The Schneider Electric NTSDDO0802K is a Modicon Edge I/O NTS discrete output module kit with 8 transistor outputs at 24 V DC, 2 A per channel, pre-assembled on its NTSXBA0100H base. Channels wire in a single-wire connection across 2 groups of 4 and draw field power from an external 24 V DC supply, covering a -20...60 degC operating range. It mounts on a DIN rail and connects to Modicon M262 or M580 controllers.
The 2 A per-channel rating on the NTSDDO0802K, four times the 500 mA of the NTSDDO0602K/0402K, suits solenoid valves and small motor starters driven directly from the I/O module. Field power comes from an external 24 V DC supply rather than the internal bus-power path, so the supply's current capacity must cover the 8 A module maximum when all channels run at rated load simultaneously. Grouping the 8 channels into two 4-channel groups lets the controller isolate a field-side fault to half the module rather than the whole output set.
| Range of Product | Modicon Edge I/O NTS |
|---|---|
| Product or Component Type | Discrete output module kit |
| Kit composition | NTSDDO0802 module, NTSXBA0100H base |
| Mandatory accessory | NTSXTB12_0_H terminal block |
| Product Compatibility | NTSN..... |
| Range Compatibility | Logic/motion controller - Modicon M262, Modicon M580, Third party |
| Device Application | Industrial Application |
| Discrete output number | 8 |
| Group of output channels | 2 groups of 4 channels |
| Discrete output logic | Positive logic (source) |
| Discrete output voltage | 24 V DC |
| Operating Mode | Synchronous/Isochronous |
| Discrete output number | 8 transistor |
|---|---|
| Output wiring mode | 1 wire |
| Discrete output current | 2 A per channel, 4 A per group, 8 A per module |
| Discrete output frequency | 1 kHz for resistive load, 0.5/LI² Hz for inductive load |
| Response time on output | 90 µs maximum (turn on), 110 µs maximum (turn off) |
| Maximum leakage current | 0.001 mA per channel |
| Maximum voltage drop | <0.25 V per channel DC |
| Maximum tungsten load | <12 W |
| Output protection type | Transient voltage suppression per channel, Short circuit protection per channel, Overload/thermal protection per channel |
| Output diagnostic | External power supply error per channel, Over current error per channel |
| Power supply type | Bus power from power supply bus (24 Vdc), Field power from external power supply (24 Vdc) |
| Rated operational voltage limits | 20.4...28.8 V DC |
| Typical current consumption | 33.6 mA 24 V DC on the Bus current, 0 mA 24 V DC on the internal field current |
| Electrical Connection | Screw/spring terminal block |
| Power dissipation in W | 1.68 W maximum at 24 V DC |
| Isolation between channels and bus | 1500 V AC |
| Isolation between channels and ground | 1500 V AC |
| Hot swapping fallback | Yes |
| Local signalling | 1 LED (green) for module operating (RUN), 1 LED per channel (green) for channel diagnostic, 1 LED (red) for module error (ERR) |
| Housing Colour | Grey |
| Mounting support | Top hat type TH35-7.5 rail IEC 60715, Top hat type TH35-15 rail IEC 60715 |
| Height | 3.9 in (100 mm) |
| Width | 0.6 in (15 mm) |
| Depth | 3.1 in (80 mm) |
| Net Weight | 0.159 lb(US) (0.072 kg) |
| IP Degree of Protection | IP20 |
|---|---|
| Marking | CE, UKCA, CULus, RCM |
| Product certifications | CE, UKCA, CULus, RCM, Merchant Navy - EU RO MR (pending), EAC (pending), ATEX Zone 2 (pending), IECEx zone 2 (pending), CCC Ex zone 2 (pending) |
| Standards | EN/IEC 61131-2, EN 61010-2-201, UL 61010-2-201, IACS E10, EN/IEC 61000-6-5, interface type 1 and type 2, EN/IEC 61850-3, location G, EN/IEC 60079-0, EN 50155, EN 50121-4, EN 50121-5 |
| Directives | 2014/30/EU - electromagnetic compatibility, 2014/34/EU - ATEX directive, 2014/35/EU |
| Ambient air temperature for operation | -4…140 °F (-20…60 °C) |
| Ambient air temperature for storage | -40…185 °F (-40…85 °C) |
| Relative humidity | 5…95 % without condensation |
| Operating altitude | 0...6561.68 ft (0...2000 m) without derating, 2000...5000 m with derating |
| Pollution degree | 2 |
| Vibration resistance | 1 g without accessory, 2 g with accessory |
| Shock resistance | 15 g 11 ms with and without accessory) |
| Part number | NTSDDO0802K |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606486877692 |
| Warranty (in months) | 18 |
|---|
| Country of origin | ID |
|---|---|
| Shipping weight | 0.072 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for NTSDDO0802K is 853710.
The EAN (GTIN) of NTSDDO0802K is 3606486877692.
NTSDDO0802K ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.