Schneider Zelio vs ABB CM: Monitoring Relay Comparison
A function-by-function comparison of Schneider Zelio Control and ABB CM monitoring relays covering three-phase supply, voltage, current, level, temperature, module width, and measurement method.
The Schneider Electric RM35S0MW is a Harmony RM35-S speed control relay, detecting overspeed or underspeed from a 3-wire PNP/NPN, NAMUR, voltage or volt-free sensor input while powered from a 24-240 V AC/DC supply. It switches a single 5 A changeover contact with a 0.6-60 second inhibit delay on startup, in a 35 mm wide DIN rail housing.
RM35S0MW accepts four different sensor wiring types - 3-wire PNP/NPN, NAMUR, 0-30 V voltage or a volt-free contact - on the same input, so the same part number covers proximity switches, inductive NAMUR sensors in hazardous-area interfaces, or a simple dry contact without changing hardware. The 0.6-60 s inhibit timer on energisation masks the slow ramp-up of a motor or conveyor at startup so the underspeed output does not nuisance-trip before the load reaches running speed. An immunity to supply microbreaks of up to 50 ms and an operating rate of up to 360 cycles per hour under full load let RM35S0MW ride through momentary sensor-supply dropouts without a false trip, useful on conveyor and fan applications sited near electrically noisy variable-speed drives.
| Range of Product | Harmony Control Relays |
|---|---|
| Relay Type | Speed control relays |
| Product or Component Type | Speed control relay |
| Relay name | RM35S |
| Relay monitored parameters | Overspeed, Underspeed |
| Time delay range | 0.6...60 s adjustable on energisation 0...10 % of the full scale value) |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 mA 5 V DC |
| Maximum power consumption in VA | 5 VA AC |
| Measurement range | 0.05...0.5 s, 0.5...5 min, 1...10 min, 1...10 s, 0.5...5 s, 0.1...1 s, 0.1...1 min |
| Utilisation category | AC-12 IEC 60947-5-1, AC-13 IEC 60947-5-1, AC-14 IEC 60947-5-1, AC-15 IEC 60947-5-1, DC-12 IEC 60947-5-1, DC-13 IEC 60947-5-1, DC-14 IEC 60947-5-1 |
| time delay | Adjustable 0.6...60 s Ti- inhibition time delay upon startup |
| rest time in memory mode | 50 ms contact S2 in memory mode on time delay, 1 s supply Un in memory mode on time delay |
|---|---|
| Maximum switching voltage | 250 V AC/DC |
| [Un] rated nominal voltage | 24...240 V AC/DC 50/60 Hz, non self-powered |
| Supply voltage limits | 20.4…264 V AC/DC |
| Maximum power consumption in W | 3 W DC |
| Width | 1.4 in (35 mm) |
| Output contacts | 1 C/O |
| Contacts material | Cadmium free |
| nominal output current | 5 A |
| delay at power up | 0.05 s |
| Hysteresis | 5 % threshold |
| Measurement accuracy | +/- 10 % of the full scale value |
| Repeat accuracy | +/- 0.5 % input and measurement circuit, +/- 0.5 % time delay |
| Measurement error | +/- 0.1 %/°C with temperature variation, < +/- 1 % over the whole range with voltage variation |
| Input frequency | 0.0017…20 Hz |
| Response time | 15 ms max (on crossing the threshold) |
| Polarity | Reversible polarity on DC supply |
| Threshold setting | 10...100 % |
| supply voltage for sensor | 11.5...12.5 V |
| Maximum supply current for sensors | 40 mA < 24 V AC 77 °F (25 °C), 40 mA < 24 V DC 77 °F (25 °C), 50 mA 24...240 V AC, 50 mA 24...240 V DC |
| Impulse duration | >= 5 ms high state, >= 5 ms low state |
| Input compatibility | 3-wire sensor (E1) PNP or NPN, 12 V, 50 mA, NAMUR sensor (E2), 12 V, 1.5 kOhm, Voltage input (E1), 0...30 V, 9.5 kOhm >= 4.5 V <= 1 V, Volt-free contact input (E1), 12 V, 9.5 kOhm |
| Marking | CE : EMC 89/336/EEC, CE : 73/23/EEC |
| Overvoltage category | III conforming to IEC 60664-1 |
| Insulation resistance | > 500 MOhm 500 V DC between supply and relay output IEC 60255-5, > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1, > 1 MOhm 500 V DC between supply and measurement IEC 60255-5, > 500 MOhm 500 V DC between supply and relay output IEC 60664-1, > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5, > 1 MOhm 500 V DC between supply and measurement IEC 60664-1 |
| [Ui] rated insulation voltage | 250 V IEC 60664-1 |
| operating voltage tolerance | - 15 % + 10 % Un |
| Supply frequency | 50/60 Hz +/- 10 % |
| Operating position | Any position without derating |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² 20 AWG...11 AWG) solid without cable end, Screw terminals, 2 x 0.5...2 x 2.5 mm² 20 AWG...14 AWG) solid without cable end, Screw terminals, 1 x 0.2...1 x 2.5 mm² 24 AWG...12 AWG) flexible with cable end, Screw terminals, 2 x 0.2...2 x 1.5 mm² 24 AWG...16 AWG) flexible with cable end |
| Tightening torque | 5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1 |
| Housing material | Polycarbonate |
| Status LED | 1 LED Green power ON, 1 LED Yellow inhibit, 1 LED Yellow relay (R) |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Operating rate | <= 360 operations/hour full load |
| Control Type | Without test button |
| Immunity to microbreaks | 50 ms |
|---|---|
| Electromagnetic compatibility | Emission standard for industrial environments IEC 61000-6-4, Emission standard for residential, commercial and light-industrial environments IEC 61000-6-3, Immunity for industrial environments NF EN/IEC 61000-6-2 |
| Standards | NF EN 60255-6, IEC 60255-6 |
| Product Certifications | C-tick, GOST, UL, GL, CSA |
| Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
| Ambient Air Temperature for Operation | -4…122 °F (-20…50 °C) |
| Relative humidity | 95 % 131 °F (55 °C) IEC 60068-2-30 |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1, 1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 |
| Shock resistance | 15 gn 11 ms IEC 60255-21-1 |
| IP degree of protection | IP20 IEC 60529 terminals), IP30 IEC 60529 casing) |
| Pollution degree | 3 IEC 60664-1 |
| Dielectric test voltage | 2 kV AC 50 Hz |
| Non-dissipating shock wave | 4 kV |
| Part number | RM35S0MW |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3389119405256 |
| Warranty (in months) | 18 |
|---|
| Country of origin | ID |
|---|---|
| Shipping weight | 0.133 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of RM35S0MW is 5 A.
The rated operational voltage of RM35S0MW is 24–240–DC V DC.
The tariff (HS) code on file for RM35S0MW is 853649.
The EAN (GTIN) of RM35S0MW is 3389119405256.
RM35S0MW ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A function-by-function comparison of Schneider Zelio Control and ABB CM monitoring relays covering three-phase supply, voltage, current, level, temperature, module width, and measurement method.
A step-by-step selection guide for phase and voltage monitoring relays, covering function match, auxiliary supply, threshold setting, output logic, and Schneider vs ABB CM...
How conductive level monitoring relays detect liquid presence, size sensitivity for the medium, and control pump up/down cycles with dry-run protection.