The Schneider Electric LV947365 is an MX opening coil for fixed MasterPacT MTZ1 and MTZ2 Active circuit breakers fitted with the MicroLogic Active control unit, supplied for 380-480 V AC 50/60 Hz only. Energizing the coil trips the breaker open within 60 ms once voltage reaches 0.7-1.1 Un. It is sold as a single piece with an instruction sheet for installation.
The LV947365 is the AC-only, 380-480 V top of the MX opening-coil range, while the 100-130 V and 200-250 V siblings also accept DC supply; confirm the shunt-trip source is AC before ordering it. Like the rest of the MX family it is limited to MTZ1 and MTZ2 Active frames. The 0.7-1.1 Un trip window and 60 ms response time are unchanged from the lower-voltage variants. It ships one piece per package, matching the rest of the MasterPacT Active MX coil family.
| Range | MasterPacT |
|---|---|
| Device short name | MX |
| Product or component type | Voltage release |
| Device application | Control |
| Range compatibility | MasterPacT MTZ1 Active circuit-breaker, MasterPacT MTZ2 Active circuit-breaker |
| Voltage release type | Opening coil |
| Control type | Standard |
|---|---|
| [Un] voltage power supply | 380...480 V AC 50/60 Hz |
| Threshold tripping voltage | 0.7...1.1 Un on opening |
| Holding power consumption | 4.5 VA |
| Circuit breaker mounting mode | Fixed |
| Maximum response time | 60 ms on opening for MasterPact MTZ1, 60 ms on opening for MasterPact MTZ2, 60 ms on opening for MasterPact MTZ3 |
| Warranty (in months) | 18 |
|---|
| Part number | LV947365 |
|---|---|
| Type designation | MX |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2 cm |
| Package 1 Width | 1 cm |
| Package 1 Length | 2 cm |
| Package 1 Weight | 10 g |
| Shipping weight | 0.01 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of MX is 380–480 V AC.
The tariff (HS) code on file for MX is 853890.
MX ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Source ACB accessories fast with verified OEM parts, lead times, authenticity checks, and stocking strategy to cut downtime on Emax 2 frames. Shop at...
Compare 1600-2500A ACB platforms: ABB Emax 2, Schneider MTZ2, Siemens 3WL2 on breaking capacity, trip units, endurance and lifecycle cost. Shop at Stoklink.
ABB Emax 2 air circuit breaker selection, sizing, trip units, selectivity, and maintenance guide for 630 to 6300 A LV switchgear engineers. Shop at...