Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
The Schneider Electric LA9G971 is a TeSys Giga mechanical interlock pairing an LC1G265-500 contactor with an LC1G115-225 contactor, built for star-delta assemblies without electrical interlocking. It provides IP20 protection and operates across -25 to 60 °C up to 3000 m altitude without derating.
The LA9G971 interlocks a mixed-frame pair, an LC1G265-500 unit with an LC1G115-225 unit, for a star-delta starter where the star contactor is a smaller frame than the line and delta contactors. Where all contactors being interlocked are the same frame, the LA9G970 interlock is the correct part instead.
| Range | TeSys |
|---|---|
| Device short name | LA9G |
| Product or Component Type | Mechanical interlock |
| Accessory / separate part category | Interlocking accessory |
| Interlocking type | Mechanical |
| Range Compatibility | TeSys Giga |
| Product Compatibility | LC1G115...225, LC1G265...500, LC1G205...245, LC1G300...475 |
| Poles description | 3P |
| Electrical circuit type | Star-delta |
| Height | 2.0 in (50 mm) |
|---|---|
| Width | 3.1 in (80 mm) |
| Depth | 5.5 in (140 mm) |
| Net Weight | 0.33 lb(US) (0.15 kg) |
| Pollution degree | 3 IEC 60947-1 |
|---|---|
| Operating altitude | 9842.52 ft (3000 m) without derating, 5000 m with derating factor |
| Standards | EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB/T 14048.4 |
| Part number | LA9G971 |
|---|---|
| Type designation | LA9G |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606481916075 |
| Warranty (in months) | 18 |
|---|
| Country of origin | CN |
|---|---|
| Shipping weight | 0.15 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for LA9G is 853690.
The EAN (GTIN) of LA9G is 3606481916075.
LA9G ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.