Part number
SSD1A335BDC1
Model no
SSD1
383.50 SR On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric SSD1A335BDC1 Harmony SSD1 35A 4-32V DC In 48-600V AC Out Solid State Relay

Harmony SSD1 DIN rail solid state relay, 35A, zero-voltage switching, 4-32V DC in, 48-600V AC out.

Rated current
35 A
EAN
3606489807894
Description

About the SSD1

The Schneider Electric SSD1A335BDC1 is a Harmony SSD1 DIN rail solid state relay rated 35 A with zero-voltage switching, a 4-32 V DC control input, and a 48-600 V AC load output. It mounts on 35 mm DIN rail, switches loads up to 7.46 kW/10 hp at 480 V AC, and carries a 600 V insulation rating.

Certifications & Standards

  • UL
  • CSA
  • UL 508
  • CSA C22.2 No 14-13
  • IEC 61373 Class B category 1
  • IEC 60947-4-3
  • IEC 62314
  • IEC 60950-1

Selection Notes

SSD1A335BDC1 covers motor loads up to 7.46 kW/10 hp at 480 V AC - roughly 3.3x the power handling of the 20 A SSD1 sibling in the same 22.5 mm DIN rail footprint, useful when panel space is fixed but load current scales up. Inrush current (1350 A at 60 Hz) is proportionally higher than the 20 A part's 300 A, so upstream short-circuit protection coordination (Type 1/Type 2) should be re-checked when stepping up from 20 A to 35 A. Same 4-32 V DC control input and 600 V insulation rating as the rest of the SSD1 zero-voltage-switching family.

Specification

Full specification

70 values · Last verified 30 Oct 2026

Main 9

Range of Product Harmony Solid State Relays
Product or Component Type Modular DIN rail relay
Device short name SSD1
Number of Channels 1
Number of phases 1 phase
Product configuration type Relay configuration
Mounting support 35 mm symmetrical DIN rail conforming to IEC 60715
rated current 35 A
Output switching mode Zero voltage switching

Complementary 39

operating frequency 47...440 Hz
Rated duty Uninterrupted
Output voltage 48...600 V AC
control circuit voltage 4...32 V DC
Tightening torque 1.5...1.7 N.m for control input, 13...15 lb.in for control input, 1.5...1.7 N.m for load output, 13...15 lb.in for load output
Connections - terminals screw terminals, clamping connection capacity:1...6 mm², 18 AWG...10 AWG for input, screw terminals, clamping connection capacity:1...6 mm², 18 AWG...10 AWG for output
Dielectric strength 4 kV AC for input/output circuit, 4 kV AC for input or output to case
rated impulse withstand voltage 6 kV for input/output circuit, 6 kV for input or output to case
Insulation resistance 1000 MOhm at 500 V DC
Local signalling LED (green) for control voltage
pick-up voltage 4 V DC turn-on
drop-out voltage 1 V DC turn-off
input current range 5…15 mA
solid state switching type Zero voltage switching
Load current 0.2…35 A
transient overvoltage 1200 V
Inrush current 1200 A at 60 Hz
Maximum voltage drop <1.3 V on-state
motor controller rating 1.5 kW/2 hp at 120 V AC, 3.73 kW/5 hp at 240 V AC, 7.46 kW/10 hp at 480 V AC
Electromagnetic compatibility Electrostatic discharge 6 kV criteria B contact discharge conforming to IEC 61000-4-2, Electrostatic discharge 8 kV criteria B air discharge conforming to IEC 61000-4-2, Conducted RF disturbances 10 V, 0.15...80 MHz criteria A level 3 conforming to IEC 61000-4-6, Electrical fast transient/burst immunity test 2 kV, 5/100 kHz criteria B output ports conforming to IEC 61000-4-4, Electrical fast transient/burst immunity test 1 kV, 5/100 kHz criteria B input ports conforming to IEC 61000-4-4, Radiated radio-frequency electromagnetic field immunity test 10 V/m, 80 MHz...1 GHz criteria A conforming to IEC 61000-4-3, Radiated radio-frequency electromagnetic field immunity test 3 V/m, 1.4...6 GHz criteria A conforming to IEC 61000-4-3, Surge immunity test 1 kV criteria B output ports line to line conforming to IEC 61000-4-5, Surge immunity test 2 kV criteria B output ports line to earth conforming to IEC 61000-4-5, Surge immunity test 1 kV criteria B input ports line to earth conforming to IEC 61000-4-5, Radiated emission environment A for DC input supply conforming to CISPR 11, Conducted emission environment A for DC input supply conforming to CISPR 11
device form designation Form 5 semiconductor output DOL contactor
Maximum I²t for fusing 7200 A².s for 10 ms, 6588 A².s for 8.33 ms
Maximum leakage current 1 mA off-state
DV/dt 500 V/µs off-state at maximum rated voltage
Response time 0.5 cycle (turn-on), 0.5 cycle (turn-off)
Power factor 0.5 with maximum load
short circuit protection coordination Type 1, Type 2
Overvoltage category III
Width 0.9 in (22.5 mm)
Height 3.7 in (95.0 mm)
Depth 4.6 in (117.0 mm)
test button Without test button
Net Weight 0.7 lb(US) (0.3 kg)
Device presentation Complete product
Protection device type TVS
Load Category LCA
Rated frequency (fr) 47...440 Hz
Utilisation category AC-51 35 A conforming to IEC 60947-4-3
[Ui] Rated Insulation Voltage 600 V

Environment 8

Flammability rating V-0 conforming to UL 94
Vibration resistance 0.75 mm (f = 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn for 11 ms (peak acceleration) , longitudinal position conforming to IEC 60068-2-27, 15 gn for 11 ms (peak acceleration) , vertical position conforming to IEC 60068-2-27
Pollution degree 2
Standards IEC 60947-4-3, IEC 62314, CSA C22.2 No 14-18, UL 508
IP degree of protection IP20
Ambient Air Temperature for Operation -40…176 °F (-40…80 °C)
Ambient Air Temperature for Storage -40…212 °F (-40…100 °C)
Show all 70 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number SSD1A335BDC1
Type designation SSD1
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3606489807894

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin CN
Shipping weight 0.3 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for SSD1A335BDC1

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • IEC 60947-4-3
  • IEC 62314
  • CSA C22.2 No 14-18
  • UL 508
Quick answers

Questions about the SSD1

What is the rated current of SSD1?

The rated current of SSD1 is 35 A.

What is the HS code of SSD1 for customs?

The tariff (HS) code on file for SSD1 is 85364900.

What is the EAN of SSD1?

The EAN (GTIN) of SSD1 is 3606489807894.

Where does SSD1 ship from, and how fast?

SSD1 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Reviews

Customer reviews

Series

Schneider Electric Harmony Solid State Relays

Brand
Schneider Electric
Series
Harmony Solid State Relays
Series page →
383.50 SR On request
Get a Quote
Quote

Get a Quote

SSD1

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · SSD1A335BDC1

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart