Part number
LC1D12V7
104.21 SR On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric LC1D12V7 TeSys Deca Contactor 3P 3NO AC-3 12 A 400 V AC Coil Contactor

The Schneider Electric LC1D12V7 is a 3-pole TeSys Deca Advanced contactor rated 12 A (AC-3) / 5.5 kW at 400 V, with a 400 V AC 50/60 Hz coil and 1 NO + 1 NC auxiliary contacts.

Poles
3
AC-3 current (400 V)
12 A
Motor power (400 V)
5.5 kW
Coil voltage
400 V AC
Auxiliary contacts
1 NO + 1 NC
Description

About the LC1D12V7

Rated 12 A AC-3 at up to 440 V, the Schneider Electric LC1D12V7 is a TeSys Deca 3-pole (3NO) contactor that switches 5.5 kW motors at 400 V. It takes a 400 V 50/60 Hz AC coil, which lets it connect directly to a three-phase supply line without a separate control transformer, and ships with 1NO+1NC mirror-certified auxiliary contacts.

Certifications & Standards

  • IEC 60947-4-1
  • UL
  • CSA
  • CCC
  • Marine

Selection Notes

The 400 V AC coil on the LC1D12V7 suits panels that run their control circuit straight off a three-phase 400 V feeder, avoiding a step-down control transformer entirely. Inrush draws 70 VA at pickup before settling to a lower holding value, so size any shared control transformer for the inrush figure if several contactors close together. For lower control voltages in the same frame, the 24 V and 230 V AC LC1D coil variants apply.

Applications (manufacturer): Motor control, Resistive load

Specification

Full specification

111 values · Last verified 03 Nov 2026

General 5

Series TeSys Deca Advanced
Contactor size / frame D12
Number of poles 3
Main contact configuration 3 NO
Utilisation categories AC-3 AC-3e AC-1 AC-4

Electrical 9

Rated operational current Ie, AC-3, 400 V 12 A
Rated motor power, AC-3, 400 V 5.5 kW
Motor power at other voltages, AC-3 3 kW @ 220/230 V · 5.5 kW @ 415/440 V · 7.5 kW @ 500 V · 7.5 kW @ 660/690 V
Rated operational current, AC-1 (60 °C) 25 A
Conventional free-air thermal current Ith 25 A
Rated motor power, AC-4, 400 V 3.7 kW
Max. rated operational voltage Ue 690 V
Rated insulation voltage Ui 690 V
Rated impulse withstand voltage Uimp 6 kV

Control circuit 5

Rated control supply voltage Uc 400 V
Coil type AC
Coil frequency 50/60 Hz
Coil technology Without built-in suppressor module
Coil holding power 7.5 W | VA
Show all 51 specifications ↓ Show less ↑32 more values in Identification, Auxiliary contacts, Mechanical, Dimensions and weight, Environmental, Certifications and standards, Logistics. 60 more as published by Schneider Electric are shown on request.

Identification 10

Part number LC1D12V7
Model code D12
Brand Schneider Electric
Series TeSys Deca Advanced
Family Contactors
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
Catalogue number explained LC1 = 3-pole contactor; D = TeSys Deca Advanced range; 12 = 12 A AC-3 rating; V7 = coil code (400 V AC 50/60 Hz)

Auxiliary contacts 4

Built-in auxiliary contacts, NO 1
Built-in auxiliary contacts, NC 1
Auxiliary contacts 1 NO + 1 NC
Mirror contact (IEC 60947-4-1 Annex F) No

Mechanical 2

Main circuit connection Screw terminal
Mounting 35 mm DIN rail, Panel (screw) mounting

Dimensions and weight 4

Width 45 mm
Height 77 mm
Depth 86 mm
Net weight 0.325 kg

Environmental 4

Ambient operating temperature -40 … 60 °C
Degree of protection IP20
Mechanical durability 15000000 cycles
Max. operating frequency, AC-3 3600 cycles/h

