Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
The Schneider Electric LUA1C20 is a TeSys U auxiliary signalling contact block with a 2 NO contact composition, rated up to 5 A at 250 V AC/DC. It inserts into the dedicated slot of a TeSys U power base and provides fault signalling (SD contact) and ready-position indication (OF contact), both wired as normally-open.
The 2NO composition reports both the open/closed status (OF contact) and the tripping status (SD contact) as normally-open signals, matching PLC input cards or indicator circuits that expect uniform NO logic - choose the 1NO+1NC composition instead where the trip signal needs to be fail-safe (normally-closed).
| Range | TeSys |
|---|---|
| Device short name | LUA1 |
| Product or Component Type | Auxiliary contact |
| Auxiliary contact composition | 2 NO |
|---|---|
| Signalling function | Fault signalling, Indicating rotary knob in ready position |
| [Ue] rated operational voltage | <= 250 V AC, <= 250 V DC |
| [Ui] rated insulation voltage | 250 V CSA, 250 V IEC 60947-5-1, 250 V UL |
| [Ith] conventional free air thermal current | 2.5 A |
| Minimum switching voltage | 17 V |
| minimum switching current | 5 mA |
| Net Weight | 0.07 lb(US) (0.03 kg) |
| Connections - terminals | screw clamp terminals |
| Warranty (in months) | 18 |
|---|
| Part number | LUA1C20 |
|---|---|
| Type designation | LUA1 |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3389110367300 |
| Country of origin | CZ |
|---|---|
| Shipping weight | 0.03 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of LUA1 is 2.5 A.
The rated operational voltage of LUA1 is 250 V AC.
The tariff (HS) code on file for LUA1 is 853650.
The EAN (GTIN) of LUA1 is 3389110367300.
LUA1 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.