Part number
LC1D80ED
901.07 SR On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric LC1D80ED TeSys Deca Contactor 3P 3NO AC-3 80 A 48 V DC Coil Contactor

The Schneider Electric LC1D80ED is a 3-pole TeSys Deca Advanced contactor rated 80 A (AC-3) / 37 kW at 400 V, 60 hp at 480 V, with a 48 V DC coil and 1 NO + 1 NC auxiliary contacts.

Poles
3
AC-3 current (400 V)
80 A
Motor power (400 V)
37 kW
Motor power (480 V)
60 hp @ 460/480 V
Coil voltage
48 V DC
Auxiliary contacts
1 NO + 1 NC
EAN
3389110440331
Description

About the LC1D80ED

The Schneider Electric LC1D80ED is a 3-pole TeSys Deca contactor rated 80 A AC-3 at up to 440 V, switching motors up to 37 kW at 400 V. It ships with a 48 V DC coil carrying a built-in transient suppressor module and a 1 NO + 1 NC auxiliary block with a mirror-certified NC contact.

Certifications & Standards

  • CCC
  • UL
  • CB Scheme
  • CSA
  • CE
  • UKCA
  • Marine
  • EAC
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • CSA C22.2 No 14
  • UL 60947-4-1

Selection Notes

The 48 V DC coil with built-in transient suppressor module suits panels powered from a DC control bus or battery backup rather than a transformer tap, and it lengthens the frame depth to 186 mm versus the AC-coil version at this current rating. Pick this DC-coil variant when the control architecture is already 48 V DC; choose an AC-coil sibling in the LC1D range when the panel runs on a standard AC control transformer instead.

Applications

Motor starters up to 37 kW at 400 V in DC-control panels, battery-backed control systems, and installations where 48 V DC logic already drives other field devices.

Applications (manufacturer): Motor control, Resistive load

Specification

Full specification

112 values · Last verified 03 Nov 2026

General 5

Series TeSys Deca Advanced
Contactor size / frame D80
Number of poles 3
Main contact configuration 3 NO
Utilisation categories AC-3 AC-3e AC-1 AC-4

Electrical 9

Rated operational current Ie, AC-3, 400 V 80 A
Rated motor power, AC-3, 400 V 37 kW
Motor power at other voltages, AC-3 22 kW @ 220/230 V · 45 kW @ 415/440 V · 55 kW @ 500 V · 45 kW @ 660/690 V · 45 kW @ 1000 V
Rated operational current, AC-1 (60 °C) 125 A
Conventional free-air thermal current Ith 125 A
Rated motor power, AC-4, 400 V 15 kW
Max. rated operational voltage Ue 1000 V
Rated insulation voltage Ui 1000 V
Rated impulse withstand voltage Uimp 8 kV

Control circuit 4

Rated control supply voltage Uc 48 V
Coil type DC
Coil technology Without built-in suppressor module
Coil holding power 22 W | VA
Show all 54 specifications ↓ Show less ↑36 more values in Identification, Auxiliary contacts, Mechanical, Dimensions and weight, Environmental, North American ratings (UL/CSA), Certifications and standards, Logistics. 58 more as published by Schneider Electric are shown on request.

Identification 11

Part number LC1D80ED
Model code D80
Brand Schneider Electric
Series TeSys Deca Advanced
Family Contactors
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3389110440331
Catalogue number explained LC1 = 3-pole contactor; D = TeSys Deca Advanced range; 80 = 80 A AC-3 rating; ED = coil code (48 V DC)

Auxiliary contacts 4

Built-in auxiliary contacts, NO 1
Built-in auxiliary contacts, NC 1
Auxiliary contacts 1 NO + 1 NC
Mirror contact (IEC 60947-4-1 Annex F) Yes

Mechanical 2

Main circuit connection Box lug / connector
Mounting 35 mm DIN rail, Panel (screw) mounting

Dimensions and weight 4

Width 85 mm
Height 127 mm
Depth 186 mm
Net weight 2.59 kg

Environmental 4

Ambient operating temperature -40 … 60 °C
Degree of protection IP20
Mechanical durability 4000000 cycles
Max. operating frequency, AC-3 3600 cycles/h

North American ratings (UL/CSA) 3

Motor rating (UL/CSA) 30 hp @ 200/208 V · 30 hp @ 230/240 V · 60 hp @ 460/480 V · 60 hp @ 575/600 V · 7.5 hp @ 120 V (1-ph) · 15 hp @ 230/240 V (1-ph)
Short-circuit current rating (SCCR) 100 kA
Max. operating voltage UL/CSA 600 V

Certifications and standards 2

Certifications CB Scheme, UL, CSA, CCC, CE, UKCA, EAC, Marine
Conforming standards CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60335-1, IEC 60335-2-40, IEC 60947-4-1, IEC 60947-5-1, UL 60335-2-40, UL 60947-4-1

Logistics 6

Package dimensions (L × W × H) 158 × 216 × 110 mm
Package weight 2.602 kg
Shipping weight 2.59 kg
Ships from Türkiye
Dispatch —
Stock On request
Additional manufacturer data 58 58 more values as published by Schneider Electric, shown on request.

