Part number
TM221M32TK
1,381.38 SR On request Dispatch — · From TürkiyeGet a Quote
Modicon M221

Schneider Electric TM221M32TK Modicon M221 Book 32 I/O Transistor Logic Controller

Modicon M221 Book logic controller, 32 I/O (16 DI/16 DO transistor), HE-10, 24V DC, IP20.

Communication
USB, Modbus RTU/ASCII master/slave via RS485/RS232
EAN
3606480611339
Description

About the TM221M32TK

The Schneider Electric TM221M32TK is a Modicon M221 Book-format logic controller with 32 discrete I/O — 16 inputs (4 fast) and 16 PNP transistor outputs (2 fast) — wired through HE-10 connectors in a 70 x 70 x 90 mm housing. Supplied from 24 V DC, each output switches 0.1 A (1.6 A per common), suited to dense low-current point counts.

Certifications & Standards

  • CE
  • cULus
  • LR
  • RCM
  • DNV-GL
  • EAC
  • ABS
  • UKCA
  • cULus HazLoc
  • IEC 61131-2
  • UL 508
  • CAN/CSA C22.2 No. 213
  • IACS E10
  • ANSI/ISA 12-12-01

Selection Notes

The TM221M32TK doubles the Book controller's I/O count to 32 points through HE-10 connectors instead of the 16-point models' screw terminals, which suits panel builders using pre-wired ribbon-cable harnesses. Its lower 0.1 A per-channel and 1.6 A per-common output rating reflects the higher channel density — it fits many low-current 24 V DC loads (PLC inputs, small relays) rather than a handful of higher-draw actuators.

Specification

Full specification

103 values · Last verified 30 Oct 2026

Main 9

Range of Product Modicon M221
Product or Component Type Logic controller
[Us] rated supply voltage 24 V DC
Discrete input number 16, discrete input 4 fast input IEC 61131-2 Type 1
Analogue input number 2 0...10 V
Discrete output type Transistor
Discrete output number 16 transistor 2 fast output
Discrete output voltage 24 V DC
Discrete output current 0.1 A

