Part number
LUCL18BL
Model no
LUCL
332.67 SR On request Dispatch — · From TürkiyeGet a Quote
TeSys Ultra

Schneider Electric LUCL18BL TeSys U Standard Control Unit 4.5-18 A 24 V DC Motor Starter Module

TeSys U magnetic control unit, 4.5-18 A short-circuit protection, 24 V DC coil, for LUB32/LUB38 bases.

Rated current
18 A
Rated operational voltage
24 V DC
Description

About the LUCL

The Schneider Electric LUCL18BL is a TeSys U magnetic control unit that plugs into a LUB32 or LUB38 power base to form a TeSys U starter-controller for 3-phase motors up to 7.5 kW at 400 V. It sets dial-adjustable short-circuit protection from 4.5 to 18 A, tripping at 14.2 x Ir, and runs on a 24 V DC control circuit.

Certifications & Standards

  • CE
  • EAC
  • ATEX
  • IEC 60947-6-2
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1

Selection Notes

The LUCL18BL covers the mid current band of the LUCL lineup for LUB32/LUB38 bases; pick the 1X variant below 1.4 A or the 32/38 A units above 18 A on the same bases. Because this control unit only supplies short-circuit protection and manual reset, it is meant for applications where a connected variable speed drive or soft starter already handles overload protection — pairing it with an unprotected motor leaves no thermal overload coverage. The 24 V DC coil fits PLC or relay outputs already running on 24 V DC control rails; pick the ES or FU coil variants where the control supply is AC.

Specification

Full specification

71 values · Last verified 30 Oct 2026

Main 17

Range TeSys
Range of product TeSys Ultra
Product name TeSys Ultra
Device short name LUCL
Product or component type Magnetic control unit
Device application Motor control, Motor protection
Product specific application Protection of variable speed drive or soft startsoft stop unit
main function available Manual reset, Short-circuit protection
Product compatibility Power base LUB32, Power base LUB38, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B32BL, Reversing contactor breaker LU2B38BL
[Ue] rated operational voltage 690 V AC
Network frequency 40...60 Hz
Load type 3-phase motor - cooling: self-cooled
Utilisation category AC-43, AC-41, AC-44
Motor power kW 7.5 kW at 400...440 V AC 50/60 Hz, 9 kW at 500 V AC 50/60 Hz, 15 kW at 690 V AC 50/60 Hz
rated motor current adjustment range 4.5…18 A
Tripping threshold 14.2 x Ir +/- 20 %
[Uc] control circuit voltage 24 V DC

Complementary 15

Control circuit voltage limits 20...27 V for DC circuit 24 V in operation, 14.5 V for DC circuit 24 V drop-out
Typical current consumption 220 mA at 24 V DC I maximum while closing with LUB32, 220 mA at 24 V DC I maximum while closing with LUB38, 80 mA at 24 V DC I rms sealed with LUB32, 80 mA at 24 V DC I rms sealed with LUB38
Heat dissipation 3 W for control circuit with LUB32, 3 W for control circuit with LUB38
Operating time 35 ms opening with LUB32 for control circuit, 35 ms opening with LUB38 for control circuit, 70 ms closing with LUB32 for control circuit, 70 ms closing with LUB38 for control circuit
Standards EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier
Product certifications CE, EAC, ATEX
[Ui] rated insulation voltage 690 V conforming to IEC 60947-6-2, 600 V conforming to UL 60947-4-1, 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-6-2
Safe separation of circuit 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Fixing mode Plug-in (front face)
Width 45 mm
Height 66 mm
Depth 60 mm
Net weight 0.135 kg
Compatibility code LUCL

Environment 15

IP degree of protection IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1
Protective treatment TH conforming to IEC 60068
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Operating altitude 2000 m
Fire resistance 960 °C parts supporting live components conforming to IEC 60695-2-12, 650 °C conforming to IEC 60695-2-12
Shock resistance 10 gn power poles open conforming to IEC 60068-2-27, 15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance 2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6, 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6
Resistance to electrostatic discharge 8 kV level 3 in open air conforming to IEC 61000-4-2, 8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating shock wave 1 kV serial mode conforming to IEC 60947-6-2, 2 kV common mode conforming to IEC 60947-6-2
Resistance to radiated fields 10 V/m 3 conforming to IEC 61000-4-3
Resistance to fast transients 2 kV class 3 serial link conforming to IEC 61000-4-4, 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Immunity to radioelectric fields 10 V conforming to IEC 61000-4-6
Immunity to microbreaks 3 ms
Immunity to voltage dips 70 % / 500 ms conforming to IEC 61000-4-11
Show all 71 specifications ↓ Show less ↑24 more values in Identification, Contractual warranty, Logistics.

Identification 7

Part number LUCL18BL
Type designation LUCL
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production

Contractual warranty 1

Warranty (in months) 18

Logistics 16

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.500 cm
Package 1 Width 8.000 cm
Package 1 Length 10.300 cm
Package 1 Weight 129.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 23
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 3.242 kg
Shipping weight 0.135 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for LUCL18BL

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CE
  • EAC
  • EN 60947-6-2
  • IEC 60947-6-2
  • UL 60947-4-1
  • with phase barrier
Quick answers

Questions about the LUCL

What is the rated current of LUCL?

The rated current of LUCL is 18 A.

Which supply voltage is LUCL rated for?

The rated operational voltage of LUCL is 24 V DC.

What is the HS code of LUCL for customs?

The tariff (HS) code on file for LUCL is 853650.

Where does LUCL ship from, and how fast?

LUCL ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for motor starters

All guides for motor starters
Reviews

Customer reviews

Series

Schneider Electric TeSys Ultra

Brand
Schneider Electric
Series
TeSys Ultra
332.67 SR On request
Get a Quote
Quote

Get a Quote

LUCL

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LUCL18BL

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart