Types of Molded Case Circuit Breakers: MCCB Guide for Engineers
Compare MCCB types including thermal-magnetic, electronic trip, motor protection, current-limiting, and DC-rated units for industrial use. Shop at Stoklink.
The Schneider Electric LV426844 is a standard MX shunt trip release for ComPacT NSXm and PowerPact B moulded case circuit breakers, rated 220-240 V AC 50 Hz (also available as 208-240 V AC 60 Hz, 277 V AC 60 Hz or 250 V DC on this same reference). It trips the breaker on command for emergency-off or remote-opening duty once the control voltage exceeds 70% of its rated value, with a response time under 50 ms.
LV426844 suits ComPacT NSXm and PowerPact B breakers wired to 220-240 V AC 50 Hz control circuits; the same body also covers 208-240 V AC 60 Hz, 277 V AC 60 Hz and 250 V DC supplies. For breakers running on 380/415 V AC or 440/480 V AC control circuits, choose the higher-voltage shunt trip variant instead. The one-click spring-terminal body mounts on the breaker's front face, so wiring the emergency-off or remote-opening circuit needs no screw tools and the coil position stays visible for inspection. ComPacT NSXm and PowerPact B accept either one MX or one MN coil, never both at once.
| Range | ComPact |
|---|---|
| Range of Product | ComPacT NSXm |
| Device short name | MX |
| Product or Component Type | Voltage release |
| Device Application | Control |
| Voltage release type | Opening coil, Shunt trip release |
| Control Type | Standard |
| [Uc] control circuit voltage | 220...240 V AC 50 Hz, 208...240 V AC 60 Hz, 277 V AC 60 Hz, 250 V DC |
| Range compatibility | ComPact ComPacT NSXm, ComPact ComPact NSXm, PowerPact PowerPact B |
| Operating threshold | 0.7 Un opening |
|---|---|
| Response time | < 50 ms |
| Control signal type | Impulse, Maintained |
| Impulse duration | >= 20 ms |
| Auxiliary connection terminal | spring |
| Warranty (in months) | 18 |
|---|
| Part number | LV426844 |
|---|---|
| Type designation | MX |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606485413075 |
| Country of origin | FR |
|---|---|
| Shipping weight | 0.059 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of MX is 220–240 V AC.
The tariff (HS) code on file for MX is 853890.
The EAN (GTIN) of MX is 3606485413075.
MX ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Compare MCCB types including thermal-magnetic, electronic trip, motor protection, current-limiting, and DC-rated units for industrial use. Shop at Stoklink.
Select the right MCCB with our engineer checklist covering IEC 60947-2, sizing, breaking capacity, trip units, and derating for industry. Shop at Stoklink.
IEC 60947-2 defines MCCB ratings Icu, Ics, Icw, utilization categories A and B, and type tests for low-voltage circuit breakers up to 1000V. Shop...