Part number
LP1K1210FD
Model no
LP1K
104.66 SR On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric LP1K1210FD TeSys K Contactor 3P 3NO AC-3 12 A 110 V DC Coil 1NO Screw Clamp Contactor

TeSys K contactor, 3P 3NO, 12 A AC-3, 110 V DC coil, 1NO, 5.5 kW at 400 V

Rated current
12 A
Motor power
5.5 kW
Poles
3P
EAN
3389110247909
Description

About the LP1K

The Schneider Electric LP1K1210FD is a TeSys K three-pole contactor rated 12 A AC-3 at up to 440 V, switching motors up to 5.5 kW at 400 V on a 110 V DC coil with one built-in 1NO auxiliary contact. Screw clamp terminals and a 45 mm width keep it compact for DIN-rail panel layouts.

Certifications & Standards

  • CB Scheme
  • CCC
  • UL
  • CSA
  • EAC
  • CE
  • UKCA
  • EN/IEC 60947-4-1
  • EN/IEC 60947-5-1
  • UL 60947-4-1
  • UL 60947-5-1
  • CSA C22.2 No. 60947-4-1
  • CSA C22.2 No. 60947-5-1
  • GB/T 14048.4

Selection Notes

At 12 A AC-3 this is the largest current rating in the LP1K line sampled here, covering 5.5 kW motors at 400 V; step down to the 9 A LP1K0901FD/LP1K0910ED or 6 A LP1K0601FD/LP1K0610FD for smaller motors.

Specification

Full specification

64 values · Last verified 29 Oct 2026

Main 4

Range TeSys
Product or Component Type Contactor
Device short name LP1K
Contactor application Motor control Resistive load

Complementary 39

Utilisation category AC-3 AC-3e AC-1 AC-4
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit <= 690 V AC <= 400 Hz Signalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current 12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit 20 A (at <140 °F (60 °C)) at <= 690 V AC AC-1 for power circuit
Control circuit type DC standard
[Uc] control circuit voltage 110 V DC
Motor power kW 3 kW 220...230 V AC 50/60 Hz AC-3 5.5 kW 380...415 V AC 50/60 Hz AC-3 5.5 kW 440 V AC 50/60 Hz AC-3 4 kW 690 V AC 50/60 Hz AC-3 3 kW 220...230 V AC 50/60 Hz AC-3e 5.5 kW 380...415 V AC 50/60 Hz AC-3e 5.5 kW 440 V AC 50/60 Hz AC-3e 4 kW 690 V AC 50/60 Hz AC-3e 3 kW 220...230 V AC 50/60 Hz AC-4 5.5 kW 380...415 V AC 50/60 Hz AC-4 5.5 kW 440 V AC 50/60 Hz AC-4
Auxiliary contact composition 1 NO
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 140 °F (60 °C)) for power circuit 10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity 144 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current 115 A 122 °F (50 °C) - 1 s for power circuit 105 A 122 °F (50 °C) - 5 s for power circuit 100 A 122 °F (50 °C) - 10 s for power circuit 75 A 122 °F (50 °C) - 30 s for power circuit 55 A 122 °F (50 °C) - 1 min for power circuit 50 A 122 °F (50 °C) - 3 min for power circuit 25 A 122 °F (50 °C) - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14
Insulation resistance > 10 MOhm for signalling circuit
Inrush power in W 3 W 68 °F (20 °C))
Hold-in power consumption in W 3 W 68 °F (20 °C)
Heat dissipation 1.3 W
Control circuit voltage limits Operational: 0.8...1.15 Uc (at = 0.10 Uc (at <122 °F (50 °C))
Connections - terminals Screw clamp terminals 1 0.002...0.006 in2 (1.5...4 mm2)solid screw clamp terminals 1 0.001...0.006 in2 (0.75...4 mm2)flexible without cable end screw clamp terminals 1 0.0005...0.004 in2 (0.34...2.5 mm2)flexible with cable end screw clamp terminals 2 0.002...0.006 in2 (1.5...4 mm2)solid screw clamp terminals 2 0.001...0.006 in2 (0.75...4 mm2)flexible without cable end screw clamp terminals 2 0.0005...0.002 in2 (0.34...1.5 mm2)flexible with cable end Power circuit screw clamp terminals 2 0.002 in2 (1.5 mm2)flexible with cable end
Maximum operating rate 3600 cyc/h
Coil technology Without built-in suppressor module
Auxiliary contacts type Instantaneous 1 NO
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Mounting Support Rail Plate
Tightening torque 7.08...11.5 lbf.in (0.8...1.3 N.m) screw clamp terminals Philips No 2 7.08...11.5 lbf.in (0.8...1.3 N.m) screw clamp terminals flat Ø 6 mm 7.08...11.5 lbf.in (0.8...1.3 N.m) screw clamp terminals pozidriv No 2
Operating time 30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 10 Mcycles
Electrical durability 1.3 Mcycles 12 A AC-3 <= 440 V 1.3 Mcycles 12 A AC-3e <= 440 V 0.3 Mcycles 20 A AC-1 <= 690 V 0.02 Mcycles 72 A AC-4 <= 440 V
Height 2.3 in (58 mm)
Width 1.8 in (45 mm)
Depth 2.2 in (57 mm)
Net Weight 0.496 lb(US) (0.225 kg)

Environment 7

Standards EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4
Product Certifications CB Scheme CCC UL CSA EAC CE UKCA
IP degree of protection IP2X
Ambient air temperature for operation -13...122 °F (-25...50 °C)
Ambient Air Temperature for Storage -58...176 °F (-50...80 °C)
Operating altitude 6561.68 ft (2000 m) without derating
Flame retardance V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
Show all 64 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number LP1K1210FD
Type designation LP1K
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3389110247909

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin ID
Shipping weight 0.225 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 29 Oct 2026

Documents

Documents for LP1K1210FD

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • UL
  • CSA
  • CE
  • UKCA
  • CCC
  • EAC
  • CB Scheme
Quick answers

Questions about the LP1K

What is the rated current of LP1K?

The rated current of LP1K is 12 A.

What motor power is LP1K rated for?

The rated motor power of LP1K is 5.5 kW.

What is the HS code of LP1K for customs?

The tariff (HS) code on file for LP1K is 853650.

What is the EAN of LP1K?

The EAN (GTIN) of LP1K is 3389110247909.

Where does LP1K ship from, and how fast?

LP1K ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Schneider Electric Schneider TeSys K

Brand
Schneider Electric
Series
Schneider TeSys K
Series page →
Series

Other series in Contactors

104.66 SR On request
Get a Quote
Quote

Get a Quote

LP1K

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LP1K1210FD

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart