Types of Molded Case Circuit Breakers: MCCB Guide for Engineers
Compare MCCB types including thermal-magnetic, electronic trip, motor protection, current-limiting, and DC-rated units for industrial use. Shop at Stoklink.
The Schneider Electric EZCV250H4063 is a 63 A EasyPact EZCV250H moulded case circuit breaker with integrated earth-leakage (Vigi) protection for low-voltage distribution. Its TM-D thermal-magnetic trip unit combines overload, short-circuit and earth-fault tripping, and the 4-pole frame breaks 36 kA at 380/415 V AC under IEC 60947-2.
EZCV250H4063 folds earth-fault detection into the breaker itself rather than requiring a separate add-on Vigi module, so it suits a 4-pole distribution circuit that needs earth-leakage protection in the same DIN footprint as a standard EZCV250H breaker. The 63 A TM-D trip is fixed-thermal, so pick a different amperage in the EZCV250H4xxx line rather than relying on field adjustment if the protected circuit's load current changes. Because the 36 kA breaking figure applies at 380/415 V, verify prospective fault current at the installation point before using the 25 kA rating that applies at 440 V.
| Range of product | EasyPact |
|---|---|
| Product or component type | Circuit breaker |
| Device short name | Easypact EZCV250H |
| Circuit breaker name | Easypact EZCV250H |
| Device application | Distribution |
| Poles description | 4P |
| Protected poles description | 3t |
| Network type | AC |
| Network frequency | 50/60 Hz |
| [In] rated current | 63 A at 40 °C |
| [Ui] rated insulation voltage | 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Breaking capacity code | H |
| Breaking capacity | 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2, 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service breaking capacity | 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 63 A at 40 °C |
| Protection type | Overload protection, Short-circuit protection, Earth-leakage protection |
| Pollution degree | 3 conforming to IEC 60947 |
| Control type | Toggle |
|---|---|
| Mounting mode | Fixed |
| Mounting support | Backplate |
| Upside connection | Front |
| Downside connection | Front |
| Mechanical durability | 10000 cycles |
| Connection pitch | 35 mm |
| Local signalling | Positive contact indication |
| Neutral protection setting | Without protection |
| Earth-leakage protection | With |
| Height | 165 mm |
| Width | 140 mm |
| Depth | 68 mm |
| Standards | EN/IEC 60947-1, JIS C8201-2-2, EN/IEC 60947-2, GB/T 14048.2 |
|---|---|
| IP degree of protection | IP20 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to EN 50102 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -35…85 °C |
| Part number | EZCV250H4063 |
|---|---|
| Type designation | Easypact EZCV250H |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| Warranty (in months) | 18 |
|---|
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12.0 cm |
| Package 1 Width | 14.5 cm |
| Package 1 Length | 18.0 cm |
| Package 1 Weight | 2.52 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 15.607 kg |
| Shipping weight | 2.52 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of Easypact EZCV250H is 63 A.
The rated operational voltage of Easypact EZCV250H is 440 V AC.
The tariff (HS) code on file for Easypact EZCV250H is 853620.
Easypact EZCV250H ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Compare MCCB types including thermal-magnetic, electronic trip, motor protection, current-limiting, and DC-rated units for industrial use. Shop at Stoklink.
Select the right MCCB with our engineer checklist covering IEC 60947-2, sizing, breaking capacity, trip units, and derating for industry. Shop at Stoklink.
IEC 60947-2 defines MCCB ratings Icu, Ics, Icw, utilization categories A and B, and type tests for low-voltage circuit breakers up to 1000V. Shop...