Complementary 61

Discrete I/O number 32
Maximum number of I/O expansion module 7 (local I/O-Architecture), 14 (remote I/O-Architecture)
Supply voltage limits 20.4…28.8 V
Inrush current 35 A
Maximum power consumption in W 22.3 W 24 V with max number of I/O expansion module), 3.5 W 24 V without I/O expansion module)
Power supply output current 0.52 A 5 V expansion bus, 0.48 A 24 V expansion bus
Discrete input logic Sink or source (positive/negative)
Discrete input voltage 24 V
Discrete input voltage type DC
Analogue input resolution 10 bits
LSB value 10 mV
Conversion time 1 ms per channel + 1 controller cycle time analog input
Permitted overload on inputs +/- 30 V DC 5 min maximum)analog input, +/- 13 V DC permanent)analog input
Voltage state 1 guaranteed >= 15 V input
Voltage state 0 guaranteed <= 5 V input
Discrete input current 7 mA discrete input, 5 mA fast input
Input impedance 3.4 kOhm discrete input, 100 kOhm analog input, 4.9 kOhm fast input
Response time 35 µs turn-off, I2...I5 input, 5 µs turn-on, I0, I1, I6, I7 fast input, 35 µs turn-on, other terminals input, 5 µs turn-off, I0, I1, I6, I7 fast input, 100 µs turn-off, other terminals input, 5 µs turn-on, turn-off, Q0...Q1 output, 50 µs turn-on, turn-off, Q2...Q3 output, 300 µs turn-on, turn-off, other terminals output
Configurable filtering time 0 ms input, 3 ms input, 12 ms input
Discrete output logic Positive logic (source)
Maximum current per output common 1.6 A
Output frequency 100 kHz fast output (PWM/PLS mode) Q0...Q1, 5 kHz output Q2...Q3, 0.1 kHz output Q4...Q15
Absolute accuracy error +/- 1 % of full scale analog input
Maximum leakage current 0.1 mA transistor output
Maximum voltage drop <1 V
Mechanical durability 20000000 cycles transistor output
Maximum tungsten load <2.4 W output and fast output
Protection type Short-circuit and overload protection with automatic reset, Short-circuit protection on output, Overload and short-circuit protection 0.2 A
Reset time 1 s automatic reset
Memory capacity 256 kB user application and data RAM 10000 instructions, 256 kB internal variables RAM
Data backed up 256 kB built-in flash memory backup of application and data
Data storage equipment 2 GB SD card optional)
Battery type BR2032 or CR2032X lithium non-rechargeable
Backup time 1 year 77 °F (25 °C) by interruption of power supply)
Execution time for 1 KInstruction 0.3 ms event and periodic task, 0.7 ms other instruction
Execution time per instruction 0.2 µs Boolean
Exct time for event task 60 µs response time
Application structure 1 configurable freewheeling/cyclic master task, 1 cyclic auxiliary task, 8 interrupt tasks
Maximum size of object areas 8000 %MW memory words, 255 %TM timers, 512 %KW constant words, 512 %M memory bits, 255 %C counters
Realtime clock With
Clock drift <= 30 s/month 77 °F (25 °C)
Regulation loop Adjustable PID regulator up to 14 simultaneous loops
Positioning functions PTO 2 pulse/direction 100 kHz), PTO 1 CW/CCW 100 kHz)
Function Available PLS, PWM, Frequency generator
Counting input number 4 fast input (HSC mode) 100 kHz 32 bits
counter function Single phase, A/B, Pulse/direction
Integrated connection type USB port mini B USB 2.0, Non isolated serial link serial 1 RJ45 RS485, Non isolated serial link serial 2 RJ45 RS232/RS485
Supply Serial 1)serial link supply 5 V, <200 mA
Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) 49.2 ft (15 m) RS485, 1.2...115.2 kbit/s (115.2 kbit/s by default) 9.8 ft (3 m) RS232, 480 Mbit/s USB
Communication port protocol USB port USB - SoMachine-Network, Non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network
Communication Service Modbus master, Modbus slave
Local signalling 1 LED (green) for PWR, 1 LED (green) for RUN, 1 LED (red) for module error (ERR), 1 LED (green) for SD card access (SD), 1 LED (red) for BAT, 1 LED (green) for SL1, 1 LED (green) for SL2, 1 LED per channel (green) for I/O state
Electrical connection terminal block, 3 for connecting the 24 V DC power supply, connector, 4 for analogue inputs, Mini B USB 2.0 connector for a programming terminal, HE-10 connector, 20 for inputs, HE-10 connector, 20 for outputs
Maximum cable distance between devices Shielded cable <32.8 ft (10 m) fast input, Unshielded cable <98.4 ft (30 m) output, Unshielded cable <98.4 ft (30 m) digital input, Unshielded cable <3.3 ft (1 m) analog input, Shielded cable <9.8 ft (3 m) fast output
Insulation Between input and internal logic 500 V AC, Between fast input and internal logic 500 V AC, Non-insulated between inputs, Between output and internal logic 500 V AC, Non-insulated between analogue input and internal logic, Non-insulated between analogue inputs
Marking CE
Mounting support Top hat type TH35-15 rail IEC 60715, Top hat type TH35-7.5 rail IEC 60715, plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 2.8 in (70 mm)
Width 2.8 in (70 mm)
Net Weight 0.60 lb(US) (0.27 kg)

