- Part number
- K1D002ULH
- UL
- CSA
Schneider Electric K1D002ULH Harmony K K1 12A 2P 45° Cam Changeover Switch
Harmony K1 cam changeover switch, 2-pole, 12 A Ith, 45 degree switching angle, IP40, screw mounting.
Description
About the K1D002ULH
About the K1D002ULH
The Schneider Electric K1D002ULH is a Harmony K1 cam changeover switch with two poles, a 45-degree switching angle, and a 12 A conventional free air thermal current (Ith). Front-mounted with a 45 x 45 mm plate, screw-clamp terminals, and a metallic 2-0-1 legend, it handles AC-3 motor loads up to 1.5 kW at 400 V within an IP40 enclosure.
Certifications & Standards
- CSA
- UL
- IEC 60947-3
- IEC 60947-5-1
- CENELEC EN 50013
Selection Notes
The 2-pole changeover configuration switches a single-phase circuit between two sources or directions through a 45-degree throw, using the metallic 2-0-1 legend to mark both positions plus off. Choose the 3-pole or 4-pole K2 changeover switches when the circuit is three-phase; this K1 body is sized for the lighter 12 A Ith / 10 A Ithe duty rather than direct three-phase motor reversing at full load. The 10 kA short-circuit withstand behind a 16 A gG fuse sets the upstream fuse protection needed ahead of the switch.
Specification
Full specification
Main 16
| Range of product | Harmony K |
|---|---|
| Product or component type | Complete cam switch |
| Component name | K1 |
| [Ith] conventional free air thermal current | 12 A |
| Product mounting | Front mounting |
| fixing mode | Multifixing |
| Cam switch head type | With front plate 45 x 45 mm |
| Type of operator | Black handle, length = 35 mm |
| Rotary handle padlocking | Without |
| Presentation of legend | With metallic legend, 2 - 0 - 1 black marking |
| Cam switch function | Changeover switch |
| Return | Without |
| Off position | With Off position |
| Poles description | 2P |
| Switching positions | Left: 0° - 315°, Right: 0° - 45° |
| IP degree of protection | IP40 conforming to IEC 60529 |
Complementary 18
| Switching angle | 45 ° |
|---|---|
| [Ui] rated insulation voltage | 690 V (pollution degree 3) conforming to IEC 60947-1 |
| [Ithe] conventional enclosed thermal current | 10 A |
| Rated operational power in W | 10500 W AC-21, 500...660 V 3 phases conforming to IEC 947-3, 1100 W AC-3, 230 V 3 phases conforming to IEC 947-3, 1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3, 1500 W AC-3, 400 V 1 phase conforming to IEC 947-3, 1500 W AC-3, 400 V 3 phases conforming to IEC 947-3, 1500 W AC-3, 500 V 3 phases conforming to IEC 947-3, 1500 W AC-3, 690 V 3 phases conforming to IEC 947-3, 2200 W AC-23A, 400 V 3 phases conforming to IEC 947-3, 2200 W AC-23A, 500 V 3 phases conforming to IEC 947-3, 2200 W AC-23A, 690 V 3 phases conforming to IEC 947-3, 4800 W AC-21, 230 V 3 phases conforming to IEC 947-3, 600 W AC-3, 230 V 1 phase conforming to IEC 947-3, 8300 W AC-21, 400 V 3 phases conforming to IEC 947-3 |
| [Ie] rated operational current AC | 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3, 2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3, 2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3, 3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3, 3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3, 4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3, 4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3, 5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3, 1 A at 500 V AC-15 conforming to IEC 947-5-1, 2 A at 400 V AC-15 conforming to IEC 947-5-1, 3 A at 230 V AC-15 conforming to IEC 947-5-1 |
| Electrical durability | 1000000 cycles AC-15, 1000000 cycles AC-21, 500000 cycles AC-23, 500000 cycles AC-3 |
| Maximum operating rate | 2.5 cyc/mn AC-21, 2.5 cyc/mn AC-23, 2.5 cyc/mn AC-3, 8.333 cyc/mn AC-15 |
| Short-circuit current | 10000 A |
| Short-circuit protection | 16 A cartridge fuse, type gG |
| [Uimp] rated impulse withstand voltage | 4 kV in isolating function, 6 kV conforming to IEC 947-1 |
| Contact operation | Slow-break |
| positive opening | With |
| Electrical connection | Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm², Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm² |
| Mechanical durability | 1000000 cycles |
| CAD overall width | 45 mm |
| CAD overall height | 45 mm |
| CAD overall depth | 87 mm |
| Net weight | 0.14 kg |
Environment 8
| Standards | IEC 60947-3 for power circuit, IEC 60947-5-1 for control circuit, CENELEC EN 50013 |
|---|---|
| Product certifications | CSA 240 V 3 hp 3 phases 2 pole(s), UL 240 V 0.33 hp 1 phase 2 pole(s), CSA 240 V 1 hp 1 phase, UL 240 V 1 hp 3 phases |
| Protective treatment | TC |
| Ambient air temperature for operation | -25…55 °C |
| Ambient air temperature for storage | -40…70 °C |
| Shock resistance | 30 gn conforming to IEC 68-2-27 |
| Vibration resistance | 5 gn conforming to IEC 68-2-6 (f = 10…150 Hz) |
| Electrical shock protection class | Class II conforming to IEC 536, Class II |
Show all 65 specifications ↓ Show less ↑23 more values in Identification, Contractual warranty, Logistics.
Identification 6
| Part number | K1D002ULH |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
Contractual warranty 1
| Warranty (in months) | 18 |
|---|
Logistics 16
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.500 cm |
| Package 1 Width | 6.500 cm |
| Package 1 Length | 11.000 cm |
| Package 1 Weight | 155.000 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 15 cm |
| Package 2 Width | 15 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 1.683 kg |
| Shipping weight | 0.14 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
Documents
Documents for K1D002ULH
No documents are on file for this part yet.
Ask us for the datasheet
Certifications
Certifications and standards
- UL
- CSA
- IEC 60947-3 for power circuit
- IEC 60947-5-1 for control circuit
- CENELEC EN 50013
Quick answers
Questions about the K1D002ULH
What is the HS code of K1D002ULH for customs?
The tariff (HS) code on file for K1D002ULH is 853650.
Where does K1D002ULH ship from, and how fast?
K1D002ULH ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Reviews
Customer reviews
Series
Schneider Electric Harmony K
- Brand
- Schneider Electric
- Series
- Harmony K