Additional manufacturer data 58

Range TeSys
Product or Component Type Contactor
Device short name LC1D
Compatibility code LC1D
Protective cover With
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 640 A 104 °F (40 °C) - 10 s for power circuit 990 A 104 °F (40 °C) - 1 s for power circuit 135 A 104 °F (40 °C) - 10 min for power circuit 320 A 104 °F (40 °C) - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole 5.1 W AC-3 12.5 W AC-1 5.1 W AC-3e
Overvoltage category III
Pollution degree 3
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Electrical durability 0.8 Mcycles 125 A AC-1 <= 440 V 1.5 Mcycles 80 A AC-3 <= 440 V 1.5 Mcycles 80 A AC-3e <= 440 V
Control circuit type DC standard
Control circuit voltage limits 0.1...0.3 Uc (-40...158 °F (-40...70 °C)):drop-out DC 0.85...1.1 Uc (-40...131 °F (-40...55 °C)):operational DC 1...1.1 Uc (131...158 °F (55...70 °C)):operational DC
Inrush power in W 22 W 68 °F (20 °C))
Operating time 95...130 ms closing 20...35 ms opening
Time constant 75 ms
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Protective treatment THIEC 60068-2-30
Climatic withstand IACS E10 exposure to damp heat
Operating altitude 0...9842.52 ft (0...3000 m)
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz) Shocks contactor open 8 Gn for 11 ms) Vibrations contactor closed 3 Gn, 5...300 Hz) Shocks contactor closed 10 Gn for 11 ms)
Category US1CTR121252
Discount Schedule CTR1
Returnability No
Unit Type of Package 1 PCE
Nbr. of units in pkg. 1
Unit Type of Package 2 S02
Number of Units in Package 2 2
Package 2 Height 5.9 in (15 cm)
Package 2 Width 11.8 in (30 cm)
Package 2 Length 15.7 in (40 cm)
Package 2 Weight 12.066 lb(US) (5.473 kg)
Total lifecycle Carbon footprint 176 kg CO2 eq.
Carbon footprint of the manufacturing phase [A1 to A3] 17 kg CO2 eq.
Carbon footprint of the distribution phase [A4] 0.3 kg CO2 eq.
Carbon footprint of the installation phase [A5] 0.5 kg CO2 eq.
Carbon footprint of the use phase [B2, B3, B4, B6] 151 kg CO2 eq.
Carbon footprint of the end-of-life phase [C1 to C4] 6 kg CO2 eq.
Environmental Disclosure Product Environmental Profile
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
California proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer and/or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
PVC free Yes
Recyclability potential, in % 76
Circularity Profile No need of specific recycling operations
Take-back No
WEEE Label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

Source: manufacturer data · Last verified: 03 Nov 2026

Documents

Documents for LC1D80ED

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CB Scheme
  • UL
  • CSA
  • CCC
  • CE
  • UKCA
  • EAC
  • Marine
  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60335-1
  • IEC 60335-2-40
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 60335-2-40
  • UL 60947-4-1
Quick answers

Questions about the LC1D80ED

What is the rated current of LC1D80ED?

The rated current of LC1D80ED is 80 A (AC-3, 400 V).

Which supply voltage is LC1D80ED rated for?

The rated operational voltage of LC1D80ED is 1000 V AC.

What motor power is LC1D80ED rated for?

The rated motor power of LC1D80ED is 37 kW (AC-3, 400 V).

Which control voltage does LC1D80ED need?

The control voltage range of LC1D80ED is 48 V DC.

What is the EAN of LC1D80ED?

The EAN (GTIN) of LC1D80ED is 3389110440331.

Where does LC1D80ED ship from, and how fast?

LC1D80ED ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Schneider Electric TeSys Deca Advanced

Brand
Schneider Electric
Series
TeSys Deca Advanced
Series page →
Series

Other series in Contactors

901.07 SR On request
Get a Quote
Quote

Get a Quote

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LC1D80ED

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart