Part number
LC1D32KUE
Model no
LC1D
411.35 SR On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric LC1D32KUE TeSys Deca Advanced Contactor 3P 3NO AC-3 32 A 100-250 V AC/DC Coil Contactor

TeSys Deca Advanced 3P contactor, 32A AC-3, 15kW at 400V, 100-250 V AC/DC coil.

Rated current
32 A
Rated operational voltage
100–250–DC V DC
Motor power
15 kW
Poles
3P
EAN
3606480987779
Description

About the LC1D

The Schneider Electric LC1D32KUE is a TeSys Deca Advanced 3-pole (3NO) contactor rated 32 A AC-3 at up to 440 V, switching 15 kW motors at 400 V. A sealed low-consumption 100-250 V AC/DC electronic coil covers a wide control-voltage band from a single reference, and 1NO+1NC mirror-certified auxiliary contacts come built in. Screw clamp terminals handle both power and control wiring.

Certifications & Standards

  • IEC 60947-4-1
  • UL
  • CSA
  • CCC
  • UKCA

Selection Notes

Because the LC1D32KUE coil is sealed for the full 100-250 V AC/DC band, one part number covers 110 V, 230 V AC and most DC control rails without ordering a separate coil variant. It carries 15 kW motors at 400 V AC-3, and the 550 A breaking capacity at 440 V gives margin for coordination with an upstream circuit breaker. Projects needing a lower current in the same frame can step down to the 18 A LC1D Advanced version with the identical mounting footprint.

Specification

Full specification

75 values · Last verified 29 Oct 2026

Main 9

Range of Product TeSys Deca Advanced
Product or Component Type Contactor
Device short name LC1D
Contactor application Resistive load Motor control
Utilisation category AC-3 AC-3e AC-1
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current 32 A (at <140 °F (60 °C)) at <= 440 V AC-3 for power circuit 50 A (at <140 °F (60 °C)) at <= 440 V AC-1 for power circuit 32 A (at <140 °F (60 °C)) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage 100...250 V AC 50/60 Hz 100...250 V DC

Complementary 39

Motor power kW 7.5 kW at 220/230 V AC 50/60 Hz (AC-3) 15 kW at 380/400 V AC 50/60 Hz (AC-3) 15 kW at 415 V AC 50/60 Hz (AC-3) 15 kW at 440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 7.5 kW at 220/230 V AC 50/60 Hz (AC-3e) 15 kW at 380/400 V AC 50/60 Hz (AC-3e) 15 kW at 415 V AC 50/60 Hz (AC-3e) 15 kW at 440 V AC 50/60 Hz (AC-3e) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating 2 hp at 115 V AC 50/60 Hz for 1 phase motors 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors 20 hp at 460/480 V AC 50/60 Hz for 3 phase motors 25 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit 50 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 550 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit 60 A 104 °F (40 °C) - 10 min for power circuit 138 A 104 °F (40 °C) - 1 min for power circuit 260 A 104 °F (40 °C) - 10 s for power circuit 430 A 104 °F (40 °C) - 1 s for power circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2 mOhm - Ith 50 A 50 Hz for power circuit
Power dissipation per pole 2 W AC-3 5 W AC-1 2 W AC-3e
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 15 Mcycles
Electrical durability 2.1 Mcycles 29 A AC-3 <= 440 V 0.9 Mcycles 50 A AC-1 <= 440 V 2.1 Mcycles 29 A AC-3e <= 440 V
Control circuit type AC/DC 50/60 Hz AC/DC electronic
Coil technology Built-in bidirectional peak limiting
Control circuit voltage limits <= 0.1 Uc (-40...158 °F (-40...70 °C)):drop-out AC/DC 0.85...1.1 Uc (-40...140 °F (-40...60 °C)):operational AC/DC 1...1.1 Uc (140...158 °F (60...70 °C)):operational AC/DC
Inrush power in VA 25 VA 50/60 Hz (at 68 °F (20 °C))
Inrush power in W 18 W 68 °F (20 °C))
Hold-in power consumption in VA 1.6 VA 50/60 Hz (at 68 °F (20 °C))
Hold-in power consumption in W 1.1 W 68 °F (20 °C)
Heat dissipation 1.1 W at 50/60 Hz
Operating time 45...55 ms closing 20...90 ms opening
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 1 0.002...0.006 in2 (1...4 mm2) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in2 (1...4 mm2) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.006 in2 (1...4 mm2) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 0.002...0.004 in2 (1...2.5 mm2) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in2 (1...4 mm2) - cable stiffness: solid Control circuit: screw clamp terminals 2 0.002...0.006 in2 (1...4 mm2) - cable stiffness: solid Power circuit: screw clamp terminals 1 0.004...0.02 in2 (2.5...10 mm2) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 0.004...0.02 in2 (2.5...10 mm2) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 0.002...0.02 in2 (1...10 mm2) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 0.002...0.009 in2 (1.5...6 mm2) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 0.002...0.02 in2 (1.5...10 mm2) - cable stiffness: solid Power circuit: screw clamp terminals 2 0.004...0.02 in2 (2.5...10 mm2) - cable stiffness: solid
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals Philips No 2 Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2 M4 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 M3.5
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Mounting Support Plate Rail

Environment 13

Standards EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC 60335-1
Product Certifications CCC CSA EAC UL KC DNV-GL LROS (Lloyds register of shipping) UKCA
IP degree of protection IP20 front face IEC 60529
Climatic withstand IACS E10 exposure to damp heat IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating
Operating altitude 0...9842.52 ft (0...3000 m)
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz) Vibrations contactor closed 4 Gn, 5...300 Hz) Shocks contactor closed 15 Gn for 11 ms) Shocks contactor open 8 Gn for 11 ms)
Height 3.3 in (85 mm)
Width 1.8 in (45 mm)
Depth 3.6 in (92 mm)
Net Weight 0.966 lb(US) (0.438 kg)
Show all 75 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number LC1D32KUE
Type designation LC1D
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3606480987779

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin FR
Shipping weight 0.438 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 29 Oct 2026

Documents

Documents for LC1D32KUE

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • UL
  • CSA
  • UKCA
  • CCC
  • EAC
Quick answers

Questions about the LC1D

What is the rated current of LC1D?

The rated current of LC1D is 32 A.

Which supply voltage is LC1D rated for?

The rated operational voltage of LC1D is 100–250–DC V DC.

What motor power is LC1D rated for?

The rated motor power of LC1D is 15 kW.

What is the HS code of LC1D for customs?

The tariff (HS) code on file for LC1D is 853650.

What is the EAN of LC1D?

The EAN (GTIN) of LC1D is 3606480987779.

Where does LC1D ship from, and how fast?

LC1D ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Schneider Electric Schneider TeSys Deca

Brand
Schneider Electric
Series
Schneider TeSys Deca
Series page →
Series

Other series in Contactors

411.35 SR On request
Get a Quote
Quote

Get a Quote

LC1D

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LC1D32KUE

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart