Part number
GV4PE02S
Model no
GV4PE
2,332.43 SR On request Dispatch — · From TürkiyeGet a Quote
TeSys GV4

Schneider Electric GV4PE02S TeSys GV4 3P 2 A 100 kA Thermal-Magnetic Motor Protection Circuit Breaker (MPCB)

GV4 motor circuit breaker, 3P 2 A, Icu 100 kA at 400 V

Rated current
2 A
Rated operational voltage
690 V AC
Motor power
0.25–0.75 kW
EAN
3606481310552
Description

About the GV4PE

The Schneider Electric GV4PE02S is a 3P TeSys GV4 motor circuit breaker rated 2 A, with a breaking capacity of 100 kA at 400/415 V for protecting three-phase motors from 0.25-0.75 kW at 400 V. It combines thermal-magnetic protection with fixed-pickup short-time delay, phase-unbalance and ground-fault protection. The breaker is operated by a toggle and terminates on screw connectors.

Certifications & Standards

  • IEC
  • UL
  • CSA
  • CCC
  • EAC
  • ATEX
  • EU-RO MR
  • EN/IEC 60947-2
  • EN/IEC 60947-4-1
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1

Selection Notes

The S suffix marks the 100 kA Icu breaking-capacity class at 400/415 V. Pick a higher class over the base B (25 kA) version when prospective short-circuit current at the installation point exceeds the lower frame's rating, so the breaker clears the fault on its own without an upstream current-limiting device. The 2 A rated current and 0.25-0.75 kW motor power band set this unit apart from the adjacent frame sizes in the GV4 line.

Specification

Full specification

58 values · Last verified 30 Oct 2026

Main 7

Range TeSys Deca
Range of Product TeSys GV4
Device short name GV4PE
Product name TeSys GV4
Product or Component Type Motor circuit breaker
Device Application Motor protection
Trip unit technology Electronic, Thermal-magnetic

Complementary 27

Poles description 3P
Utilisation category Category A IEC 60947-2, AC-3 IEC 60947-4-1
Operating position Any position
Motor power kW 0.25 kW 400...415 V AC 50/60 Hz, 0.37 kW 400...415 V AC 50/60 Hz, 0.55 kW 400...415 V AC 50/60 Hz, 0.75 kW 400...415 V AC 50/60 Hz, 0.37 kW 500 V AC 50/60 Hz, 0.55 kW 500 V AC 50/60 Hz, 0.75 kW 500 V AC 50/60 Hz, 1.1 kW 500 V AC 50/60 Hz, 0.55 kW 660...690 V AC 50/60 Hz, 0.75 kW 660...690 V AC 50/60 Hz, 1.1 kW 660...690 V AC 50/60 Hz, 1.5 kW 660...690 V AC 50/60 Hz
Breaking capacity 120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2, 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2, 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2, 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2, 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2, 100 kA 208Y/120 V AC 50/60 Hz UL 60947, 100 kA 240 V AC 50/60 Hz UL 60947, 65 kA 480Y/277 V AC 50/60 Hz UL 60947, 10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2, 25 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type Toggle
Line Rated Current 2 A
Magnetic tripping current 34 A
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current 115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Power dissipation per pole 4.6 W
Mechanical durability 40000 cycles
Electrical durability 5000 cycles AC-3 415 V opening, 5000 cycles AC-3 415 V closing
maximum operating rate 25 cyc/h
Rated duty Continuous IEC 60947-4-1
Connections - terminals EverLink BTR screw connectors (top): 1 cable(s) 0.002…0.1 in² (1.5…70 mm²) - solid, EverLink BTR screw connectors (top): 1 cable(s) 0.002…0.08 in² (1.5…50 mm²) - flexible, EverLink BTR screw connectors (bottom): 1 cable(s) 0.004…0.1 in² (2.5…95 mm²) - solid, EverLink BTR screw connectors (bottom): 1 cable(s) 0.004…0.1 in² (2.5…70 mm²) - flexible
Tightening torque 79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²), 44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²)
Mechanical robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6, Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6, Shocks 15 gn 11 ms IEC 60068-2-27
Phase failure sensitivity Yes IEC 60947-4-1
Height 6.1 in (155 mm)
Width 3.2 in (81 mm)
Depth 4.6 in (116 mm)
Net Weight 3.20 lb(US) (1.45 kg)
color Gray RAL 7016)
Suitability for isolation Yes IEC 60947-1

Environment 10

Standards CSA C22.2 No 60947-4-1, UL 60947-4-1, EN/IEC 60947-4-1, EN/IEC 60947-2
Product Certifications IEC, UL, CSA, CCC, EAC, ATEX, EU-RO MR
Climatic withstand IACS E10
IK degree of protection IK07 IEC 62262
Pollution degree 3
IP degree of protection IP40 IEC 60529
Ambient Air Temperature for Storage -58…185 °F (-50…85 °C)
Fire resistance 1760 °F (960 °C) IEC 60695-2-11
Operating altitude 5000 m
Ambient air temperature for operation -13…158 °F (-25…70 °C)
Show all 58 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number GV4PE02S
Type designation GV4PE
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3606481310552

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin PL
Shipping weight 1.45 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for GV4PE02S

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • UL
  • CSA
  • CCC
  • EAC
  • CSA C22.2 No 60947-4-1
  • UL 60947-4-1
  • EN/IEC 60947-4-1
  • EN/IEC 60947-2
Quick answers

Questions about the GV4PE

What is the rated current of GV4PE?

The rated current of GV4PE is 2 A.

Which supply voltage is GV4PE rated for?

The rated operational voltage of GV4PE is 690 V AC.

What motor power is GV4PE rated for?

The rated motor power of GV4PE is 0.25–0.75 kW.

What is the HS code of GV4PE for customs?

The tariff (HS) code on file for GV4PE is 853620.

What is the EAN of GV4PE?

The EAN (GTIN) of GV4PE is 3606481310552.

Where does GV4PE ship from, and how fast?

GV4PE ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for MPCB

All guides for MPCB
Reviews

Customer reviews

Series

Schneider Electric TeSys GV4

Brand
Schneider Electric
Series
TeSys GV4
2,332.43 SR On request
Get a Quote
Quote

Get a Quote

GV4PE

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · GV4PE02S

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart