How to Select an Interface Relay for PLC Outputs
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
The Schneider Electric TM241CE24R is a Modicon M241 logic controller with 24 discrete I/O - 14 inputs (8 fast) and 6 relay outputs plus 4 transistor outputs (4 fast) - running from a 100-240 V AC supply. It adds an embedded Ethernet port for Modbus TCP and EtherNet/IP alongside USB and dual RS232/RS485 serial ports.
The TM241CE24R's embedded Ethernet port adds Modbus TCP, EtherNet/IP, FTP, and OPC UA server connectivity that transistor-only, non-Ethernet M241 base units lack, making it the base unit of choice where the controller needs to sit on a plant network rather than communicate over serial links alone. Its 6 relay outputs (2 A, up to 250 V AC) switch contactor coils and pilot loads directly without an interposing relay, while the 4 transistor outputs (4 fast, 100 kHz PLS) still support basic pulse-train positioning where the relay outputs cannot. The 100-240 V AC supply removes the need for a separate 24 V DC power supply in panels already running on line voltage.
Compact-machine automation needing plant-network connectivity - packaging, material handling, and machine-control panels running Modbus TCP or EtherNet/IP alongside relay-driven contactor and pilot-device switching.
| Range of Product | Modicon M241 |
|---|---|
| Product or Component Type | Logic controller |
| [Us] rated supply voltage | 100...240 V AC |
| Discrete input number | 14, discrete input 8 fast input IEC 61131-2 Type 1 |
| Discrete output type | Relay, Transistor |
| Discrete output number | 6 relay, 4 transistor 4 fast output |
| Discrete output voltage | 5...125 V DC relay output, 5...250 V AC relay output, 24 V DC transistor output |
| Discrete output current | 2 A relay output Q4...Q9), 0.1 A fast output (PTO mode) TR0...TR3), 0.5 A transistor output TR0...TR3) |
| Discrete I/O number | 24 |
|---|---|
| Maximum number of I/O expansion module | 7 (local I/O-Architecture), 14 (remote I/O-Architecture) |
| Supply voltage limits | 85…264 V |
| Network Frequency | 50/60 Hz |
| Discrete input logic | Sink or source |
| Discrete input voltage | 24 V |
| Discrete input voltage type | DC |
| Voltage state 1 guaranteed | >= 15 V input |
| Voltage state 0 guaranteed | <= 5 V input |
| Discrete input current | 5 mA input |
| Input impedance | 4.7 kOhm input |
| Response time | 50 µs turn-on, I0...I13 input |
| Configurable filtering time | 1 s fast input |
| Discrete output logic | Positive logic (source) |
| Output voltage limits | 125 V DC relay output, 30 V DC transistor output, 277 V AC relay output |
| Maximum output frequency | 1 kHz transistor output, 20 kHz fast output (PWM mode), 100 kHz fast output (PLS mode) |
| Accuracy | +/- 0.1 % 0.02…0.1 kHz fast output, +/- 1 % 0.1…1 kHz fast output |
| Protection type | Short-circuit protection transistor output, Short-circuit and overload protection with automatic reset transistor output, Reverse polarity protection transistor output, Without protection relay output |
| Reset time | 10 ms automatic reset output, 12 s automatic reset fast output |
| Memory capacity | 64 MB system memory RAM |
| Data backed up | 128 MB built-in flash memory backup of user programs |
| Data storage equipment | <= 16 GB SD card optional) |
| Battery type | BR2032 lithium non-rechargeable 4 year(s) |
| Backup time | 2 years 77 °F (25 °C) |
| Execution time for 1 KInstruction | 0.3 ms event and periodic task, 0.7 ms other instruction |
| Application structure | 8 external event tasks, 3 cyclic master tasks + 1 freewheeling task, 8 event tasks, 4 cyclic master tasks |
| Realtime clock | With |
| Clock drift | <= 60 s/month 77 °F (25 °C) |
| Positioning functions | PTO 4 100 kHz) |
| Counting input number | 4 fast input (HSC mode) 200 kHz, 14 standard input 1 kHz |
| Control signal type | A/B 100 kHz fast input (HSC mode), Pulse/direction 200 kHz fast input (HSC mode), Single phase 200 kHz fast input (HSC mode) |
| Integrated connection type | Non isolated serial link serial 1 RJ45 RS232/RS485, Non isolated serial link serial 2 removable screw terminal block RS485, USB port mini B USB 2.0, Ethernet RJ45 |
| Supply | Serial 1)serial link supply 5 V, <200 mA |
| Transmission rate | 1.2...115.2 kbit/s (115.2 kbit/s by default) 49.2 ft (15 m) RS485, 1.2...115.2 kbit/s (115.2 kbit/s by default) 9.8 ft (3 m) RS232, 480 Mbit/s 9.8 ft (3 m) USB, 10/100 Mbit/s Ethernet |
| Communication port protocol | Non isolated serial link Modbus master/slave |
| Port Ethernet | 10BASE-T/100BASE-TX - 1 copper cable |
