The Schneider Electric NTSDDO1602XAHK is a Modicon Edge I/O NTS discrete output module kit with 16 transistor outputs at 24 V DC, 500 mA per channel, split across 2 groups of 8, pre-assembled on its NTSXBA0200H base for severe-environment use. Channels wire in 1 or 2 wires and draw field power from an external 24 V DC supply, running across an extended -40...70 degC range with conformal-coated electronics. It mounts on a DIN rail and connects to Modicon M262 or M580 controllers.
The 500 V AC group-to-group isolation on the NTSDDO1602XAHK means a field-side fault on one 8-channel group does not propagate to the other, worth the wider 30 mm footprint when the panel drives two electrically separate load circuits. External 24 V DC field power keeps output current off the internal bus supply, so size that external supply for the full 8 A module rating. The hardened build's conformal coating and -40...70 degC range are the reason to choose it over the standard NTSDDO1602XAK when the enclosure sees vibration or condensation.
| Range of Product | Modicon Edge I/O NTS |
|---|---|
| Product or Component Type | Discrete output module kit |
| Kit composition | NTSDDO1602XAH module, NTSXBA0200H base |
| Mandatory accessory | 2x NTSXTB18_0_XH terminal block |
| Product Compatibility | NTSN..... |
| Range Compatibility | Logic/motion controller - Modicon M262, Modicon M580, Third party |
| Device Application | Industrial application in severe environment |
| Discrete output number | 16 |
| Group of output channels | 2 groups of 8 channels |
| Discrete output logic | Positive logic (source) |
| Discrete output voltage | 24 V DC |
| Operating Mode | Synchronous/Isochronous |
| Discrete output number | 16 transistor |
|---|---|
| Output wiring mode | 1 or 2 wires |
| Discrete output current | 500 mA per channel, 4 A per group, 8 A per module |
| Discrete output frequency | 1 kHz for resistive load, 0.5/LI² Hz for inductive load |
| Response time on output | 90 µs maximum (turn on), 110 µs maximum (turn off) |
| Maximum leakage current | 0.0001 mA per channel |
| Maximum voltage drop | <0.1 V per channel DC |
| Maximum tungsten load | <12 W |
| Paralleling of outputs | Yes for redundancy, Yes for double current, Yes for same group (maxium 2) |
| Output protection type | Transient voltage suppression per channel, Short circuit protection per channel, Overload/thermal protection per channel |
| Output diagnostic | External power supply error per channel, Short circuit error per channel |
| Power supply type | Bus power from power supply bus (24 Vdc), Field power from external power supply (24 Vdc) |
| Rated operational voltage limits | 20.4...28.8 V DC |
| Typical current consumption | 42 mA 24 V DC on the Bus current, 0 mA 24 V DC on the internal field current |
| Electrical Connection | Screw/spring terminal block |
| Power dissipation in W | 2.51 W maximum at 24 V DC |
| Isolation between group | 500 V AC |
| Isolation between channels and bus | 1500 V AC |
| Isolation between channels and ground | 1500 V AC |
| Hot swapping fallback | Yes |
| Local signalling | 1 LED (green) for module operating (RUN), 1 LED per channel (green) for channel diagnostic, 1 LED (red) for module error (ERR) |
| Housing Colour | Grey |
| Mounting support | Top hat type TH35-7.5 rail IEC 60715, Top hat type TH35-15 rail IEC 60715 |
| Height | 5.4 in (137.6 mm) |
| Width | 1.2 in (30 mm) |
| Depth | 3.2 in (81 mm) |
| Net Weight | 0.289 lb(US) (0.131 kg) |
| IP Degree of Protection | IP20 |
|---|---|
| Protective treatment | Conformal coating |
| Marking | CE, UKCA, CULus, RCM |
| Product certifications | CE, UKCA, CULus, RCM, Merchant Navy - EU RO MR (pending), EAC (pending), ATEX Zone 2 (pending), IECEx zone 2 (pending), CCC Ex zone 2 (pending) |
| Standards | EN/IEC 61131-2, EN 61010-2-201, UL 61010-2-201, IACS E10, EN/IEC 61000-6-5, interface type 1 and type 2, EN/IEC 61850-3, location G, EN/IEC 60079-0, EN 50155, EN 50121-4, EN 50121-5 |
| Directives | 2014/30/EU - electromagnetic compatibility, 2014/34/EU - ATEX directive, 2014/35/EU |
| Ambient air temperature for operation | -40…158 °F (-40…70 °C) |
| Ambient air temperature for storage | -40…185 °F (-40…85 °C) |
| Relative humidity | 5…95 % without condensation |
| Operating altitude | 0...6561.68 ft (0...2000 m) without derating, 2000...5000 m with derating |
| Pollution degree | 2 |
| Environmental characteristic | Gas resistant CX & GX combined, Salt spray resistant |
| Vibration resistance | 1 g without accessory, 2 g with accessory |
| Shock resistance | 15 g 11 ms with and without accessory) |
| Part number | NTSDDO1602XAHK |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606486877722 |
| Warranty (in months) | 18 |
|---|
| Country of origin | ID |
|---|---|
| Shipping weight | 0.131 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for NTSDDO1602XAHK is 853710.
The EAN (GTIN) of NTSDDO1602XAHK is 3606486877722.
NTSDDO1602XAHK ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.