Environment 20

Standards IEC 61131-2, UL 508, CAN/CSA C22.2 No. 213, IACS E10, ANSI/ISA 12-12-01
Product Certifications cULus, LR, RCM, DNV-GL, EAC, ABS, CE, UKCA, cULus HazLoc
Environmental characteristic Ordinary and hazardous location
Resistance to electrostatic discharge 8 kV in air IEC 61000-4-2, 4 kV on contact IEC 61000-4-2
Resistance to electromagnetic fields 9.1 V/m (10 V/m) 80 MHz...1 GHz IEC 61000-4-3, 2.7 V/m (3 V/m) 1.4 GHz...2 GHz IEC 61000-4-3, 0.9 V/m (1 V/m) 2...2.7 GHz IEC 61000-4-3
Resistance to magnetic fields 98.4 A/m (30 A/m) 50/60 Hz IEC 61000-4-8
Resistance to fast transients 2 kV IEC 61000-4-4 power lines), 2 kV IEC 61000-4-4 relay output), 1 kV IEC 61000-4-4 I/O), 1 kV IEC 61000-4-4 Ethernet line), 1 kV IEC 61000-4-4 serial link)
Surge withstand 2 kV power lines (AC) common mode IEC 61000-4-5, 2 kV relay output common mode IEC 61000-4-5, 1 kV I/O common mode IEC 61000-4-5, 1 kV shielded cable common mode IEC 61000-4-5, 0.5 kV power lines (DC) differential mode IEC 61000-4-5, 1 kV power lines (AC) differential mode IEC 61000-4-5, 1 kV relay output differential mode IEC 61000-4-5, 0.5 kV power lines (DC) common mode IEC 61000-4-5
Resistance to conducted disturbances 10 V 0.15...80 MHz IEC 61000-4-6, 3 V 0.1...80 MHz Marine specification (LR, ABS, DNV, GL), 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
Electromagnetic emission Conducted emissions 79 dBμV/m QP/66 dBμV/m AV power lines (AC))0.15…0.5 MHz IEC 55011, Conducted emissions 73 dBμV/m QP/60 dBμV/m AV power lines (AC))0.5…300 MHz IEC 55011, Conducted emissions 120...69 dBµV/m QP power lines)10…150 kHz IEC 55011, Conducted emissions 63 dBμV/m QP power lines)1.5…30 MHz IEC 55011, Radiated emissions 40 dBμV/m QP class A 10 m)30…230 MHz IEC 55011, Conducted emissions 79...63 dBμV/m QP power lines)150…1500 kHz IEC 55011, Radiated emissions 47 dBμV/m QP class A 10 m)200…1000 MHz IEC 55011
Immunity to microbreaks 10 ms
Ambient air temperature for operation 14…131 °F (-10…55 °C) horizontal installation), 14…95 °F (-10…35 °C) vertical installation)
Ambient Air Temperature for Storage -13…158 °F (-25…70 °C)
Relative humidity 10…95 %, without condensation in operation), 10…95 %, without condensation in storage)
IP degree of protection IP20 with protective cover in place
Pollution degree <= 2
Operating altitude 0...6561.68 ft (0...2000 m)
Storage altitude 0…9842.5 ft (0…3000 m)
Vibration resistance 3.5 mm 5…8.4 Hz symmetrical rail, 3.5 mm 5…8.4 Hz panel mounting, 1 gn 8.4…150 Hz symmetrical rail, 1 gn 8.4…150 Hz panel mounting
Shock resistance 147 m/s² 11 ms
Show all 103 specifications ↓ Show less ↑13 more values in Identification, Contractual warranty, Logistics.

Identification 7

Part number TM221M32TK
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3606480611339

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin TW
Shipping weight 0.27 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for TM221M32TK

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • cULus
  • CE
  • UKCA
  • EAC
  • IEC 61131-2
  • UL 508
  • CAN/CSA C22.2 No. 213
  • IACS E10
  • ANSI/ISA 12-12-01
Quick answers

Questions about the TM221M32TK

What is the HS code of TM221M32TK for customs?

The tariff (HS) code on file for TM221M32TK is 853710.

What is the EAN of TM221M32TK?

The EAN (GTIN) of TM221M32TK is 3606480611339.

Where does TM221M32TK ship from, and how fast?

TM221M32TK ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

Series

Schneider Electric Modicon M221

Brand
Schneider Electric
Series
Modicon M221
1,381.38 SR On request
Get a Quote
Quote

Get a Quote

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · TM221M32TK

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart