Types of Molded Case Circuit Breakers: MCCB Guide for Engineers
Compare MCCB types including thermal-magnetic, electronic trip, motor protection, current-limiting, and DC-rated units for industrial use. Shop at Stoklink.
The Schneider Electric G12FASB2 is a set of 2 interphase barriers (phase insulators) for GoPact MCCB 125 moulded case circuit breakers, used to maximise insulation at the power-connection points. The barriers clip directly onto the breaker and measure 54 mm wide by 43 mm high, 1.4 mm thick.
G12FASB2 is an insulation accessory, not a status or control part: the clip-on barriers reduce the risk of inter-phase arcing or contact at the breaker's power terminals, and the same set of 2 serves either the upstream or downstream connection on 3-pole or 4-pole GoPact MCCB 125 breakers. It is sold as a spare part, so it is only needed if the barriers supplied with the breaker are missing or damaged, or a second set is required for the opposite end of the connection.
| Range of product | GoPact MCCB |
|---|---|
| Product or component type | Interphase barrier |
| Device application | Insulation |
| Range compatibility | GoPact MCCB 125 |
| Poles description | 3P, 4P |
| Quantity | 2 |
| Localisation on device | Upstream, Downstream |
|---|---|
| Width | 54 mm |
| Height | 43 mm |
| thickness | 1.4 mm |
| Accessory / separate part category | Spare part |
| Warranty (in months) | 18 |
|---|
| Part number | G12FASB2 |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1 cm |
| Package 1 Width | 28 cm |
| Package 1 Length | 19.5 cm |
| Package 1 Weight | 0.1 kg |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 2.8 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 149 cm |
| Package 3 Width | 60 cm |
| Package 3 Length | 80 cm |
| Package 3 Weight | 53.4 kg |
| Shipping weight | 0.1 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for G12FASB2 is 853890.
G12FASB2 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Compare MCCB types including thermal-magnetic, electronic trip, motor protection, current-limiting, and DC-rated units for industrial use. Shop at Stoklink.
Select the right MCCB with our engineer checklist covering IEC 60947-2, sizing, breaking capacity, trip units, and derating for industry. Shop at Stoklink.
IEC 60947-2 defines MCCB ratings Icu, Ics, Icw, utilization categories A and B, and type tests for low-voltage circuit breakers up to 1000V. Shop...