Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
The Schneider Electric LC1D38V7 is a 3-pole TeSys Deca Advanced contactor rated 38 A (AC-3) / 18.5 kW at 400 V, with a 400 V AC 50/60 Hz coil and 1 NO + 1 NC auxiliary contacts.
The Schneider Electric LC1D38V7 is a TeSys Deca 3-pole (3NO) contactor rated 38 A AC-3 at up to 440 V, built for 18.5 kW motors at 400 V. A 400 V 50/60 Hz AC coil lets it connect directly to a three-phase line without a control transformer, and 1NO+1NC mirror-certified auxiliary contacts come standard for feedback wiring.
Running the coil at 400 V removes a control transformer from the bill of materials on panels where the main supply is already 400 V three-phase, which is the main reason to pick the LC1D38V7 over the 110 V F7 or 42 V D7 siblings. It carries the same 38 A AC-3, 18.5 kW at 400 V and 550 A breaking-capacity figures across the whole coil-voltage family. Confirm the control circuit protection is sized for the higher coil inrush before wiring directly to the 400 V bus.
Applications (manufacturer): Resistive load, Motor control
| Series | TeSys Deca Advanced |
|---|---|
| Contactor size / frame | D38 |
| Number of poles | 3 |
| Main contact configuration | 3 NO |
| Utilisation categories | AC-3 AC-3e AC-1 AC-4 |
| Rated operational current Ie, AC-3, 400 V | 38 A |
|---|---|
| Rated motor power, AC-3, 400 V | 18.5 kW |
| Motor power at other voltages, AC-3 | 9 kW @ 220/230 V · 18.5 kW @ 415/440 V · 18.5 kW @ 500 V · 18.5 kW @ 660/690 V |
| Rated operational current, AC-1 (60 °C) | 50 A |
| Conventional free-air thermal current Ith | 50 A |
| Rated motor power, AC-4, 400 V | 7.5 kW |
| Max. rated operational voltage Ue | 690 V |
| Rated insulation voltage Ui | 690 V |
| Rated impulse withstand voltage Uimp | 6 kV |
| Rated control supply voltage Uc | 400 V |
|---|---|
| Coil type | AC |
| Coil frequency | 50/60 Hz |
| Coil technology | Without built-in suppressor module |
| Coil holding power | 7.5 W | VA |
| Part number | LC1D38V7 |
|---|---|
| Model code | D38 |
| Brand | Schneider Electric |
| Series | TeSys Deca Advanced |
| Family | Contactors |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| Catalogue number explained | LC1 = 3-pole contactor; D = TeSys Deca Advanced range; 38 = 38 A AC-3 rating; V7 = coil code (400 V AC 50/60 Hz) |
| Built-in auxiliary contacts, NO | 1 |
|---|---|
| Built-in auxiliary contacts, NC | 1 |
| Auxiliary contacts | 1 NO + 1 NC |
| Mirror contact (IEC 60947-4-1 Annex F) | No |
| Main circuit connection | Screw terminal |
|---|---|
| Mounting | 35 mm DIN rail, Panel (screw) mounting |
| Width | 45 mm |
|---|---|
| Height | 85 mm |
| Depth | 92 mm |
| Net weight | 0.38 kg |
| Ambient operating temperature | -40 … 60 °C |
|---|---|
| Degree of protection | IP20 |
| Mechanical durability | 15000000 cycles |
| Max. operating frequency, AC-3 | 3600 cycles/h |
| Certifications | CB Scheme, UL, CSA, CCC, UKCA, EAC, Marine |
|---|---|
| Conforming standards | CSA C22.2 No 14, CSA C22.2 No 60947-4-1, EN 60947-4-1, EN 60947-5-1, IEC 60335-1, IEC 60335-2-40, IEC 60947-4-1, IEC 60947-5-1, UL 60335-2-40, UL 60947-4-1 |
| Package dimensions (L × W × H) | 111 × 92 × 51 mm |
|---|---|
| Package weight | 0.417 kg |
| Shipping weight | 0.38 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
| Range | TeSys TeSys Deca |
|---|---|
| Product or component type | Contactor |
| Device short name | LC1D |
| Motor power hp | 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 240 V AC 50/60 Hz for 1 phase motors 20 hp at 480 V AC 50/60 Hz for 3 phases motors 25 hp at 600 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Protective cover | With |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 550 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 60 A 40 °C - 10 min for power circuit 430 A 40 °C - 1 s for power circuit 150 A 40 °C - 1 min for power circuit 310 A 40 °C - 10 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 2 mOhm - Ith 50 A 50 Hz for power circuit |
| Power dissipation per pole | 5 W AC-1 3 W AC-3 3 W AC-3e |
| Overvoltage category | III |
| Pollution degree | 3 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Electrical durability | 1.4 Mcycles 50 A AC-1 at Ue <= 440 V 1.4 Mcycles 38 A AC-3 at Ue <= 440 V 1.4 Mcycles 38 A AC-3e at Ue <= 440 V |
| Control circuit type | AC at 50/60 Hz |
| Control circuit voltage limits | 0.3...0.6 Uc (-40...70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40...60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40...60 °C):operational AC 60 Hz 1...1.1 Uc (60...70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C) 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Heat dissipation | 2...3 W at 50/60 Hz |
| Operating time | 4...19 ms opening 12...22 ms closing |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | Conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor closed (15 Gn for 11 ms) Shocks contactor open (8 Gn for 11 ms) |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 20 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 8.610 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 320 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 144.000 kg |
| Total lifecycle Carbon footprint | 174 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 2 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.2 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 171 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.9 kg CO2 eq. |
| Environmental Disclosure | Product Environmental Profile |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | Yes |
| PVC free | Yes |
| Repair | No |
| Recyclability potential, in % | 66 |
| End of life manual availability | End of Life Information |
| Take-back | No |
| WEEE Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Source: manufacturer data · Last verified: 03 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of LC1D38V7 is 38 A (AC-3, 400 V).
The rated operational voltage of LC1D38V7 is 690 V AC.
The rated motor power of LC1D38V7 is 18.5 kW (AC-3, 400 V).
The control voltage range of LC1D38V7 is 400 V AC.
LC1D38V7 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.