- Part number
- K1B002QLH
- UL
- CSA
Schneider Electric K1B002QLH Harmony K K1 1-Pole 12A 45deg Cam Stepping Switch
Harmony K1 cam stepping switch, 1 pole, 12 A, 45° angle, 2 steps plus off position, IP40.
Description
About the K1B002QLH
About the K1B002QLH
The Schneider Electric K1B002QLH is a Harmony K1 cam stepping switch with a single pole, a 45° switching angle, and a 12 A conventional free-air thermal current (Ith). It has two steps plus an off position, uses a black handle with a 0-1-2 metallic legend, and mounts to a front panel via multifixing for local two-step or two-source selection.
Certifications & Standards
- CSA
- UL
- CSA
- UL
- IEC 60947-3
- IEC 60947-5-1
- CENELEC EN 50013
Selection Notes
The K1B002QLH's 0-1-2 stepping function with an off position suits two-step selection or dual-source changeover panels where an operator needs a visible off state between steps. Its single-pole, 45° switching angle and 12 A Ith rating fit small control or signal circuits rather than direct motor switching — at 400 V AC-3 the rated operational current drops to 3.3 A, so size it for pilot or auxiliary circuits, not the main power feed. Multifixing mounting lets it drop into a standard 45 x 45 mm cutout alongside other Harmony K series switches on the same panel.
Applications
Used as a manual selector or stepping switch on control-panel doors for two-speed selection, dual-source changeover, or sequence-step control in machine-building and panel-shop applications.
Specification
Full specification
Main 16
| Range of product | Harmony K |
|---|---|
| Product or component type | Complete cam switch |
| Component name | K1 |
| [Ith] conventional free air thermal current | 12 A |
| Mounting location | Front |
| fixing mode | Multifixing |
| Cam switch head type | With front plate 45 x 45 mm |
| Type of operator | Black handle, length = 35 mm |
| Rotary handle padlocking | Without |
| Presentation of legend | With metallic legend, 0 - 1 - 2 black marking |
| Cam switch function | Stepping switch |
| Return | Without |
| Off position | With Off position |
| Poles description | 1P |
| Switching positions | Right: 0° - 45° - 90° |
| IP degree of protection | IP40 conforming to IEC 60529 |
Complementary 19
| Number of steps | 2 |
|---|---|
| Switching angle | 45 ° |
| [Ui] rated insulation voltage | 690 V (pollution degree 3) conforming to IEC 60947-1 |
| [Ithe] conventional enclosed thermal current | 10 A |
| Rated operational power in W | 10500 W AC-21, 500...660 V 3 phases conforming to IEC 947-3, 1100 W AC-3, 230 V 3 phases conforming to IEC 947-3, 1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3, 1500 W AC-3, 400 V 1 phase conforming to IEC 947-3, 1500 W AC-3, 400 V 3 phases conforming to IEC 947-3, 1500 W AC-3, 500 V 3 phases conforming to IEC 947-3, 1500 W AC-3, 690 V 3 phases conforming to IEC 947-3, 2200 W AC-23A, 400 V 3 phases conforming to IEC 947-3, 2200 W AC-23A, 500 V 3 phases conforming to IEC 947-3, 2200 W AC-23A, 690 V 3 phases conforming to IEC 947-3, 4800 W AC-21, 230 V 3 phases conforming to IEC 947-3, 600 W AC-3, 230 V 1 phase conforming to IEC 947-3, 8300 W AC-21, 400 V 3 phases conforming to IEC 947-3 |
| [Ie] rated operational current AC | 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3, 2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3, 2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3, 3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3, 3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3, 4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3, 4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3, 5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3, 1 A at 500 V AC-15 conforming to IEC 947-5-1, 2 A at 400 V AC-15 conforming to IEC 947-5-1, 3 A at 230 V AC-15 conforming to IEC 947-5-1 |
| Electrical durability | 1000000 cycles AC-15, 1000000 cycles AC-21, 500000 cycles AC-23, 500000 cycles AC-3 |
| Maximum operating rate | 2.5 cyc/mn AC-21, 2.5 cyc/mn AC-23, 2.5 cyc/mn AC-3, 8.333 cyc/mn AC-15 |
| Short-circuit current | 10000 A |
| Short-circuit protection | 16 A cartridge fuse, type gG |
| [Uimp] rated impulse withstand voltage | 4 kV in isolating function, 6 kV conforming to IEC 947-1 |
| Contact operation | Slow-break |
| positive opening | With |
| Electrical connection | Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm², Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm² |
| Mechanical durability | 1000000 cycles |
| CAD overall width | 45 mm |
| CAD overall height | 45 mm |
| CAD overall depth | 77 mm |
| Net weight | 0.115 kg |
Environment 8
| Standards | IEC 60947-3 for power circuit, IEC 60947-5-1 for control circuit, CENELEC EN 50013 |
|---|---|
| Product certifications | CSA 240 V 3 hp 3 phases 2 -pole(s), UL 240 V 0.33 hp 1 phase 2 -pole(s), CSA 240 V 1 hp 1 phase, UL 240 V 1 hp 3 phases |
| Protective treatment | TC |
| Ambient air temperature for operation | -25…55 °C |
| Ambient air temperature for storage | -40…70 °C |
| Shock resistance | 30 gn conforming to IEC 68-2-27 |
| Vibration resistance | 5 gn conforming to IEC 68-2-6 (f = 10…150 Hz) |
| Overvoltage category | Class II conforming to IEC 536, Class II conforming to NF C 20-030 |
Show all 72 specifications ↓ Show less ↑29 more values in Identification, Contractual warranty, Logistics.
Identification 6
| Part number | K1B002QLH |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
Contractual warranty 1
| Warranty (in months) | 18 |
|---|
Logistics 22
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.500 cm |
| Package 1 Width | 6.500 cm |
| Package 1 Length | 11.000 cm |
| Package 1 Weight | 133.000 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 15 cm |
| Package 2 Width | 15 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 1.481 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 320 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 60.000 cm |
| Package 3 Weight | 55.392 kg |
| Shipping weight | 0.115 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
Documents
Documents for K1B002QLH
No documents are on file for this part yet.
Ask us for the datasheet
Certifications
Certifications and standards
- UL
- CSA
- IEC 60947-3 for power circuit
- IEC 60947-5-1 for control circuit
- CENELEC EN 50013
Quick answers
Questions about the K1B002QLH
What is the HS code of K1B002QLH for customs?
The tariff (HS) code on file for K1B002QLH is 853650.
Where does K1B002QLH ship from, and how fast?
K1B002QLH ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Reviews
Customer reviews
Series
Schneider Electric Harmony K
- Brand
- Schneider Electric
- Series