Part number
C10S2TM040
Model no
NSX100S
719.54 SR On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric C10S2TM040 ComPacT NSX100S 2P 40 A 70 kA TM-D Fixed Moulded Case Circuit Breaker

Schneider Electric NSX100S 2P 40 A, 70 kA Icu at 415 V AC, TM-D trip unit.

Rated current
40 A
Rated operational voltage
690 V AC
Description

About the NSX100S

The Schneider Electric C10S2TM040 is a ComPacT NSX100S molded case circuit breaker built for distribution circuits. Configured as 2P, it is rated for 40 A continuous current with a 70 kA breaking capacity (Icu) at 415 V AC, and carries a TM-D thermal-magnetic trip unit for overload and short-circuit protection (LI). The breaker also carries a DC rating for 500 V circuits.

Certifications & Standards

  • EN/IEC 60947-2

Selection Notes

The C10S2TM040 uses a fixed TM-D trip unit on the NSX100S frame (a high breaking-capacity frame with extended DC ratings): both the thermal pick-up (1 x In) and the magnetic instantaneous threshold are set at the factory, so there are no adjustments to make or verify on site. That fixed setting suits a final circuit sized directly to the 40 A load it protects. The 70 kA Icu at 415 V AC is the figure to check against the prospective fault current at the installation point before specifying this frame over a higher-breaking-capacity one. It is also rated Yes for isolation duty under EN/IEC 60947-2, so it can serve as the local disconnecting means for the circuit it protects.

Specification

Full specification

83 values · Last verified 30 Oct 2026

Main 20

Range ComPacT
Product name ComPacT NSX
Device short name NSX100S
Product or component type Circuit breaker
Device application Distribution
Poles description 2P
Protected poles description 2D
[In] rated current 40 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz, 500 V DC
Network type AC, DC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
Breaking capacity 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 35 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2, 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 250 V DC 1 pole conforming to IEC 60947-2, 100 kA Icu at 500 V DC 2 poles in series conforming to IEC 60947-2, 100 kA Icu at 500 V DC 2P conforming to IEC 60947-2
Breaking capacity code S 70 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed

Complementary 23

[Ui] rated insulation voltage 750 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
[Ics] rated service breaking capacity 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 35 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2, 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA at 250 V DC conforming to IEC 60947-2, 100 kA at 500 V DC conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 277 V In/2, 10000 cycles at 277 V In
Power dissipation per pole 5.47 W
Mounting support Backplate
Mounting position Horizontal and vertical, Flat on the back
Upside connection Front
Downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal), I : for short-circuit protection (magnetic)
Trip unit rating 40 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Fixed
[Ir] long-time protection pick-up adjustment range 1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 500 A
Earth-leakage protection Without
Width (W) 70 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 1.2 kg

Environment 10

Standards EN/IEC 60947-2
Overvoltage category III
Electrical shock protection class Class II on front face
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating, 2000 m...5000 m with derating
Show all 83 specifications ↓ Show less ↑30 more values in Identification, Contractual warranty, Logistics.

Identification 7

Part number C10S2TM040
Type designation NSX100S
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production

Contractual warranty 1

Warranty (in months) 18

Logistics 22

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.000 cm
Package 1 Width 13.000 cm
Package 1 Length 18.000 cm
Package 1 Weight 1.281 kg
Unit Type of Package 2 S03
Number of Units in Package 2 12
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 15.792 kg
Unit Type of Package 3 P12
Number of Units in Package 3 96
Package 3 Height 45.000 cm
Package 3 Width 80.000 cm
Package 3 Length 120.000 cm
Package 3 Weight 138.336 kg
Shipping weight 1.2 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for C10S2TM040

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • EN/IEC 60947-2
Quick answers

Questions about the NSX100S

What is the rated current of NSX100S?

The rated current of NSX100S is 40 A.

Which supply voltage is NSX100S rated for?

The rated operational voltage of NSX100S is 690 V AC.

What is the HS code of NSX100S for customs?

The tariff (HS) code on file for NSX100S is 853620.

Where does NSX100S ship from, and how fast?

NSX100S ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for MCCB

All guides for MCCB
Reviews

Customer reviews

Series

Schneider Electric Schneider ComPacT NSX

Brand
Schneider Electric
Series
Schneider ComPacT NSX
Series page →
Series

Other series in Molded Case Circuit Breakers (MCCB)

719.54 SR On request
Get a Quote
Quote

Get a Quote

NSX100S

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · C10S2TM040

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart