- Part number
- METSECT5HJ075
Description
About the METSECT5HJ075
About the METSECT5HJ075
The Schneider Electric METSECT5HJ075 is a PowerLogic Type HJ split-core current transformer for cable mounting, ratio 750/5 A, Class 0.5 accuracy at 2.5 VA. It clips around a cable up to 42.4 mm diameter without opening the circuit, supplying a standard 5 A secondary to a power meter or protection relay on a 750 A feeder.
Certifications & Standards
- DIN EN 60044-1
- DIN EN 61869-1
- DIN EN 61869-2
- VDE 0414
Selection Notes
The METSECT5HJ075 clamps onto a cable up to 42.4 mm diameter for a 750 A feeder without breaking the conductor, which is the main reason to pick a HJ split-core type over a solid-core busbar transformer. Class 0.5 accuracy makes it suitable for revenue-grade or sub-billing energy metering, not just coarse load indication. Choose the next current rating in the HJ series if the measured feeder load exceeds 750 A, since the window size stays the same across the family.
Applications
The clip-on HJ body lets a panel builder add the METSECT5HJ075 to an existing 750 A cable run during a metering or protection upgrade, without disconnecting the conductor or shutting down the circuit to fit the transformer.
Specification
Full specification
Main 6
| Range | PowerLogic |
|---|---|
| Product or component type | Current transformer |
| Product name | CT |
| Secondary current | 5 A |
| Accuracy class | Class 0.5 at 2.5 VA |
| [In] rated current | 750 A |
Complementary 15
| Current transformer type | Standard for cable, Split core |
|---|---|
| Current transformer ratio | 750/5 |
| [Ith] conventional free air thermal current | 900 A |
| Maximum safety factor | 5 |
| Permissible current | 45000 A during 1 s |
| [Ue] rated operational voltage | < 720 V 50 Hz |
| [Ui] rated insulation voltage | 3 kV 50 Hz for 1 minute |
| Mounting mode | Clip-on |
| Width | Outside: 67 mm |
| Height | Outside: 96 mm |
| Depth | 69 mm |
| Diameter | 42.4 mm inner: |
| Electrical insulation class | Class E |
| Cable outer diameter | 42.4 mm |
| Connections - terminals | Cable 2 cable(s) 0.5…1.5 mm² 0.5 m |
Environment 3
| Standards | DIN EN 60044-1, DIN EN 61869-1, DIN EN 61869-2, VDE 0414 |
|---|---|
| Ambient air temperature for operation | -5…50 °C |
| Ambient air temperature for storage | -25…70 °C |
Show all 47 specifications ↓ Show less ↑23 more values in Identification, Contractual warranty, Logistics.
Identification 6
| Part number | METSECT5HJ075 |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
Contractual warranty 1
| Warranty (in months) | 18 |
|---|
Logistics 16
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.5 cm |
| Package 1 Width | 7.0 cm |
| Package 1 Length | 10.0 cm |
| Package 1 Weight | 474.0 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 8.06 kg |
| Shipping weight | 0.474 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
Documents
Documents for METSECT5HJ075
No documents are on file for this part yet.
Ask us for the datasheet
Certifications
Certifications and standards
- DIN EN 60044-1
- DIN EN 61869-1
- DIN EN 61869-2
- VDE 0414
Quick answers
Questions about the METSECT5HJ075
What is the rated current of METSECT5HJ075?
The rated current of METSECT5HJ075 is 750 A.
What is the HS code of METSECT5HJ075 for customs?
The tariff (HS) code on file for METSECT5HJ075 is 850431.
Where does METSECT5HJ075 ship from, and how fast?
METSECT5HJ075 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.