Certifications and standards 2

Certifications CB Scheme, UL, CSA, CCC, UKCA, EAC, Marine
Conforming standards CSA C22.2 No 14, CSA C22.2 No 60947-4-1, EN 60947-4-1, EN 60947-5-1, IEC 60335-1, IEC 60335-2-40, IEC 60947-4-1, IEC 60947-5-1, UL 60335-2-40, UL 60947-4-1

Logistics 6

Package dimensions (L × W × H) 115 × 94 × 53 mm
Package weight 0.352 kg
Shipping weight 0.325 kg
Ships from Türkiye
Dispatch —
Stock On request
Additional manufacturer data 60 60 more values as published by Schneider Electric, shown on request.

Additional manufacturer data 60

Product or component type Contactor
Device short name LC1D
Motor power hp 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Protective cover With
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 105 A 40 °C - 10 s for power circuit 210 A 40 °C - 1 s for power circuit 30 A 40 °C - 10 min for power circuit 61 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole 0.36 W AC-3 1.56 W AC-1 0.36 W AC-3e
Overvoltage category III
Pollution degree 3
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Electrical durability 2 Mcycles 12 A AC-3 at Ue <= 440 V 0.8 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 12 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz standard
Control circuit voltage limits 0.3...0.6 Uc (-40...70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40...60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40...60 °C):operational AC 60 Hz 1...1.1 Uc (60...70 °C):operational AC 50/60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C) 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Heat dissipation 2...3 W at 50/60 Hz
Operating time 12...22 ms closing 4...19 ms opening
Tightening torque Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand Conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor open (10 Gn for 11 ms) Shocks contactor closed (15 Gn for 11 ms)
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Unit Type of Package 2 S02
Number of Units in Package 2 20
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 7.342 kg
Unit Type of Package 3 P06
Number of Units in Package 3 320
Package 3 Height 75 cm
Package 3 Width 60 cm
Package 3 Length 80 cm
Package 3 Weight 125.47 kg
Total lifecycle Carbon footprint 23 kg CO2 eq.
Carbon footprint of the manufacturing phase [A1 to A3] 1 kg CO2 eq.
Carbon footprint of the distribution phase [A4] 0.2 kg CO2 eq.
Carbon footprint of the installation phase [A5] 0.1 kg CO2 eq.
Carbon footprint of the use phase [B2, B3, B4, B6] 22 kg CO2 eq.
Environmental Disclosure Product Environmental Profile
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
PVC free Yes
Repair No
Recyclability potential, in % 66
End of life manual availability End of Life Information
Take-back No
WEEE Label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Source: manufacturer data · Last verified: 03 Nov 2026

Documents

Documents for LC1D12V7

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CB Scheme
  • UL
  • CSA
  • CCC
  • UKCA
  • EAC
  • Marine
  • CSA C22.2 No 14
  • CSA C22.2 No 60947-4-1
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60335-1
  • IEC 60335-2-40
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 60335-2-40
  • UL 60947-4-1
Quick answers

Questions about the LC1D12V7

What is the rated current of LC1D12V7?

The rated current of LC1D12V7 is 12 A (AC-3, 400 V).

Which supply voltage is LC1D12V7 rated for?

The rated operational voltage of LC1D12V7 is 690 V AC.

What motor power is LC1D12V7 rated for?

The rated motor power of LC1D12V7 is 5.5 kW (AC-3, 400 V).

Which control voltage does LC1D12V7 need?

The control voltage range of LC1D12V7 is 400 V AC.

Where does LC1D12V7 ship from, and how fast?

LC1D12V7 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Schneider Electric TeSys Deca Advanced

Brand
Schneider Electric
Series
TeSys Deca Advanced
Series page →
Series

Other series in Contactors

104.21 SR On request
Get a Quote
Quote

Get a Quote

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LC1D12V7

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart