Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Schneider Electric NTSDRA0615K is a Modicon Edge I/O NTS relay output module kit with 6 isolated form-A (NO) relay channels rated 2 A, pre-assembled on its NTSXBA0100H base. Each channel switches 5...125 V DC or 24...250 V AC loads through a 2-wire connection, covering a -20...60 degC operating range. It mounts on a DIN rail and connects to Modicon M262 or M580 controllers.
The form-A (NO-only) relay contacts on the NTSDRA0615K suit simple on/off actuation such as pilot lamps or contactor coils where only a normally-open path is needed; for applications requiring both NO and NC feedback on the same point, the NTSDRC0215K/0415K form-C modules are the correct choice instead. The dual AC/DC voltage window (5...125 V DC, 24...250 V AC) lets the same relay switch either a 24 V DC control circuit or a 230 V AC load without a separate module. The 1780 V AC inter-channel isolation allows each of the 6 channels to reference a different circuit safely.
| Range of Product | Modicon Edge I/O NTS |
|---|---|
| Product or Component Type | Discrete output module kit |
| Kit composition | NTSDRA0615 module, NTSXBA0100H base |
| Mandatory accessory | NTSXTB12_1_H terminal block |
| Product Compatibility | NTSN..... |
| Range Compatibility | Logic/motion controller - Modicon M262, Modicon M580, Third party |
| Device Application | Industrial Application |
| Discrete output number | 6 |
| Group of output channels | 6 groups of 1 channels |
| Discrete output voltage | 24...250 V AC, 5...125 V DC |
| Operating Mode | Asynchronous |
| Discrete output number | 6 relay outputs (form A with NO) |
|---|---|
| Output wiring mode | 2 wires |
| Discrete output current | 2 A maximum per output at 30 Vdc or 250 Vac (inductive/resistive), 0.2 A maximum per output at 125 Vdc (resistive) |
| Minimum switching current | 10 mA 5 V DC |
| Discrete output frequency | 2 Hz for resistive load, 0.5 Hz for inductive load, 2 Hz for lamp load |
| Response time on output | < 10 ms deactivation, < 20 ms activation |
| Mechanical durability | 2000000 cycles |
| [Ith] conventional free air thermal current | 2 A per channel |
| Paralleling of outputs | Yes for logic links, Yes for redundant control of load |
| Output diagnostic | Power supply error per channel |
| Electrical durability | 150000 cycles 2 A 250/30 V AC/DC resistive, 100000 cycles 2 A 250/30 V AC/DC inductive, 300000 cycles 1 A 250/30 V AC/DC |
| Power supply type | Bus power from power supply bus (24 Vdc), Field power from power supply field (5...125 Vdc or 24...250 Vac) |
| Rated operational voltage limits | 20.4...28.8 V DC |
| Typical current consumption | 31.2 mA 24 V DC on the Bus current, 1.2 mA 24 V DC on the internal field current minimum, 41.4 mA 24 V DC on the internal field current maximum |
| Electrical Connection | Screw/spring terminal block |
| Power dissipation in W | 2.23 W maximum at 24 V DC |
| Isolation between channels | 1780 V AC |
| Isolation between channels and bus | 3000 V AC |
| Isolation between channels and ground | 3000 V AC |
| Hot swapping fallback | Yes |
| Local signalling | 1 LED (green) for module operating (RUN), 1 LED per channel (green) for channel diagnostic, 1 LED (red) for module error (ERR) |
| Housing Colour | Grey |
| Mounting support | Top hat type TH35-7.5 rail IEC 60715, Top hat type TH35-15 rail IEC 60715 |
| Height | 3.9 in (100 mm) |
| Width | 1.2 in (30 mm) |
| Depth | 3.1 in (80 mm) |
| Net Weight | 0.271 lb(US) (0.123 kg) |
| IP Degree of Protection | IP20 |
|---|---|
| Marking | CE, UKCA, CULus, RCM |
| Product certifications | CE, UKCA, CULus, RCM, Merchant Navy - EU RO MR (pending), EAC (pending), ATEX Zone 2 (pending), IECEx zone 2 (pending), CCC Ex zone 2 (pending) |
| Standards | EN/IEC 61131-2, EN 61010-2-201, UL 61010-2-201, IACS E10, EN/IEC 61000-6-5, interface type 1 and type 2, EN/IEC 61850-3, location G, EN/IEC 60079-0, EN 50155, EN 50121-4, EN 50121-5 |
| Directives | 2014/30/EU - electromagnetic compatibility, 2014/34/EU - ATEX directive, 2014/35/EU - directive basse tension |
| Ambient air temperature for operation | -4…140 °F (-20…60 °C) |
| Ambient air temperature for storage | -40…185 °F (-40…85 °C) |
| Relative humidity | 5…95 % without condensation |
| Operating altitude | 0...6561.68 ft (0...2000 m) without derating, 2000...5000 m with derating |
| Pollution degree | 2 |
| Vibration resistance | 1 g without accessory, 2 g with accessory |
| Shock resistance | 15 g 11 ms with and without accessory) |
| Part number | NTSDRA0615K |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606486877784 |
| Warranty (in months) | 18 |
|---|
| Country of origin | ID |
|---|---|
| Shipping weight | 0.123 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for NTSDRA0615K is 853710.
The EAN (GTIN) of NTSDRA0615K is 3606486877784.
NTSDRA0615K ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.