| ethernet services | FDR, DHCP server via TM4 Ethernet switch network module, DHCP client embedded Ethernet port, SMS notifications, Updating firmware, SNMP client/server, Programming, NGVL, Monitoring, IEC VAR ACCESS, FTP client/server, Downloading, SQL client, Modbus TCP client I/O scanner, Ethernet/IP originator I/O scanner embedded Ethernet port, Ethernet/IP target, Modbus TCP server and Modbus TCP slave, Send and receive email from the controller based on TCP/UDP library, Web server (WebVisu & XWeb system), OPC UA server, DNS client |
| Local signalling | 1 LED (green) for PWR, 1 LED (green) for RUN, 1 LED (red) for module error (ERR), 1 LED (red) for I/O error (I/O), 1 LED (green) for SD card access (SD), 1 LED (red) for BAT, 1 LED (green) for SL1, 1 LED (green) for SL2, 1 LED (red) for bus fault on TM4 (TM4), 1 LED per channel (green) for I/O state, 1 LED (green) for Ethernet port activity |
| Electrical connection | removable screw terminal block for inputs and outputs pitch 5.08 mm), removable screw terminal block for connecting the 24 V DC power supply pitch 5.08 mm) |
| Maximum cable distance between devices | Unshielded cable <164.04 ft (50 m) input, Shielded cable <32.8 ft (10 m) fast input, Unshielded cable <164.04 ft (50 m) output, Shielded cable <9.8 ft (3 m) fast output |
| Insulation | Between supply and internal logic 500 V AC, Non-insulated between supply and ground |
| Marking | CE |
| Sensor power supply | 24 V DC 400 mA supplied by the controller |
| Surge withstand | 2 kV power lines (AC) common mode IEC 61000-4-5, 2 kV relay output common mode IEC 61000-4-5, 1 kV shielded cable common mode IEC 61000-4-5, 1 kV power lines (AC) differential mode IEC 61000-4-5, 1 kV relay output differential mode IEC 61000-4-5, 1 kV input common mode IEC 61000-4-5, 1 kV transistor output common mode IEC 61000-4-5 |
| Web services | Web server |
| Maximum number of connections | 8 Modbus server, 8 SoMachine protocol, 10 web server, 4 FTP server, 16 Ethernet/IP target, 8 Modbus client |
| Number of server device(s) | 64 Modbus TCP, 16 EtherNet/IP |
| Cycle time | 10 ms 16 EtherNet/IP, 64 ms 64 Modbus TCP |
| Mounting support | Top hat type TH35-15 rail IEC 60715, Top hat type TH35-7.5 rail IEC 60715, plate or panel with fixing kit |
| Height | 3.5 in (90 mm) |
| Depth | 3.7 in (95 mm) |
| Width | 5.9 in (150 mm) |
| Net Weight | 1.17 lb(US) (0.53 kg) |
| Standards | ANSI/ISA 12-12-01, CSA C22.2 No 142, CSA C22.2 No 213, IEC 61131-2:2007, Marine specification (LR, ABS, DNV, GL), UL 508 |
|---|---|
| Product Certifications | RCM, cULus, CE, UKCA, DNV-GL, ABS, LR |
| Resistance to electrostatic discharge | 8 kV in air IEC 61000-4-2, 4 kV on contact IEC 61000-4-2 |
| Resistance to electromagnetic fields | 9.1 V/m (10 V/m) 80 MHz...1 GHz IEC 61000-4-3, 2.7 V/m (3 V/m) 1.4 GHz...2 GHz IEC 61000-4-3, 0.9 V/m (1 V/m) 2 GHz...3 GHz IEC 61000-4-3 |
| Resistance to fast transients | 2 kV IEC 61000-4-4 power lines), 2 kV IEC 61000-4-4 relay output), 1 kV IEC 61000-4-4 Ethernet line), 1 kV IEC 61000-4-4 serial link), 1 kV IEC 61000-4-4 input), 1 kV IEC 61000-4-4 transistor output) |
| Resistance to conducted disturbances | 10 V 0.15...80 MHz IEC 61000-4-6, 3 V 0.1...80 MHz Marine specification (LR, ABS, DNV, GL), 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL) |
| Electromagnetic emission | Conducted emissions 120...69 dBµV/m QP power lines)10…150 kHz IEC 55011, Conducted emissions 63 dBμV/m QP power lines)1.5…30 MHz IEC 55011, Conducted emissions 79 dBμV/m QP/66 dBμV/m AV power lines)0.15…0.5 MHz IEC 55011, Conducted emissions 73 dBμV/m QP/60 dBμV/m AV power lines)0.5…300 MHz IEC 55011, Radiated emissions 40 dBμV/m QP class A 10 m)30…230 MHz IEC 55011, Conducted emissions 79...63 dBμV/m QP power lines)150…1500 kHz IEC 55011, Radiated emissions 47 dBμV/m QP class A 10 m)230…1000 MHz IEC 55011 |
| Immunity to microbreaks | 10 ms |
| Ambient air temperature for operation | 14…122 °F (-10…50 °C) vertical installation), 14…131 °F (-10…55 °C) horizontal installation) |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
| Relative humidity | 10…95 %, without condensation in operation), 10…95 %, without condensation in storage) |
| IP degree of protection | IP20 with protective cover in place |
| Pollution degree | 2 |
| Operating altitude | 0...6561.68 ft (0...2000 m) |
| Storage altitude | 0…9842.5 ft (0…3000 m) |
| Vibration resistance | 3.5 mm 5…8.4 Hz symmetrical rail, 3 gn 8.4…150 Hz symmetrical rail, 3.5 mm 5…8.4 Hz panel mounting, 3 gn 8.4…150 Hz panel mounting |
| Shock resistance | 15 gn 11 ms |
| Part number | TM241CE24R |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606480648830 |
| Warranty (in months) | 18 |
|---|
| Country of origin | ID |
|---|---|
| Shipping weight | 0.53 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of TM241CE24R is 100–240 V AC.
The tariff (HS) code on file for TM241CE24R is 853710.
The EAN (GTIN) of TM241CE24R is 3606480648830.
TM241CE24R ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.