.8 ft (10 m) fast input, Unshielded cable <164.04 ft (50 m) output, Shielded cable <9.8 ft (3 m) fast output
Insulation Between supply and internal logic 500 V AC, Non-insulated between supply and ground
Marking CE
Sensor power supply 24 V DC 400 mA supplied by the controller
Surge withstand 2 kV power lines (AC) common mode IEC 61000-4-5, 2 kV relay output common mode IEC 61000-4-5, 1 kV shielded cable common mode IEC 61000-4-5, 1 kV power lines (AC) differential mode IEC 61000-4-5, 1 kV relay output differential mode IEC 61000-4-5, 1 kV input common mode IEC 61000-4-5, 1 kV transistor output common mode IEC 61000-4-5
Web services Web server
Maximum number of connections 8 Modbus server, 8 SoMachine protocol, 10 web server, 4 FTP server, 16 Ethernet/IP target, 8 Modbus client
Number of server device(s) 64 Modbus TCP, 16 EtherNet/IP
Cycle time 10 ms 16 EtherNet/IP, 64 ms 64 Modbus TCP
Mounting support Top hat type TH35-15 rail IEC 60715, Top hat type TH35-7.5 rail IEC 60715, plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 3.7 in (95 mm)
Width 5.9 in (150 mm)
Net Weight 1.17 lb(US) (0.53 kg)

Environment 17

Standards ANSI/ISA 12-12-01, CSA C22.2 No 142, CSA C22.2 No 213, IEC 61131-2:2007, Marine specification (LR, ABS, DNV, GL), UL 508
Product Certifications RCM, cULus, CE, UKCA, DNV-GL, ABS, LR
Resistance to electrostatic discharge 8 kV in air IEC 61000-4-2, 4 kV on contact IEC 61000-4-2
Resistance to electromagnetic fields 9.1 V/m (10 V/m) 80 MHz...1 GHz IEC 61000-4-3, 2.7 V/m (3 V/m) 1.4 GHz...2 GHz IEC 61000-4-3, 0.9 V/m (1 V/m) 2 GHz...3 GHz IEC 61000-4-3
Resistance to fast transients 2 kV IEC 61000-4-4 power lines), 2 kV IEC 61000-4-4 relay output), 1 kV IEC 61000-4-4 Ethernet line), 1 kV IEC 61000-4-4 serial link), 1 kV IEC 61000-4-4 input), 1 kV IEC 61000-4-4 transistor output)
Resistance to conducted disturbances 10 V 0.15...80 MHz IEC 61000-4-6, 3 V 0.1...80 MHz Marine specification (LR, ABS, DNV, GL), 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
Electromagnetic emission Conducted emissions 120...69 dBµV/m QP power lines)10…150 kHz IEC 55011, Conducted emissions 63 dBμV/m QP power lines)1.5…30 MHz IEC 55011, Conducted emissions 79 dBμV/m QP/66 dBμV/m AV power lines)0.15…0.5 MHz IEC 55011, Conducted emissions 73 dBμV/m QP/60 dBμV/m AV power lines)0.5…300 MHz IEC 55011, Radiated emissions 40 dBμV/m QP class A 10 m)30…230 MHz IEC 55011, Conducted emissions 79...63 dBμV/m QP power lines)150…1500 kHz IEC 55011, Radiated emissions 47 dBμV/m QP class A 10 m)230…1000 MHz IEC 55011
Immunity to microbreaks 10 ms
Ambient air temperature for operation 14…122 °F (-10…50 °C) vertical installation), 14…131 °F (-10…55 °C) horizontal installation)
Ambient Air Temperature for Storage -13…158 °F (-25…70 °C)
Relative humidity 10…95 %, without condensation in operation), 10…95 %, without condensation in storage)
IP degree of protection IP20 with protective cover in place
Pollution degree 2
Operating altitude 0...6561.68 ft (0...2000 m)
Storage altitude 0…9842.5 ft (0…3000 m)
Vibration resistance 3.5 mm 5…8.4 Hz symmetrical rail, 3 gn 8.4…150 Hz symmetrical rail, 3.5 mm 5…8.4 Hz panel mounting, 3 gn 8.4…150 Hz panel mounting
Shock resistance 15 gn 11 ms
Show all 91 specifications ↓ Show less ↑13 more values in Identification, Contractual warranty, Logistics.

Identification 7

Part number TM241CE24R
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3606480648830

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin ID
Shipping weight 0.53 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for TM241CE24R

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • cULus
  • CE
  • UKCA
  • ANSI/ISA 12-12-01
  • CSA C22.2 No 142
  • CSA C22.2 No 213
  • IEC 61131-2:2007
  • Marine specification (LR
  • ABS
  • DNV
  • GL)
  • UL 508
Quick answers

Questions about the TM241CE24R

Which supply voltage is TM241CE24R rated for?

The rated operational voltage of TM241CE24R is 100–240 V AC.

What is the HS code of TM241CE24R for customs?

The tariff (HS) code on file for TM241CE24R is 853710.

What is the EAN of TM241CE24R?

The EAN (GTIN) of TM241CE24R is 3606480648830.

Where does TM241CE24R ship from, and how fast?

TM241CE24R ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

Series

Schneider Electric Modicon M241

Brand
Schneider Electric
Series
Modicon M241
2,266.11 SR On request
Get a Quote
Quote

Get a Quote

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · TM241CE24R

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart