Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
The Schneider Electric LAD9150RFB1 is a retrofit base plate that lets a single 115 A to 150 A TeSys Deca Advanced contactor be installed into an existing panel built for a TeSys Deca LC1D115 or LC1D150 contactor, 3 poles. It matches the mounting footprint and power connections of the legacy contactor so the enclosure does not need rework. It operates from -40°C to 70°C and up to 3000 m altitude without derating.
Use the LAD9150RFB1 when replacing a single LC1D115 or LC1D150 TeSys Deca contactor with a TeSys Deca Advanced unit of the same 115-150 A frame, without re-drilling the panel. For replacing a horizontally mounted pair of contactors instead of a single unit, use the two-piece LAD9150RFB2 base.
| Range of Product | TeSys Deca |
|---|---|
| Range | TeSys |
| Device short name | LAD9 |
| Product or Component Type | Plate |
| Product Compatibility | LC1D115, LC1D150 |
| Net Weight | 0.40 lb(US) (0.18 kg) |
|---|---|
| Quantity per Set | 1 |
| Ambient Air Temperature for Operation | -40…158 °F (-40…70 °C) |
|---|---|
| Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) |
| Part number | LAD9150RFB1 |
|---|---|
| Type designation | LAD9 |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606487159414 |
| Warranty (in months) | 18 |
|---|
| Country of origin | CN |
|---|---|
| Shipping weight | 0.18 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for LAD9 is 853690.
The EAN (GTIN) of LAD9 is 3606487159414.
LAD9 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.